Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 34 - 34
1 Nov 2022
Haleem S Malik M Azzopardi C Botchu R Marks D
Full Access

Abstract

Purpose

Intracanal rib head penetration is a well-known entity in dystrophic scoliotic curves in neurofibromatosis type 1. There is potential for spinal cord injury if this is not recognised and managed appropriately. No current CT-based classification system is currently in use to quantify rib head penetration. This study aims to propose and evaluate a novel CT-based classification for rib head penetration primarily for neurofibromatosis but which can also be utilised in other conditions of rib head penetration.

Materials and methods

The grading was developed as four grades: normal rib head (RH) position—Grade 0, subluxed ext-racanal RH position—Grade 1, RH at pedicle—Grade 2, intracanal RH—Grade 3. Grade 3 was further classified depending on the head position in the canal divided into thirds. Rib head penetration into proximal third (from ipsilateral side)—Grade 3A, into the middle third—Grade 3B and into the distal third—Grade 3C. Seventy-five axial CT images of Neurofibromatosis Type 1 patients in the paediatric age group were reviewed by a radiologist and a spinal surgeon independently to assess interobserver and intraobserver agreement of the novel CT classification. Agreement analysis was performed using the weighted Kappa statistic.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 31 - 31
1 Jan 2022
Haleem S Malik M Guduri V Azzopardi C James S Botchu R
Full Access

Abstract

Purpose

No clinical CT based classification system is currently in use for Lumbar Foraminal Stenosis. MRI scanners are not easily available, are expensive and may be contraindicated in an increasing number of patients. This study aims to propose and evaluate the reproducibility of a novel CT based classification for lumbar foraminal stenosis.

Materials and Methods

The grading was developed as 4 grades. Normal foramen – Grade 0, Anteroposterior(AP)/Superoinferior (SI)(single plane) fat compression – Grade 1, Both AP/SI compression (two planes) – Grade 2 (both AP and SI) without distortion of nerve root, Grade 2 with distortion of nerve root – Grade 3.

800 lumbar foramen of a cohort of 100 random patients over the age of 60 who had undergone both CT and MRI scans were reviewed by two radiologists independently to assess agreement of the novel CT classification against the MRI based grading system of Lee et al. Interobserver(n=400) and intraobserver agreement(n=160) was also evaluated. Agreement analysis was performed using the Weighted Kappa statistic.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 64 - 64
1 Feb 2012
Malik M Gray J Kay P
Full Access

We describe the association between post-operative femoral stem radiological appearances and aseptic failure of THA (total hip arthroplasty) following a retrospective review of records and radiographs of all patients attending for follow-up between August 2002 and August 2003 who had a cemented Charnley femoral stem and either a cemented polyethylene acetabular cup inserted. Femoral stem aseptic loosening was defined either by findings at revision surgery, the definite radiographic loosening criteria of Harris or progressive endosteal cavitation across zones as described by Gruen. Well-fixed control THAs were defined as those that demonstrated none of the radiographic features of aseptic loosening or ‘at risk’ signs as described by Wroblewski. Parameters measured were: Alignment, Barrack grade of cementation, cement mantle width of the cement mantle and the presence and width of any radiolucent lines.

Sixty-three hips were entered into the aseptic failure group and 138 into the control group. The alignment of the femoral stem was not associated with failure (p=0.283). Thickness of the cement mantle was statistically associated with failure in Gruen zones 6 (p=0.040) and Gruen zone 7 (p=0.003). A significant association for the presence of radiolucent lines was found for Gruen zones 3 (p=0.0001) and 5 (p=0.0001). The grade of cementation as measured by the Barrack grade was strongly associated with failure for grades C (p=0.001) and D (p=0.001).

This study has demonstrated that easily applied radiological criteria can be used to identify ‘at risk’ Charnley THAs from the immediate post-operative AP radiograph.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 7 - 7
1 Feb 2012
Malik M Bayat A Jury F Oliver W Kay P
Full Access

The Osteoprotegerin/RANK/RANKL system has been implicated in the biological cascade of events initiated by particulate wear debris and bacterial infection resulting in periprosthetic bone loss around loosened total hip arthroplasties (THA). Individual responses to such stimuli may be dictated by genetic variation and we have studied the effect of single nucleotide polymorphisms (SNPs) within these genes.

We performed a case control study of the Osteoprotegerin, RANK and RANKL genes for possible association with deep sepsis or aseptic loosening. All patients included in the study were Caucasian and had had a cemented Charnley THA and polyethylene acetabular cup. Cases consisted of 91 patients with early aseptic loosening and 71 patients with microbiological evidence at surgery of deep infection. Controls consisted of 150 THAs that were clinically asymptomatic for over 10 years and demonstrated no radiographic features of aseptic loosening. DNA samples from all individuals were genotyped using Taqman allelic discrimination.

The A allele (p<0.001) and homozygous genotype A/A (p<0.001) for the OPG-163 SNP were highly associated with aseptic failure. Additionally, the RANK-575 (C/T SNP) T allele (p=0.004) and T/T genotype (p=0.008) frequencies were associated with aseptic failure. No statistically significant relationship was found between aseptic loosening and the OPG- 245 or OPG-1181 SNPs.

When the septic group was compared to controls, the frequency of the A allele (p<0.001) and homozygous genotype A/A (p<0.001) for the OPG-163 SNP were statistically significant. No statistically significant relationship was found between septic failure and the OPG- 245, OPG-1181 or RANK-575 SNPs.

Aseptic loosening and possibly deep infection of THA may be under genetic influence to candidate susceptibility genes. SNP markers may serve as predictors of implant survival and aid pharmacogenomic prevention of THA failure.