Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 42 - 42
1 Aug 2018
Malchau E Rolfson O Grant P Thanner J Karlsson M Mohaddes M
Full Access

Arthroplasty registries have played a key role in the treatment of patients with various joint diseases and conditions since their conception. Swedish hip and knee arthroplasty registries were initiated in late 1970's. The main aim of registries was to create feedback to surgeons. During the last two decades with introduction of patient reported outcomes, data from registries have been increasingly used to compare caregivers and to improve quality of health care. According to the Swedish Hip Arthroplasty Register (SHAR) Sahlgrenska University Hospital had been underperforming during years 2006–2012. In order to improve the outcomes a systematic data driven approach using local and national registries, based on value based management was undertaken.

Representatives from all categories of healthcare staff and patients were invited to join a newly initiated group. The group was asked to define which measurement that contributed most to improve healthcare. Data from SHAR and local registries were used and seventeen different areas of improvement were identified. Several workgroups were initiated.

Between years 2013 and 2017 there was an increase of 60% in the annual volume of elective THAs. The length of stay decreased from 6.4 days to 1.8 days. Satisfaction with outcome of surgery increased from 76% to 90%. Adverse events decreased from 28% to 10%. The risk of re-operations within 2 years decreased from 2.4% to 1.9%.

Data from a national and a local registry were used to identify and implement changes in a large university hospital. Engaging member of staff and creating a graphical tool for continuous feedback drastically improved the quality of care whilst increasing the availability of hip replacements and reducing costs. This project demonstrates the power of registry data and a patient centered approach in engaging staff and improving healthcare.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 37 - 37
1 Jun 2017
Malchau E Rolfson O Welander A Grant P Karlsson M Mohaddes M
Full Access

During the last decade primary total hip arthroplasty surgery (THA) has increased with 30% in Sweden. Current law guarantees the patient a right to treatment within 90 days. The public health system has had difficulties meeting the increasing demand. Therefore, in 2012 a systematic review of the patients planned for THA was initiated at Sahlgrenska University Hospital's joint replacement unit. In late 2013 the value-based health care (VBHC) management was introduced in our unit.

In 2012 a systematic approach based on the Fast-Track concept was implemented in the joint replacement unit. In 2013 a workgroup consisting of health care professionals involved in the treatment of THA patients was created to improve chosen outcome parameters.

During 2011–2016 the number of elective THA has increased from 317 to 486. The cost per patient has decreased from 75,000 SEK to 65,000 SEK. Length of stay has decreased from 5.9 days to 2.5 days. Satisfaction with outcome of surgery one year after THA increased from 76% to 88%. The number of adverse events decreased from 29% to 11%. Number of re-operations within 2 years decreased from 2,7% to 1,9%.

Fast-Track and VBHC management was initially received with modest enthusiasm in our unit, and was regarded as means to increase production whilst possibly endanger the well-being of the patients. By using continuous feedback using the data collected it was possible to effectively communicate to patients and caregivers that the patients benefitted from the implementation.

VBHC primary aim is to improve patient outcomes and synergetically improve cost and process measurements. This should be appealing to both caregivers and administrators.

Focusing on improvement of outcomes after THA combined with VBHC management has contributed to improvement in quality of care and availability of treatment whilst decreasing cost per patient.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 61 - 61
1 Jan 2016
Muratoglu O Bichara D Malchau E Hylleholt N Cakmak S
Full Access

Introduction

UHMWPE particle-induced osteolysis is one of the major causes of arthroplasty revisions. Recent in vitro findings have suggested that UHMWPE wear particles containing vitamin-E (VE) may have reduced functional biologic activity and decreased potential to cause osteolysis (Bladed C. L. et al, JBMR B 2012 and 2013). This is of significant importance since VE-stabilized cross-linked UHMWPEs were recently introduced for clinical use, and there is no in vivo data determining the effects of wear debris. In this study we hypothesized that particles from VE-stabilized, radiation cross-linked UHMWPE (VE-UHMWPE) would cause reduced levels of osteolysis in a murine calvarial bone model when compared to virgin gamma irradiated cross-linked UHMWPE.

Methodology

Study groups were the following: 1). Radiation cross-linked VE-UHMWPE (0.8% by weight) diffused after 100 kGy; 2). Radiation cross-linked virgin UHMWPE (virgin UHMWPE); 3). Sham controls. Particle generation and implantation: UHMWPE was sent to Bioengineering Solutions (Oak Park, IL) for particle generation. After IACUC approval, C57BL/6 mice (n=12 for each group) received equal amount of particulate debris (3mg) overlying the calvarium and were euthanized after 10 days. Micro-CT scans: High resolution micro-CT scans were performed using a set voltage of 70 kV and current of 70 µA. Topographical Grading Scale: Each calvarial bone was blindly scored using the following scale: 0=No osteolysis, defined as intact bone; 1=Minimal osteolysis, affecting 1/3 or less of the bone area; 2=Moderate osteolysis, affecting at least 2/3 of the bone area; 3=Severe osteolysis, defined as completely osteolytic bone. Histology: H&E and TRAP staining was done on tissue to confirm micro-CT findings and quantify osteoclasts. Statistical Analysis: Inter-rater analysis was done using Cohen's kappa analysis. An inter-rater coefficient >0.65 was considered as high inter-rater agreement. Comparison between groups was made using one-way ANOVA with post hoc Bonferroni correction for multiple comparisons. Correlations are reported as Spearman's rho. P-value<0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 255 - 255
1 Jul 2014
Bichara D Malchau E Sillesen N Cakmak S Muratoglu O
Full Access

Summary Statement

Vitamin E-UHMWPE particles have a reduced osteolysis potential in vivo when compared to virgin, highly cross-linked UHMWPE in a murine calvarial bone model.

Introduction

Ultra high-molecular weight polyethylene (UHMWPE) particle-induced osteolysis is one of the major causes of arthroplasty revisions. The lack of particle clearance from the joint inevitably leads to the upregulation of the inflammatory cascade, resulting in bone resorption and implant loosening. Recent in vitro findings (Bladed CL et al. ORS 2011 and J Biomed Mater Res B Appl Biomater, 2012) have suggested that UHMWPE wear particles containing vitamin-E (VE) may have reduced functional biologic activity and decreased potential to cause osteolysis. This is of significant importance since VE-stabilised cross-linked UHMWPEs were recently introduced for clinical use, and there is no in vivo data determining the effects of wear debris from this new generation of implants. In this study we hypothesised that particles from VE-stabilised, radiation cross-linked UHMWPE (VE-UHMWPE) would cause reduced levels of osteolysis in a murine calvarial bone model when compared to virgin gamma irradiated cross-linked UHMWPE.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 145 - 145
1 Dec 2013
Muratoglu O Bichara D Malchau E Hylleholt N Oral SCE
Full Access

Introduction

In vitro findings (Bladed CL et al. ORS 2011 and J Biomed Mater Res B Appl Biomater, 2012) have suggested that UHMWPE wear particles containing vitamin-E (VE) may have reduced functional biologic activity and decreased osteolytic potential. Currently, there is no in vivo data determining the effects of wear debris from this new generation of implants. In this study we hypothesized that particles from VE-stabilized, radiation cross-linked UHMWPE (VE-UHMWPE) would cause reduced levels of osteolysis in a murine calvarial bone model when compared to virgin gamma irradiated cross-linked UHMWPE.

Methods

Study groups: 1). Radiation cross-linked VE-UHMWPE, 0.8% by weight, diffused after 100 kGy; 2). Radiation cross-linked virgin UHMWPE (virgin UHMWPE); 3). Shams. Particle generation and implantation: UHMWPE was sent to Bioengineering Solutions for particle generation. After IACUC approval, C57BL/6 mice (n = 12 for each group) received 3 mg of particulate debris overlying the calvarium and euthanized after 10 days. Micro-CT scans: Performed using an X-Tek-HMX-ST-225 with 70 kV voltage and 70 μA current. Topographical Grading Scale: Each calvarial bone was blindly scored with the following scale: 0 = No osteolysis, defined as intact bone; 1 = Minimal osteolysis, affecting 1/3 or less of the bone area; 2 = Moderate osteolysis, affecting at least 2/3 of the bone area; 3 = Severe osteolysis, defined as completely osteolytic bone. Histology H&E and TRAP staining was performed. Statistical Analysis: Inter-rater analysis was performed using Cohen's kappa analysis. Inter-rater coefficient >0.65 was considered as high inter-rater agreement. Comparison between groups was made using one-way ANOVA with post hoc Bonferroni correction for multiple comparisons. Correlations are reported as Spearman's rho. A p-value<0.05 was considered statistically significant.