header advert
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 65 - 65
1 Apr 2019
Mooney J Huddleston J Amanatullah D
Full Access

Computer-assisted orthopaedic surgery (CAOS) improves mechanical alignment and the accuracy of surgical cuts in the context of total knee arthroplasty. A simplified, CAOS enhanced instrumentation system was assessed to determine if the same effects could be achieved through the use of a less intrusive system. Two cohorts of surgeons (experienced and trainees) performed a series of total knee arthroplasty resections in knee models with and without navigation-enhanced instrumentation. The percentage of resections that deviated from the planned cut by more than 2°or 2mm (outliers) was determined by post-resection advanced imaging for six unique outcome metrics. Within each experience level, the use of the CAOS enhanced system significantly reduced the total percentage of outliers as compared to conventional instrumentation (Figure 1). The experienced users improved from 35% to 4% outliers overall (p < .001) and the trainees from 34% to 10% outliers (p < .001). Comparing across experience levels, the experienced surgeons performed significantly better in only a single resection metric with conventional instrumentation (Figure 2A), varus/valgus tibial alignment, with 8.3% outliers compared to the trainee's 63% outliers (p = .004). The use of CAOS enhanced instrumentation eliminated any differences between the two user groups for all measured resections (Figure 2B). Comparing CAOS enhanced to conventional instrumentation specifically between anatomical deformity types revealed that there is significant improvement (p < .05) with the use of enhanced instrumentation for all three deformity types (Figure 3). These results suggest that non-intrusive CAOS enhanced instrumentation is a viable alternative to conventional instrumentation with possible benefits. This trial also demonstrates that additional experience may not correlate to improved surgical accuracy, and outliers may be less a result of individual surgeon ability or specific anatomic deformities, and more so related to limitations of the instrumentation used or other yet unidentified factors.