Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 10 - 10
1 Mar 2014
Lynch J Walker R Norton M Middleton R
Full Access

Routine postoperative radiographs following hip hemiarthroplasty are commonly undertaken despite it being suggested that they can cause delays to discharge, discomfort to patients and unnecessary radiation. Our study considered the necessity of these post-operative radiographs.

A retrospective search was conducted of all hemiarthroplasty procedures on the Royal Cornwall Hospital database. These were reviewed for cases where re-operation was conducted within 6 weeks. Notes and post-operative check radiographs of those who underwent re-operation were reviewed to determine how essential radiographs were in diagnosing complications requiring re-operations.

A total of 1557 hemiarthroplasty operations were identified. There were 37 incidences of re-operation within 6 weeks. 29 cases had normal check radiographs. 8 dislocations were picked up on post-operative radiographs. In all but one of these cases, clinical suspicion of complication had been raised prior to the radiograph. In the remaining case documentation was poor and no firm conclusion as to clinical suspicion could be drawn.

Our review of over 1500 hemiarthroplasty cases, demonstrated one incident where the check radiograph solely diagnosed an abnormality needing intervention that might not have been apparent clinically. We thus suggest that check radiographs following hip hemiarthroplasty should not be routinely ordered for all patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 186 - 186
1 Mar 2013
Jassim S Patel S Wardle N Tahmassebi J Middleton R Shardlow D Stephen A Hutchinson J Haddad F
Full Access

Introduction

In Total Hip Arthroplasty (THA), polyethylene wear reduction is key to implant longevity. Oxidized Zirconium (OxZi) unites properties of a ceramic bearing surface and metal head, producing less wear in comparison to standard Cobalt-Chromium (CoCr) when articulating with Cross-linked polyethylene (XLPE) in vitro. This study investigates in vivo polyethylene (PE) wear, outcomes and complications for these two bearing couples in patients at 5 year follow-up

Methods

400 patients undergoing THA across four institutions were prospectively randomised into three groups. Group I received a cobalt-chrome (CoCr) femoral head/ cross-linked polyethylene (XLPE) liner; Group II received an OxZi femoral head/ ultrahigh molecular weight polyethylene (UHMWPE) liner; Group III received an OxZi femoral head/XLPE liner. All bearing heads were 32 mm. Linear wear rate was calculated with Martell computer software. Functional outcome and complications were recorded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 122 - 122
1 Jan 2013
Venkatesan M Uzoigwe C Middleton R Young P Burnand H Smith R
Full Access

Background and Purpose

Serum lactate has been shown to be an indicator of adverse clinical outcomes in patients admitted secondary to general trauma or sepsis. We retrospectively investigated whether admission serum venous lactate can predict in-hospital mortality in patients with hip fractures.

Method and Results

Over a 38-month period the admission venous lactate of 807 patients with hip fractures was collated. Mean age was 82 years. The overall in-hospital mortality for this cohort was 9.4%. Mortality was not influenced by the fracture pattern or the type of surgery - be it internal fixation or arthroplasty (p = 0.7). A critical threshold of 3 mmol/L with respect to the influence of venous lactate level on mortality was identified. Mortality rate in those with a lactate level of less than 3 mmol/L was 8.6% and 14.2% for those whose level was 3 mmol/L or greater. A 1 mmol/L increase in venous lactate was associated with a 1.2 (1.02–1.41) increased risk of in-hospital mortality. Patients with a venous lactate of 3 mmol/L or higher had twice the odds of death in hospital compared to matched individuals. There was no statistically significant difference in ASA distribution between those with a lactate of less than or greater than 3 mmol/L.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 198 - 198
1 Jan 2013
Alvand A Jackson W Khan T Middleton R Gill H Price A Rees J
Full Access

Introduction

Motion analysis is a validated method of assessing technical dexterity within surgical skills centers. A more accessible and cost-effective method of skills assessment is to use a global rating scale (GRS). We aimed to perform a validation experiment to compare an arthroscopic GRS against motion analysis for monitoring orthopaedic trainees learning simulated arthroscopic meniscal repairs.

Methods

An arthroscopic meniscal repair task on a knee simulator was set up in a bioskills laboratory. Nineteen orthopaedic trainees with no experience of meniscal repair were recruited and their performance assessed whilst undertaking a standardized meniscal repair on 12 occasions. An arthroscopic GRS, assessing parameters such as “depth perception,” “bimanual dexterity,” “instrument handling,” and “final product analysis” was used to evaluate technical skill. Performance was assessed blindly by watching video recordings of the arthroscopic tasks. Dexterity analysis was performed using a motion analysis tracking system which measured “time taken,” “total path length of the subject's hands,” and “number of hand movements”.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 18 - 18
1 Sep 2012
Middleton R Vasukutty N Young P Matthews E Uzoigwe C Minhas T
Full Access

Large studies have reported high dislocation rates (7 to 24%) following revision total hip arthroplasty (THA), particularly when the revision is undertaken in the presence of pre-existing instability. We retrospectively reviewed the clinical and radiographic outcome of 155 consecutive revision THA's that had been performed using an unconstrained dual-mobility acetabular implant. It features a mobile polyethylene liner articulating with both the prosthesis head and a metal acetabular cup, such that the liner acts as the femoral head in extreme positions. It can be implanted in either a press fit or cemented manner. Mean follow-up was 40 months (18–66) and average age 77 (42–89). Uncemented (n=122) and cemented (n=33) implants with a reinforcing cage, were used. Indications were aseptic loosening (n=113), recurrent instability (n=29), periprosthetic fracture (n=11) and sepsis (n=2). Three of the 155 cases (1.9%) dislocated within 6 weeks of surgery and were successfully managed with closed reduction. The 3 dislocations occurred in the groups revised for recurrent dislocation and periprosthetic fracture. There were no cases of recurrent dislocation and no revisions for implant failure. Despite a pantheon of options available, post-operative dislocation remains a challenge especially in patients with risk factors for instability. The use of large diameter heads is proven to improve stability but there are concerns regarding wear rates, metal toxicity and recurrent dislocation in the presence of abductor dysfunction. With constrained liners there are concerns regarding device failure and aseptic loosening due to implant overload. Our dislocation rates of 1.9% and survivorship to date compare favourably with alternative techniques and are also in line with studies from France using implants of a similar design. In our hands, where there are risk factors for dislocation, the use of a dual-mobility implant has been very effective at both restoring and maintaining stability in patients undergoing revision THA.