In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique.
In tissue engineering, scaffolds are vitalized by cells in vitro. Human mesenchymal stem cells (hMSC) are very interesting because of their ability to differentiate towards the osteogenic lineage and their self renewing capacity. Yet, it is important that implanted cells do not disseminate and exhibit unwanted cell growth outside the implantation site. Therefore the aim of this study was to detect migrated cells in organs of mice after implantation of a composite (cell-scaffold) substitute. HMSC (Cambrex, USA) were inoculated on a clinically approved 3D scaffold (Tutobone(TM), Tutogen, Germany). One composite and one scaffold without cells were implanted subcutanously, left and right paravertebrally in athymic nude mice (nu/nu). After 2, 4, 8 and 12 weeks constructs were explanted and organs (liver, spleen, lungs, kidney, heart, testicles, brain and blood) were harvested. The entire organs were homogenized and genomic DNA was isolated for qualitative and quantitative PCR. Human DNA was found in all explanted composites at all examined time points. No human DNA could be detected in control scaffolds. Moreover we did not detect human DNA in all explanted organs at any time point. As internal controls we could detect 1 single hMSC in a pool of 106 mouse cells. In conclusion, we could proof that cells of implanted composite substitutes do not migrate to other organs. Furthermore, this study showed that implanted hMSC seeded on 3D scaffolds survive over time frames up to 12 weeks.
Ollier’s disease is characterised by severe deformity of the extremities and retarded growth because of multiple enchondromas. For correction of deformity, the Ilizarov method has been used although it has many complications. A 17-year-old boy with Ollier’s disease had a limb-length discrepancy of 17.4 cm, with a valgus deformity of the right knee and recurvatum of the femur of 23°. He had undergone three unsuccessful attempts to correct the deformities by using external fixators. We used a fully implantable, motorised, lengthening and correction nail (Fitbone) to achieve full correction of all the deformities without complications. We decided to carry out the procedure in three stages. First, we lengthened the femur by 3.6 cm and the tibia by 4 cm. We then exchanged the femoral nail for a longer implant and achieved a further 6 cm of length. This reduced the shortening to 3.8 cm. When the boy has finished secondary school we will adjust the remaining discrepancy.
We report the case of a 22-year-old woman who underwent plate and screw fixation for a traumatic left acetabular fracture and fixation with cancellous screws for an associated femoral neck fracture. Two months later, the internal fixation became infected and was removed. This resulted in a painful high dislocation of the hip. We solved the problem with continuous soft-tissue distraction using a fully implantable motorised distraction nail in order to reduce the proximal femur prior to total hip arthroplasty. To our knowledge, this is the first time that reduction of a high dislocation of the hip has been performed using such a system.