Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔPs, based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived: ΔPs=sin-1(sin α sin θ) The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use.
High tibial osteotomy (HTO) is an effective surgical treatment for isolated medial compartment knee osteoarthritis; however, widespread adoption is limited due to difficulty in achieving the planned correction, and patient dissatisfaction due to soft tissue irritation. A new HTO system – Tailored Osteotomy Knee Alignment (TOKA®, 3D Metal Printing Ltd, Bath, UK) could potentially address these barriers having a custom titanium plate and titanium surgical guides featuring a unique mechanism for precise osteotomy opening as well as saw cutting and drilling guides. The aim of this study was to assess the accuracy of this novel HTO system using cadaveric specimens; a preclinical testing stage ahead of first-in-human surgery according to the ‘IDEAL-D’ framework for device innovation. Local ethics committee approval was obtained. The novel opening wedge HTO procedure was performed on eight cadaver leg specimens. Whole lower limb CT scans pre- and post-operatively provided geometrical assessment quantifying the discrepancy between pre-planned and post-operative measurements for key variables: the gap opening angle and the patient specific surgical instrumentation positioning and rotation - assessed using the implanted plate. The average discrepancy between the pre-operative plan and the post-operative osteotomy correction angle was: 0.0 ± 0.2°. The R2 value for the regression correlation was 0.95. The average error in implant positioning was −0.4 ± 4.3 mm, −2.6 ± 3.4 mm and 3.1 ± 1.7° vertically, horizontally, and rotationally respectively. This novel HTO surgery has greater accuracy and smaller variability in correction angle achieved compared to that reported for conventional or other patient specific methods with published data available. This system could potentially improve the accuracy and reliability of osteotomy correction angles achieved surgically.
Whilst the literature abounds with patient reported outcomes following total knee replacement (TKR) there is a paucity of literature covering objective functional outcomes. Awareness of objective functional outcomes following TKR is key to the consent process and relating it to pre-operative function enables a tailored approach to consent. Identify trends in a range of functional outcomes prior to and following TKR up to one year post-operatively.Abstract
Background
Objectives