Vol. 94-B, Issue SUPP_XXXVIII | Pages 137 - 137
1 Sep 2012
Duffy PJ Gray A Powell J Mitchell J Tyberg J
Full Access

Purpose

There are concerns with regard to the physiological effects of reamed intramedullary femoral fracture stabilisation in patients who have received a pulmonary injury. This large animal study used invasive monitoring techniques to obtain sensitive cardiopulmonary measurements and compared the responses to Early Total Care (reamed intramedullary femoral fracture fixation) to Damage Control Orthopaedics (external fixation), after the induction of acute lung injury. We hypothesised a greater cardiopulmonary response to intramedullary fracture fixation.

Method

Acute lung injury (PaO2/FiO2 < 200 mmHg) was induced in 12 invasively monitored and terminally anaesthetised male sheep via the infusion of oleic acid into the right atrium. Each animal underwent surgical femoral osteotomy and fixation with either reamed intramedullary (n=6) or external fixation (n=6). Simultaneous haemodynamic and arterial blood-gas measurements were recorded at baseline and at 5, 30 and 60 minutes after fracture stabilisation.