Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 21 - 21
16 May 2024
Morrell R Abas S Kakwani R Townshend D
Full Access

Background

The use of a knotless TightRope for the stabilisation of a syndesmotic injury is a well-recognised mode of fixation. It has been described that the device can be inserted using a “closed” technique. This presents a risk of saphenous nerve entrapment and post-operative pain.

Aim

We aimed to establish the actual risk of injury to the Saphenous Nerve using a “closed” technique for the insertion of a TightRope.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 197 - 197
1 Sep 2012
Jensen C Morrell R Steval A Partington P Reed M Muller S
Full Access

Introduction

Rivaroxaban has been recommended for routine use as a thromboprophylactic agent in patients undergoing lower limb arthroplasty. Trials supporting its use have not fully evaluated the risks of wound complications related to rivaroxaban.

Method

A retrospective cohort analysis of 1558 consecutive patients who underwent total hip or knee replacements within the same hospital during a 19 month period (2009–2010) was performed. The first 489 patients (Group 1) were given tinzaparin postoperatively as per NICE guidance. The following 559 patients (Group 2) were given rivaroxaban. Concerns regarding wound complications prompted a change back to tinzaparin for the next 510 patients (Group 3.) Other than the thromboprophylactic agent used there were no other differences in the pre and postoperative treatments of all these patients.