Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 103 - 103
1 Jan 2016
Kim Y Tanaka C Maki A Tada H Kanoe H Shirai T
Full Access

Periprosthetic femoral fractures are becoming increasingly common and are a major complication of total hip arthroplasty (THA) and bipolar hemiarthroplasty (BHA). We report a retrospective review of the outcomes of treatment of 11 periprosthetic fractures after femoral revision using a long stem. Eleven female patients with a mean age of 79.2 years (70 to 91 years) were treated for a Vancouver type B1 fracture between 1998 and 2013. The status of the initial arthroplasty was THA in 5 patients and BHA in 6 patients. The original diagnosis was femoral neck fracture in 5 patients, osteoarthritis in 5 patients, and avascular necrosis of femoral head in 1 patient. Seven patients had had a cemented femoral component and 4 had had a cementless femoral component. The mean numbers of previous surgeries were 3.2 times (2 to 5 times). A previous history of fracture in the same femur was found in 7 hips including 5 femoral neck fractures, 3 periprosthetic fractures. The cause of the latest revision surgery was aseptic loosening in 6 hips, periprosthetic fracture in 3 hips, and infection in 2 hips. The average time to fracture after femoral revision using a long stem was 106.5 months (12 to 240 months). The average follow-up was 58.9 months (8 to 180 months). The fracture pattern was a transverse fracture in 6 hips and an oblique fracture in 5 hips. The type B1 fractures were treated with open reduction and internal fixation in 9 hips, 6 of which were reinforced with bone grafts. Seven patients were treated with a locking compression plate and cerclage wiring, and 2 patients were treated with a Dall-Miles system. Two other periprosthetic fractures were treated with femoral revision. One was revised because of stem breakage, and the other was a transverse fracture associated with very poor bone quality, which received a femoral revision with a long stem and a locking compression plate. All fractures except one achieved primary union. This failed case had a bone defect at the fracture site, and revision surgery using a cementless long stem and allografts was successful. These finding suggest that a type B1 fracture after revision using a long stem associated with very poor bone quality or bone loss might be considered as a type B3 fracture, and femoral revision might be the treatment of choice.