Syed F Magra M Saunders P Ugwuoke A Young S
Full Access

Introduction

Primary fixation in uncemented Total Hip Replacement (THR) is achieved by implanting an appropriately sized stem. Last year, in our pilot study, we classified undersizing & reported the incidence of subsidence & radiolucent lines (RLL) in undersized uncemented stems. Now we report on a larger cohort of patients, reporting undersizing and its association with radiolucent lines and subsidence. Secondarily we report on the effect of using a collar, patients' BMI, and in a smaller group the five-year failure rate.

Methods

A retrospective review of electronic records of 1337 cases who underwent THR using the Corail stem was carried out. 1204 (Collared 1042, Uncollared 162) had a minimum follow up of 1 year, 693 of those had a follow up of at least 5 years. Radiological review was carried out by 2 independent investigators.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1010 - 1017
1 Aug 2018
Jain S Magra M Dube B Veysi VT Whitwell GS Aderinto JB Emerton ME Stone MH Pandit HG

Aims

This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up.

Patients and Methods

A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 36 - 36
1 May 2018
Jain S Magra M Dube B Veysi V Whitwell G Aderinto J Emerton M Stone M Pandit H
Full Access

Introduction

Reverse hybrid total hip replacement (THR) offers significant theoretical benefits but is uncommonly used. Our primary objective was to evaluate implant survival with all cause revision and revision for aseptic loosening of either component as endpoints.

Patients/Materials & Methods

Data was collected prospectively on 1, 088 (988 patients) consecutive reverse hybrid THRs. Mean patient age was 69.3 years (range, 21–94) and mean follow-up was 8.2 years (range, 5–11.3). No patients were lost to follow-up. Overall, 194 (17.8%) procedures were performed in patients under 60 years, 666 (61.1%) were performed in female patients and 349 (32.1%) were performed by a trainee. Acetabular components were ultra-high molecular weight polyethylene in 415 (38.1%) hips, highly cross-linked polyethylene in 669 (61.5%) hips and vitamin E stabilised polyethylene in 4 (0.4%) hips. Femoral stems were collared in 757 (69.7%) hips and collarless in 331 (30.3%) hips. Femoral head sizes were 28 mm in 957 (87.9%) hips and 32 mm in 131 (12.1%) hips. Survival analysis was performed using Kaplan Meier methodology. Log rank tests were used to asses differences in survival by age, gender, head size and surgeon grade.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 38 - 38
1 May 2018
Magra M McConnell J Syed F Saunders P Young S
Full Access

Introduction

Undersizing of an uncemented femoral stem is a post-operative description of a radiograph with unclear clinical importance. It may not always translate into a suboptimal clinical outcome.

Aim

To describe a novel classification system of undersizing in a fully hydroxyapatite coated femoral implant, assess if it could be reliably reported between observers, and describe a simple way to assess the degree of undersizing on an AP radiograph.