Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 16 - 16
1 Jun 2015
Ghosh K Quayle J Nawaz Z Stevenson T Williamson M Shafafy R Chissell H
Full Access

Difficulties arise when counselling younger patients on the long-term sequelae of a minor knee chondral defect. This study assesses the natural history of patients with grade 2 Outerbridge chondral injuries of the medial femoral condyle at arthroscopy. We reviewed all arthroscopies performed by one surgeon over 12 years with Outerbridge grade 2 chondral defects. Patients aged 30 to 59 were included. Meniscal injuries found were treated with partial menisectomy. All patients had five-year follow up minimum. Primary outcome measure was further interventions of total or unicondylar arthroplasty or high tibial osteotomy. We analysed 3,344 arthroscopies. Average follow up was 10 years (Range 5–17 years). A total of 357 patients met inclusion criteria of which 86 had isolated medial femoral condyle disease. Average age was 50 at the time of arthroscopy. Average BMI at surgery was 31.7 and average chondral defect area was 450 mm2. Isolated MFC chondral disease had a 10.5% intervention rate. Intervention occurred at a mean of 8.5 years post primary arthroscopy. In young patients Outerbridge II chondral injuries affecting ≥2 compartments have a high rate of further intervention within a decade. This information is crucial in counselling young patients on long-term sequelae of benign chondral lesions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 43 - 43
1 Jun 2012
Dhinsa B Jalgaonkar A Nawaz Z Briggs T Muirhead-Allwood S Carrington R Skinner J Bentley G Miles J
Full Access

Patients with osteochondrodysplasia frequently require Total Hip Arthroplasty at a younger age, as a result of early degenerative disease of the hip joint. The outcome of Modular Total Hip Arthroplasty in this group of patients has been reported previously. In this retrospective study we evaluated the outcome of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia.

Between 1974 and 2009, twenty one CADCAM Total Hip Arthroplasty procedures were performed in fourteen patients in our institution. There were eight female and six male patients, with the mean age at time of surgery of 40.95 years (20 to 78). The patients were followed up clinically and with the Harris hip score for a mean of 7.12 years (0.5 to 17 years).

Four of the twenty-one hips (23.8%) required revision surgery at a mean of 11.54 years (6.5 to 17 years); one required it for aseptic loosening of the femoral component; one required complete revision of the acetabular component; one required exchange of acetabular liner; and one was for symptomatic non-union of a lesser trochanter avulsion.

This study shows encouraging clinical outcomes of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia,


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 44 - 44
1 Jun 2012
Dhinsa B Nawaz Z Gallagher K Carrington R Skinner J Briggs T Bentley G
Full Access

Purpose

The rate of arthroplasty or osteotomy in patients who had undergone autologous chondrocyte implantation (ACI) for osteochondral defects in the knee was determined. Furthermore, we investigated whether any radiographic evidence of osteoarthritis (OA) prior to ACI was associated with poorer outcome following surgery.

Methods

We retrospectively reviewed the medical notes and radiographs of 236 patients (mean age 34.9) who underwent ACI from 1998 to 2005 at our institution. Knee function was assessed according to the Modified Cincinnati Score (MCS) pre-operatively and at a mean of 64.3 months postoperatively (range 12 – 130). Radiographic changes were graded according to the Stanmore grading system.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 45 - 45
1 Jun 2012
Dhinsa B Gallagher K Nawaz Z Spiegelberg B Hanna S Tai S Pollock R Carrington R Cannon S Briggs T
Full Access

The aim of this study is to investigate whether Metal-on-Metal (MoM) implants result in more chromosome aberrations and increased blood metal ions post-operatively when compared to Metal-on-Polyethylene (MoP) implants. Metal-on-metal arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirement for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants. This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hybridisation (FISH). 53 patients have been recruited to date. 24 of whom had MoP prosthesis and 29 a MoM. 37 of these have had their one year follow-up with blood analysis and 14 have had 2 year follow up. Cobalt and chromium concentration increased during the first 6 months in both MoM and MoP groups, in the MoM group the chromium levels were twice that of MoP group and 12x that of the preoperative samples. Chromosome aberrations occurred in both groups. At 6 months both the MoM and MoP groups showed increase frequency of aneuploidy aberrations with further increases after one year. Structural damage in the form of translocations occurred in the MoM group after one year, but not in the MoP group, by two years there was a profound increase in translocations Preliminary results of this study show that the levels of chromium and cobalt are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations in the groups with increases in structural chromosome damage after two years.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 92 - 92
1 May 2011
Parratt M Nawaz Z Gikas P Carrington R Skinner J Bentley G Briggs T
Full Access

High tibial osteotomy (HTO) is a recognised method of correction for knee joint malalignment and unicompartmental osteoarthritis. The long term results of this technique have been reported and are favourable. Autologous chondrocyte implantation (ACI-C, MACI) has also been reported to have good results It is advised that malalignment, if present, should be corrected if ACI is to be performed. Although results have been reported for either procedure separately, the outcomes of combined HTO-ACI remain unreported.

To evaluate functional outcome in a group of patients undergoing combined HTO-ACI procedures.

Twenty three patients undergoing a combined ACI-HTO procedure were identified retrospectively from a larger trial of patients undergoing ACI for symptomatic chondral defects. The mean follow-up was 54 months (range 12 – 108) and the mean defect size was 689 mm2 (range 350 – 1200). Nine patients had ACI-C and HTO, the remainder having MACI and HTO. Pre and postoperative assessment was carried out using the Visual Analogue Score (VAS), the Bentley Functional Rating Score and the Modified Cincinnati Rating System.

The Mean VAS score improved from 7.4 pre-operatively to 2.9 post-operatively (p< 0.0001). The Bentley Functional Rating Score improved from 2.9 to 1.8 (p< 0.0001) whilst the Modified Cincinnati Rating System improved from 35.2 pre-operatively to 68.7 post-operatively (p< 0.0001). There was no significant difference between ACI-C and MACI. Two patients developed a non union at a mean of 13 months and a further two patients had a failure of the chondrocyte graft at a mean of 22.5 months.

Combining high tibial osteotomy with autologous chondrocyte implantation is an effective method of decreasing pain and increasing function at mean of 54 months follow-up. Further follow-up is required to assess the long term outcomes of these combined procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 307 - 314
1 Mar 2011
Matthies A Underwood R Cann P Ilo K Nawaz Z Skinner J Hart AJ

This study compared component wear rates and pre-revision blood metal ions levels in two groups of failed metal-on-metal hip arthroplasties: hip resurfacing and modular total hip replacement (THR).

There was no significant difference in the median rate of linear wear between the groups for both acetabular (p = 0.4633) and femoral (p = 0.0872) components. There was also no significant difference in the median linear wear rates when failed hip resurfacing and modular THR hips of the same type (ASR and Birmingham hip resurfacing (BHR)) were compared.

Unlike other studies of well-functioning hips, there was no significant difference in pre-revision blood metal ion levels between hip resurfacing and modular THR.

Edge loading was common in both groups, but more common in the resurfacing group (67%) than in the modular group (57%). However, this was not significant (p = 0.3479). We attribute this difference to retention of the neck in resurfacing of the hip, leading to impingement-type edge loading. This was supported by visual evidence of impingement on the femur.

These findings show that failed metal-on-metal hip resurfacing and modular THRs have similar component wear rates and are both associated with raised pre-revision blood levels of metal ions.