Supination-external rotation (SER) injuries make up 80% of all ankle fractures. SER stage 2 injuries (AITFL and Weber B) are considered stable. SER stage 3 injury includes disruption of the posterior malleolus (or PITFL). In SER stage 4 there is either medial malleolus fracture or deltoid injury too. SER 4 injuries have been considered unstable, requiring surgery. The deltoid ligament is a key component of ankle stability, but clinical tests to assess deltoid injury have low specificity. This study specifically investigates the role of the components of the deep deltoid ligament in SER ankle fractures. To investigate the effect of deep deltoid ligament injury on SER ankle fracture stability.Background
Aim
Osteoporosis is a disease when bone mass and tissue is lost, with a consequent increase in bone fragility and increase susceptibility to develop fracture. The osteoporosis prevalence increases markedly with age, from 2% at 50 years to more than 25% at 80 years1 in women. The vast majority of distal radius fractures (DRFs) can be considered fragility fractures. The DRF is usually the first medical presentation of these fractures. With an aging population, all fracture clinics should have embedded screening for bone health and falls risk. DRF is the commonest type of fracture in perimenopausal women and is associated with an increased risk of later non-wrist fracture of up to one in five in the subsequent decade2. According to the national guidelines in managing the fragility fractures of distal radius with regards the bone health review, we, as orthopedic surgeons, are responsible to detect the risky patients, refer them to the responsible team to perform the required investigations and offer the treatment. We reviewed our local database (E-trauma) all cases of fracture distal radius retrospectively during the period from 01/08/2019 to 29/09/2019. We included total of 45 patients who have been managed conservatively and followed up in fracture clinic. Our inclusion criteria was: women aged 65 years and over, men aged 75 years and over with risk factors, patients who are more than 50 years old and sustained low energy trauma whatever the sex is or any patient who has major risk factor (current or frequent recent use of oral or systemic glucocorticoids, untreated premature menopause or previous fragility fracture). We found that 96% of patients were 50 years old or more and 84% of the patients were females. 71% of patients were not referred to Osteoporosis clinic and 11% were already under the orthogeriatric care and 18% only were referred. Out of the 8 referred patients, 3 were referred on 1st appointment, 1 on the 3rd appointment, 1 on discharge from fracture clinic to GP again and 3 were without clear documentation of the time of referral. We concluded that we as trust are not compliant to the national guidelines with regards the osteoporosis review for the DRF as one of the first common presentations of fragility fractures. We also found that the reason for that is that there is no definitive clear pathway for the referral in our local guidelines. We recommended that the Osteoporosis clinic referral form needs to be available in the fracture clinic in an accessible place and needs to be filled by the doctor reviewing the patient in the fracture clinic in the 1st appointment. A liaison nurse also needs to ensure these forms have been filled and sent to the orthogeriatric team. Alternatively, we added a portal on our online database (e-trauma), therefore the patient who fulfils the criteria for bone health review should be referred to the orthogeriatric team to review.
Congenital talipes equinovarus (CTEV), also known as club foot or talipes is a common congenital disorder. Parents are using the Internet more and more as a source of information about health care. Unfortunately, the quality of health care information on the Internet varies. This study looked at information available to parents using two instruments for judging the equality of information on the internet. The top five search engines were searched on Google. Three of these were also included in the top 50 sites in Ireland so these 3 sites were used. The phrases CTEV and club foot were searched from all 3 platforms. Websites were then scrutinized using the HON code and the DISCERN tool. 54 organic sites were found for the 3 search engines using the key word club foot. For the key word CTEV 55 matches were returned for the three search engines. 4 websites displayed the HON code. Using the discern tool CTEV websites had a mean score of 60 with a standard deviation of 17. While club foot had a mean score of 56.8 with a standard deviation of 13. Max score 80. Large volumes of information are available to parents on the Internet. Often parents find comfort in sharing experiences and feel empowered by learning about their children's illnesses. However, information provided on the interned can also be ambiguous and disingenuous. Practitioners should be aware of a number of key websites that parents can be directed towards.
Innominate Osteotomy first described by Salter is one of the commonest procedures performed for treatment of Developmental Dysplasia of the Hip (DDH) in children. We recently described a less invasive technique for Innominate Osteotomy, which significantly reduces the operation time without compromising outcome (J Pediatr Orthop B. 2010 Jul;19(4):318–22). As part of the evolution of this procedure we now routinely use bioabsorbable pins (INION OTPS PIN, made from co-polymers of L-lactic acid, D-lactic acid and trimethylene carbonate) instead of K-wires to secure the graft. We prospectively followed-up 120 consecutive cases done using bioabsorbale pins over a 2 year period. The surgical technique was as described in our less invasive innominate osteotomy paper. Average age at surgery was 24 months (18–52) with mean follow-up period of 15 months (6–24 months). The mean preoperative acetabular index was 36.2o. Our results show a mean acetabular index of 18.7o (P< 0.0001) at latest follow-up with no loss of correction. We recorded three superficial wound infections (one MRSA), all resolved uneventfully. There was no foreign body reaction. The use of bioabsorbable pins eliminates the need for a second anaesthetic to remove the pins with significant cost benefit without compromising outcome.
Trauma is the leading cause of death and disability in children. Pelvic fractures although rare, with a reported incidence of one per 100,000 children per year are 2nd only to skull fractures with respect to morbidity. The objectives of this study were to improve understanding of paediatric pelvic fractures through a concise review of all aspects of these fractures and associated injuries. Understanding the patterns in which paediatric pelvic fractures and their associated injuries occur and the outcome of treatment is vital to the establishment of effective preventative, diagnostic and therapeutic interventions. All children admitted to our unit with a pelvic fracture over the 14-year period from January 1995 to December 2008 were identified. The complete medical records and radiographs of all patients were obtained and reviewed. Data recorded included, age, sex, mechanism of injury, Glasgow Coma Score, Injury Severity Score, fracture type, radiological investigation, length of in-patient stay, length of intensive care unit stay, blood transfusion requirement, associated injuries, management (both orthopaedic and non-orthopaedic), length of follow-up, and outcomeIntroduction
Patients and Methods
Athletes significantly alter their lumbar spinal motion when performing squat lifting at heavy weights. This altered motion effects a change in pressure in the posterior annulus of lumbar discs.
48 athletes performed 6 lifts at 40% maximum, 4 lifts at 60% maximum and 2 lifts at 80% maximum. Zebris 3-D motion analysis system used to measure lumbar spine motion. Exercise then repeated with weight lifting support belt. 4 cadaveric sheep spinal motion segments fixed to tension/compression loading frame, allowing compression replicating the forces seen in in vivo study. Pressure measurement achieved using a Flexiforce single element force sensor strip, positioned at posterior annulus. Posterior annulus pressure measured during axial compression and on compression with specimen fixed at 3° of extension.Hypothesis
Methods
Determine the minimum inhibitory concentration (MIC) of Povidone-iodine. Investigate the effect of Povidone-iodine on icaADBC operon encoded staphylococcal biofilm formation. Investigate wether any observed changes on biofilm by Povidone-iodine is mediated through a change in icaADBC operon.
A step-wise reduction of biofilm was observed at increasing sub-inhibitory doses of povidone-iodine (p<
0.0001). IcaA expression correlated with biofilm formation in staphylococcal organisms. Decrease in icaA expression was strongly associated with an increase in expression in the biofilm repressor gene, icaR. The repressive effect of povidone-iodine on biofilm formation by Staphylococcal bacteria is by a separate mechanism from its bacteriostatic mechanism of action.
Current intervention strategy is focussed on prevention of initial device colonisation and inhibition of genes encoding biofilm formation.
Determine the minimum inhibitory concentration (MIC) of betadine. Investigate the effect of betadine on icaADBC operon encoded staphylococcal biofilm formation. Investigate wether betadine can prevent bacterial adherence and biofilm formation by inhibition of the encoding genes.
Total RNA for cDNA synthesis was isolated from bacterial at different twofold dilutions of betadine concentrations. Real time polymerase chain reaction was used to quantify effects of betadine on gene expression pattern of the icaADBC operon using the constitutively expressed gyrB gene as internal control. Bacterial was cultivated on polystyrene plates coated with different sub-inhibitory and clinical in-use doses of betadine to assess surface adherence.
A step-wise reduction of biofilm was observed at increasing sub-inhibitory doses of betadine (p<
0.0001). IcaA expression correlated with biofilm formation in staphylococcal organisms. Decrease in icaA expression was strongly associated with an increase in expression in the biofilm repressor gene, icaR. The repressive effect of betadine on biofilm formation by Staphylococcal bacteria is by a separate mechanism from its bacteriostatic mechanism of action.
Prevention of bacterial surface attachment as demonstrated by this study is suggestive that these compounds could be developed as a surface coating agents for orthopaedic implants.
3-D motion analysis of lumbar spinal motion in athletes, during squat weight lifting. Pressure measurement of the posterior annulus following the motion analysis study.
4 cadaveric sheep spinal motion segments mounted in purpose built jig, replicating angulation seen in the in vivo motion study. These samples were then fixed to a tension/compression loading frame, replicating the forces seen in the in vivo study. Pressure measurement was achieved using a Flexiforce single element force sensor strip, positioned at the posterior annulus. Posterior annulus pressure was measured during axial compression and on compression with the specimen fixed at 3° of extension.
Significant decrease (p<
0.05) in flexion in all groups when lifting at 40% max was compared with lifting at 60% and 80% of max. Flexion from calibrated zero point ranged from 24.7° (40% group), to 6.8° (80% group). A progressively significant increase (p<
0.05) seen in extension in groups studied when lifting at 40% max was compared with lifting at 60% and 80% max lift. Extension from a calibrated zero point ranged from − 1.5° (40% group), to − 20.3° (80% group). No statistically significant difference found between motion seen when performing the exercise as a ‘free’ squat or when lifting using a support belt in any group studied. Initial uniform rise in measured pressure readings to a pressure of 350–400N, in the axially loaded and extension loaded specimens. Pressure experienced by the axially loaded group then gradually dropped below the pressure exerted by the loading frame, while the pressure experienced in the posterior annulus of the extension loaded specimens progressively increased. Comparing axially loaded specimens with specimens loaded in extension, there was an average increase in pressure of 36.4% in the posterior annulus, when the spine was loaded in 3° of extension at a pressure equivalent to the 80% lift in the in vivo motion study, in comparison to axial loading.
The cervical spine exhibits the greatest range of motion amongst the spinal segments due to its tri-planar components of movement. As a result, measurement of movements has proved difficult. A variety of methods have been used in an attempt to measure these movements but none have provided satisfactory triplanar data. This paper uses the Zebris ultrasonic 3-D motion analysis system to measure flexion, extension, range of lateral bending and range of axial rotation in five similar male and five similar female subjects with no history of neck injuries. The subjects were tested unrestrained and in soft and hard collars, as well as in Philadelphia, Miami J and Minerva orthoses. Results show that the Minerva is the most stable construct for restriction of movement in all planes in both groups (p<
0.001 vs. all groups (p=0.01 vs. Philadelphia in female extension), ANOVA). In the male group, the standard hard collar provides the second best resistance to flexion, lateral bending and axial rotation. The female group showed no one orthosis in second place overall. Looking at these results allows ranking of the measured orthoses in order of their three-dimensional stability. Furthermore, they validate the Zebris as a reliable and safe method of measurement of the complex movements of the cervical spine with low intersubject variability. In conclusion, this paper, for the first time presents reproducible data incorporating the composite triplanar movements of the cervical spine thus allowing comparative analysis of the three-dimensional construct stability of the studied orthoses. In addition, these results validate the use of the Zebris system for measurement of cervical spine motion.
The purpose of this study was to review the early results of a consecutive series of patients undergoing periac-etabular osteotomy (PAO) at Cappagh National Orthopaedic Hospital. The procedure was first carried out in 1998, and a total of 85 PAOs have been performed in 79 patients. The mean follow-up was 42 months (range 6-84 months). There were 72 females and 7 males with a mean age at the time of the operation of 22.9 years (range, 14-41 years). The preoperative diagnosis was developmental hip dysplasia in 80 hips, Legg-Calve-Perthes disease in one hip, congenital coxa vara in three hips, and slipped capital femoral epiphysis in one hip. The average Merle d’Aubigne score increased from 12.4 points preoperatively to 16 points at latest followup. The lateral center edge angle of Wiberg was between – 20 and +28 before surgery and was improved from 12 to 48 (average 30 degrees) following PAO. While, the anterior center edge angle of Lequesne and de Seze was between – 22 and +35 preoperatively and was improved by an average of 28 degrees (range, 17 – 40) postoperatively. The acetabular index angle decreased from an average of 24.8 preoperatively to 8.4 postoperatively. Clinical follow-up revealed that 77% of patients had no or mild pain, 33% of patients had a limp and 64% of patients were unlimited in physical activity, representing a markedly improved clinical outcome. Four patients underwent subsequent total hip arthroplasty. The short term results in this group of patients treated with PAO show reliable radiographic correction of deformity and improved clinical scores. The study reflects the learning curve associated with performing this procedure and the results that can be expected with a smaller clinical case-load than described in previous studies. We suggest that PAO may safely be carried out at a non-super-specialized institution provided the surgeons have sufficient experience and patients are selected appropriately.
Many pedicle screw instrumentation systems are currently available to the spine surgeon. Each system has its unique characteristics. It is important for the surgeon to understand the differences in these pedicle screw systems1 Following the introduction of a new spinal instrumentation set to our clinical practice we encountered two cases of pedicle screw breakage. We thus decided to investigate the mechanism of this screw failure (screw A) in these particular cases and to compare the biomechanical properties, through independent analysis, of a variety of pedicle screws from different manufacturers. Samples of the broken pedicle screws were retrieved at surgery. Surface analysis of the fracture area using the electron microscope, demonstrated features consistent with fatigue fracture. Pedicle screws of comparable size from a variety of manufacturers were gathered for independent analysis. Shadowgraph analysis was performed of each screw allowing multiple measurements to be taken of the screw’s geometry. Using this data stress concentration factors were determined demonstrating screw A to have larger values than all the other screws ranging from 2 – 3.6 times the nominal stress. The smaller teeth of screw A, spaced further apart than in the other screws, means that the large proportion of the load which would be carried by the threads is distributed over a smaller area resulting in higher stresses in the threads. The sharp corner at the root of the thread, acting as a stress concentrator, would become the focal point of these high stresses, and magnify them by 2 to 3.6 times. These increased stresses most likely account for an increased susceptibility to fatigue fracture seen in screw A. In conclusion it is important to be careful with the introduction and use of new pedicle screw materials and designs, that all the standard biomechanical testing has been performed to a satisfactory standard. Knowing the physical characteristics of the available pedicle screw instrumentation systems may allow the choice of pedicle screw best suited for a given clinical situation.
Slipped upper femoral epiphysis (SUFE) is a condition, which affects the immature hip joint. Many theories have been postulated as to its underlying aetiology however; its exact cause is, as yet unknown. The final common pathway appears to be failure of the of the growth plate to resist shearing forces, giving rise to displacement of the femoral head. We hypothesized that the lubricating ability of the synovial fluid in hip joints of children with SUFE was defective, thereby allowing increasing shear forces on the physis to occur, so that when the joint is loaded it will fail at its weakest point, namely the capital epiphysis.
Nine patients had additional acetabular bone grafting with autologous femoral head, two patients had subtrochanteric osteotomy, and another patient had an adductor tenotomy performed at the time of their surgery. Follow-up ranged from 6 to 44 (mean 19.6) months.
The mean age of diagnosis was 14.6 months (range 4–72). Many of the late referrals had risk factors for DDH.