Solid or cystic pseudotumour is a potentially destructive complication of metal on metal (MoM) couples, usually needing revision surgery. However, complete clearance of the pseudotumour is unlikely at times. This prospective case-controlled study reports cases which had recurrence after revision surgery for pseudotumour related to metal on metal hip couples. A total of 37 hips (33 MoM hip resurfacing and four big head MoM total hip arthroplasty (THA)) were revised for pseudotumour during the last 10 years. The patient demographics, time to revision, cup orientation, operative and histological findings were recorded for this cohort. Patients were divided into two groups - group R (needing re-revision for disease progression) and group C (control - no evidence of disease progression). Oxford hip scores (OHS, 0–48, 48 best outcome) were used to assess clinical outcome. The diagnosis of disease progression was based on recurrence of clinical symptoms, cross-sectional imaging, operative and histological findings.Introduction
Methods
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05.Introduction
Methods
Establishing a full-thickness cartilage in the lateral compartment and functionally intact ACL is vital before proceeding with unicompartmental knee replacement (UKR). The aim of this study is to assess whether MRI is a useful adjunct in predicting suitability for UKR, as compared to standard and stress radiographs. We identified 50 patients with a knee found suitable for UKR based on their standard and stress radiographs (full-thickness cartilage on lateral side). These patients underwent an additional cartilage-specific MRI scan to identify the status of ACL and the lateral compartment. The final decision regarding the suitability for UKR was based on the intra-operative observation.INTRODUCTION
METHODS
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05. Preliminary analysis showed that total head DIMM was significantly (p = 0.02) greater for CoCr (0.97mm ± 0.6mm) than stainless steel (0.27mm ± 0.6mm). The mean stem bending for CoCr was 0.08mm (± 0.06mm) and for stainless steel 0.15mm (± 0.06mm) (p =0.77). Both implants heads migrated posteriorly, medially and distally. The mean subsidence for the cobalt-chromium and stainless steel stems was 1.02mm (± 0.19mm) (p < 0.001) and 1.12mm (± 0.34mm) (p=0.001) (p= 0.07) at 24 months. It was interesting to note that the dynamically induced micromotion was greater for the stiffer stem, however there were no differences in terms of overall migration, indicating that survival (in terms of loosening) should be the similar for both steel and CoCr versions of this implant.