header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2022
Mohammed R Shah P Durst A Mathai N Budu A Trivedi R Francis J Woodfield J Statham P Marjoram T Kaleel S Cumming D Sewell M Montgomery A Abdelaal A Jasani V Golash A Buddhiw S Rezajooi K Lee R Afolayan J Shafafy R Shah N Stringfellow T Ali C Oduoza U Balasubramanian S Pannu C Ahuja S
Full Access

Abstract

Aim

With resumption of elective spine surgery services following the first wave of COVID-19 pandemic, we conducted a multi-centre BASS collaborative study to examine the clinical outcomes of surgeries.

Methods

Prospective data was collected from eight spinal centres in the first month of operating following restoration of elective spine surgery following the first wave. Primary outcomes measures were the 30-day mortality rate and postoperative Covid-19 infection rate. Secondary outcomes analysed were the surgical, medical adverse events and length of inpatient stay.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 21 - 21
1 Sep 2021
Shah P Rajesh M Sedra F Aftab S Nadarajah R Montgomery A Ranganathan A
Full Access

Introduction

Traditionally correction of idiopathic paediatric scoliosis is done by hybrid fixation. This involves a judicious combination of mono-axial and poly-axial screw constructs. This has inherent perceived advantages with better deformity correction and maintaining alignment without loss of correction over time.

Study design

Single centre retrospective review of prospective collected data on the radiological analysis of idiopathic paediatric scoliosis corrections. The study compared hybrid screw constructs (poly-axial & mono-axial) to all poly-axial screw constructs over 28 months.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 92 - 92
1 Mar 2021
Taha R Davis T Montgomery A Karantana A
Full Access

Abstract

Objectives

1. To describe the epidemiology of metacarpal shaft fractures (MSF) in adults. 2. To evaluate the variation in practice and document complications following usual care. 3. To explore factors associated with treatment modality. 4. To document hospital resource use following MSF.

Methods

A multi-centre, retrospective, cross-sectional study of MSF at six centres. The healthcare records, operative notes and imaging of adults presenting within 10 days of a MSF, affecting the second to fifth metacarpal between 1st August 2016 to 31st July 2017, were reviewed. Total number of Emergency Department (ED) attendances were used to calculate prevalence. Data analyses are primarily descriptive with 95% confidence intervals to quantify uncertainty in estimates.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 216 - 216
1 Jul 2008
Venkateswaran B Montgomery A Zaman T Even T Copeland S Levy O
Full Access

The purpose of this study is to report the 1 to 5 year results of arthroscopic Rotator Cuff repairs.

Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up. Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded.

The mean follow up time was 23.8 months (range 12–61). Mean age was 57.3 years (range 23–78). 47% had a history of trauma. There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small. Isolated Supraspinatus (SSP) tear was recorded in 83.5% and subscapularis tear in 7 %. A combination of SSP tear with infraspinatus and teres minor was found in 9.6%.

86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair.

The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 re-tears (19.6%). eight of the 102 patients were not satisfied. Five of these patients had revision operation.

Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results with 20% re-tear rate, while offering all the advantages of arthroscopic surgery.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 345 - 345
1 May 2006
Levy O Venkateswaran B Montgomery A Zaman T Even T Copeland S
Full Access

Arthroscopic Rotator cuff repair is gaining popularity in recent years; however, the results of arthroscopic repairs are yet to be reported. Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up.

The mean follow up time was 23.8 months (range 12–61). There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small.

Mean age was 57.3 years (range 23–78). 47% had a history of trauma.

Mainly Supraspinatus (SSP) tear was recorded in 83.5% and isolated subscapularis tear in 7%. A combination of SSP tear with infraspinatus and teres minor minor (posterior tear) was found in 9.6%.

86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair.

Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded.

The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 ultrasound demonstrated re-tears (19.6%). However, the majority of patients with radiological re-tears had good function, pain relief and were satisfied. Eight of the 102 patients were not satisfied. Five of these patients had revision operation.

Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results while offering all the advantages of arthroscopic surgery.