Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 34 - 38
1 Jan 2007
Epinette J Manley MT

This study describes 146 primary total knee replacements, either fully or partially coated with hydroxyapatite of which 74 knees in 68 patients were available for clinical and radiological assessment at a mean of 11.2 years (10 to 15). The global failure rate was 1.37% and survival rate with mechanical failure as the end-point was 98.14%. Radiological assessment indicated intimate contact between bone and the hydroxyapatite coating. Over time the hydroxyapatite coating appears to encourage filling of interface gaps remaining after surgery. Our results compare favourably with those of series describing cemented or porous-coated knee replacements, and suggest that fixation with hydroxyapatite is a reliable option in primary total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 361 - 361
1 Mar 2004
Capello WN DñAntonio JA Bonutti P Manley MT
Full Access

Aims: To compare acetabular surface treatments in alumina on alumina clinical trial. Methods: Utilizing new improved alumina ceramic materials and implant design, 514 hips were implanted in a US IDE prospective randomized study. All patients received the same press-þt hydroxylapatite-coated (HA) femoral stem. Two-thirds (349 hips) received an alumina ceramic bearing surface, while one-third (165 hips) received a cobalt chrome on polyethylene bearing. The alumina group was further divided with approximately one-half receiving a porous-coated titanium shell and alumina insert (172 hips Ð System I), and one-half receiving an arc deposited titanium shell with HA coating and alumina insert (177 hips Ð System II). System III, the control group, had a porous-coated titanium shell and polyethylene insert. All acetabular shells were of identical external geometry. Results: At latest follow-up, minimum 2 years (2–4 year range), differences were noted in the pattern of development of radiolucent lines around the acetabular components. Radiolucent lines were noted most commonly in De Lee Charnley Zone 3 in porous-coated shells (25/164 hips Ð System I, 33/151 hips Ð System III respectively). Radiolucent lines in Zone 3 were absent in the arc deposited with HA shells (System II) (p=0.001). Conclusions: These results appear to demonstrate that PSL style cups with arc dep and HA coating may improve levels of primary þxation versus that of porous-coated acetabular components.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 361 - 361
1 Mar 2004
DñAntonio JA Capello WN Manley MT Bierbaum B
Full Access

Aims: Todayñs major challenge for total hip arthroplasty is to minimize wear and osteolysis in our younger and more active patients. Alumina ceramic bearings have known superior wear resistance and lubrication and do not carry a risk of ion release. One objective of this clinical study was to evaluate the use of alumina-on-alumina ceramics with proven implants that have had successful track records with regard to þxation (on a prospective randomized basis)Methods: Utilizing new improved alumina ceramic materials and implant design 514 hips were implanted in a multicenter US IDE prospective and randomized study. The study compared alumina-on-alumina ceramic bearings to a cobalt chrome-on-polyethylene bearing. All patients received the same press-þt hydroxylapatite-coated femoral stem while two-thirds (349 hips) received alumina ceramic bearings and one-third (165 hips) received the cobalt chrome-on-polyethylene bearing. Results: With a mean follow-up of greater than 40 months (36–60 months) there is no signiþcant difference in clinical performance between the two patient cohorts. Radiographically proximal femoral osteolysis has been noted in the control patients but in no patients that received the ceramic bearing. With Continued Access, a total of 947 alumina ceramic bearings have been implanted to date. There have been no ceramic fractures or alumina bearing failures. Conclusions: This new alumina-alumina ceramic bearing provides for a safe option for the younger and more active patient population.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 869 - 875
1 Sep 1998
Edidin AA Merritt PO Hack BH Manley MT

We describe the development and early clinical application of a ported, proximally-cemented titanium stem for cemented total hip arthroplasty. PMMA bone cement is delivered to the proximal femur under pressure after the stem has been positioned within the femoral canal. A mid-stem cement occluder contains the cement to the proximal stem only. A tapered body is incorporated in the design of the stem to reduce the structural stiffness and hence the degree of stress shielding within the reconstructed joint.

We performed preclinical studies to measure the reduction in porosity and the pressurisation achieved. The porosity, as measured by the void percentage within the cured cement mantle, was reduced by more than 50% and there was an almost threefold increase in the mean pressure. Mechanical testing of the stem, using a three-point bend test, showed that the addition of cement injection ports on the anterior and posterior sides of the body of the proximal stem did not reduce its strength. Finite-element analysis indicated that, compared with a fully-cemented conventional stem, there was no change in the stresses within the cement mantle. In a series of 40 proximally-cemented stems followed for up to six years (mean 51 months) the mean Harris hip score was 91, and 85% of patients had good or excellent results. There was excellent pain relief, an increased level of activity and good patient satisfaction. One mechanical failure of the stem required revision at three years after implantation.

The early results indicate that the clinical performance was equal to that achieved with other modern cemented stems. Radiological evaluation showed excellent results with no evidence of stress shielding. Further follow-up will determine if long-term stress shielding is reduced and if revision is made easier by the absence of a distal cement mantle.