Biomechanical alignment of the knee is a major determinant in the outcome of Total Knee Arthroplasty. However, the best method to assess the alignment is yet undecided. Conventional methods use hip to ankle “long” standing x-rays but these suffer from technical difficulties and hence are a potential for error. Short x-rays are considered to have doubtful accuracy. This study aimed to assess if the “short” AP x-rays could be used to assess the lower limb axis within a range of statistically insignificant and clinically acceptable difference. The results indicate the readings from the short x-rays were not statistically different from those obtained from the long x-rays in four sets of observations. The largest difference between any two readings was 0.68 degrees. The analysis of data showed that the measurements from the short x-rays could indeed be used to assess the long axis of the lower limb with the provison that there is no gross femoral shaft deformity.
To report and validate the early migration rates of the collarless polished tapered hip replacement using manual and computer measurements To report early clinical results of the CPT hip
There was no significant difference between inter or intra observer measurements for hip migration. This is the first study to date that we are aware of that describes the subsidence rates of the CPT hip which includes validation by inter and intra observer readings.
Tibiofemoral alignment has a direct correlation with the survival of total knee arthroplasty. Traditionally, it has been measured using a goniometer on radiographs. We describe new software which measures this alignment on scanned radiographs by automatically detecting bones in the image. Two surgeons used conventional methods and two clerical officers used the computerised routine to assess 58 radiographs of the knee on two occasions. There were no significant differences between any of the paired comparisons. The largest mean difference detected was 1.19°. Across all comparisons, the mean correlation was 0.755. A standardised routine for measuring tibiofemoral alignment was the greatest factor in reducing error in our study. These results show that non-medical staff can reliably use the software to measure tibiofemoral alignment. It has the potential to measure all the parameters recommended by the Knee Society.
We describe a method of audit of a type of total knee replacement, including some details of the organisational difficulties of administering multicentre studies, and draw attention to how this can be done using industrial funding without prejudicing the study. This is a prospective record of 1439 patients who had an Insall-Burstein II (IBII) prosthesis implanted between 1990 and 1994. The data were collected using the American Knee Society scoring system. A method of storing radiographs digitally at low cost is also described. The results emphasise the need for the long-term collection of data on commonly used devices implanted by a cross-section of surgeons. We conclude that for most patients the IBII cemented, posteriorly stabilised, cruciate-substituting prosthesis will relieve pain and give excellent functional results throughout the patients’ remaining years with a very small incidence of revision, except in cases of infection.