Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 13 - 13
1 May 2014
Arthur C Phillips J Toms A Mandalia V
Full Access

Kinematic alignment has increased in popularity over the last few years in an attempt to improve clinical outcomes following total knee arthroplasty (TKA).

In our unit kinematic alignment has been used with patient-specific cutting guides as part of on-going clinical trials. We performed a retrospective analysis on all the TKA which had been planned to be implanted outside of the mechanical axis (0° ± 3°) based on pre-operative MRI scans and looked at their radiographic and clinical outcomes.

We identified 21 knees which had been implanted as ‘planned outliers’. All had clinical and radiographic follow up to a mean 11.6 months post op. All had a standard long leg alignment radiograph performed at 6 weeks post op to confirm alignment.

All patients had a good improvement in their Oxford Knee Scores with mean improvement from 23 pre-op to 42 at 1 year. Of our patients none had a poor clinical outcome due to the alignment of their TKA, 1 patient had a poor outcome because of a quadriceps rupture which occurred 4 months post-op. There were no post-operative radiographic abnormalities.

In our unit kinematic alignment outside of the mechanical axis is not associated with an increased rate of short term complications.