Pre-operative anaemia can present in up to 30% of elective arthroplasty patients. The presence of anaemia increases the risk of requiring blood transfusion post-operatively as well as acts as an independent risk factor for poor outcome such as prosthetic joint infection. Recent international consensus on this topic has recommended a specific care pathway for screening patients with pre-operative anaemia using a simple bedside Heaemacue finger-prick test to detect in a simple and cost-effective manner, and then allow treatment of preoperative anaemia. This pathway was therefore incorporated in our trust. This was a retrospective study done at a single tertiary-referral arthroplasty centre. Our data collection included the Heamacue test results and formal haemoglobin levels if they were performed as well as compliance and costs of each of the tests for patients listed for an elective shoulder, hip and knee arthroplasty between September and December 2018. Medical records and demographics were also collected for these patients for subgroup analysis. Our exclusion criteria comprised patients listed for revision arthroplasty surgery. 87 patients were included in this study. Our compliance rate was 15%. The mean difference between a Haemacue test and a formal FBC result was only 17.6g/L suggesting that it has a reasonably high accuracy. With regards to costs, we found that a Haemacue test costs £2, compared to £7.50 for a full blood count and Haematinics combined. This gave an overall cost saving of £5.50 per patient. Extrapolation of this date locally for 2017 at our hospital, where 1575 primary joint arthroplasties were done, a cost saving of £8,662.5 could have been achieved. Within the UK using data extrapolated from the National Joint Registry a total of £1,102,205.5 (1,221,894 Euros) could have been saved. The use of a single, Haemacue test to screen for pre-operative anaemia in elective arthroplasty patients is more cost effective compared to a formal full count and haematinics tests. However, we found that compliance with the care pathway is variable due to system limitations. This may be addressed through implementing changes to our electronic system in which patients are booked for surgery. We also noted a significant cost reduction if this pathway were to be used Nation-wide. Thus, we encourage other centres to consider the use of the Haemacue test pre-operatively in elective arthroplasty instead of formal full blood counts at the time of decision to treat with arthroplasty; this allows sufficient time for correction of pre-operative anaemia thus improving patient outcomes from arthroplasty.
1. To investigate the effect of revision total knee replacement (TKR) on gait kinematics in patients with a primary TKR and instability.2. To compare gait kinematics between patients with a well-functioning TKR and those with a primary TKR and symptoms of instability. This single-centre observational study is following patients who have had a revision TKR due to knee instability. Data was collected pre- and post-operatively at 8–12 week follow-up. The data was compared to a control group of 18 well-functioning TKR patients. Kinematic gait data was collected during routine clinics using a treadmill-based infrared 3D system (Vicon, Oxford, UK) and a published lower limb marker-set. Patients performed 15 strides at three different speeds: 0.6mph, self-selected, and a ‘slow walk’ normalised to leg length (Froude number 0.09). PROMs questionnaires were collected. NHS ethical approval was obtained.Abstract
Objectives
Methods
Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the Thompson implant when performing hip hemiarthroplasty and recommended surgeons consider using the anterolateral surgical approach over a posterior approach. Our objective was to review outcomes from a consecutive series of Thompson hip hemiarthroplasty procedures performed in our unit and to identify any factors predicting the risk of complications. 807 Thompson hip hemiarthroplasty cases performed between April 2008 and November 2013 were reviewed. 721 (89.3%) were cemented and 86 (10.7%) uncemented. 575 (71.3%) were performed in female patients. The anterolateral approach was performed in 753 (93.3%) and the posterior approach with enhanced soft tissue repair in 54 (6.7%). Overall, there were 23 dislocations (2.9%). Dislocation following the posterior approach occurred in 13.0% (7 of 54) in comparison to 2.1% (16 of 753) with the anterolateral approach (odds ratio (OR) 8.5 (95% CI 2.8 to 26.3) p < 0.001). Surgeon grade and patient history of cognitive impairment did not have a significant impact on dislocation rate. Patients were discharged home in 459 cases (56.9%), to a care home or other hospital in 273 cases (33.8%). 51.8% (338 of 653) returned home within 30 days. 75 died during their admission (9.3%). 30-day mortality was 7.1% and 1-year mortality was 16.6%. Intraoperative fracture occurred in 15 cases (1.9%) of which 14 were cemented. Superficial or deep infection occurred in 33 cases (4.1%). We recommend against the continued use of the posterior approach in hip hemiarthroplasty, as enhanced soft tissue repair did not reduce dislocation rates to an acceptable level. Our findings, however, demonstrate satisfactory results for patients treated with the Thompson hip hemiarthroplasty performed through an anterolateral approach. We suggest that the continued use of the Thompson implant in a carefully selected patient cohort is justifiable.