Healthcare associated infections (HAI) pose a major threat to patients admitted to hospitals, and infection rates following orthopaedic arthroplasty surgery are as high as 4%, while the infection rates are even higher after revision surgery. 405 nm High-Intensity Narrow Spectrum (HINS) light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in orthopaedic surgery. Cultured rat osteoblasts were exposed to 405 nm light to investigate if bactericidal doses of light could be used safely in the presence of mammalian cells. Cell viability was measured by MTT reduction and microscopy techniques, function by alkaline phosphatase activity, and proliferation by the BrdU assay. Exposures of up to a dose of 36 J/cm2 had no significant effect on osteoblast cell viability, whilst exposure of a variety of clinically relevant bacteria, to 36 J/cm2 resulted in up to 100% kill. Exposure to a higher dose of 54 J/cm2 significantly affected the osteoblast cell viability, indicating dose dependency. Work also demonstrated that 405 nm light exposure induces reactive oxygen species (ROS) production in both mammalian and bacterial cells, as shown by fluorescence generated from 6-carboxy-2′,7′-dichlorodihydrofluorescein diacetate dye. The mammalian cells were significantly protected from dying at 54 J/cm2 by catalase, which detoxifies H2O2. Bacterial cells were significantly protected by sodium pyruvate (H2O2 scavenger) and by a combination of free radical scavengers (sodium pyruvate, dimethyl thiourea (·OH scavenger), catalase) at 162 and 324 J/cm2. Thus the cytotoxic mechanism of 405 nm light in mammalian cells and bacteria is likely oxidative stress involving predominantly H2O2 generation, with other ROS contributing to the damage. Additional work describing the potential for incorporation of this antimicrobial light within operating theatre lighting systems will also be discussed, and this, coupled with the cell viability and cytotoxicity results, suggests that 405 nm light could have great potential for continual patient safe decontamination during orthopaedic replacement surgeries and thereby reduce the incidence of infections.
High-intensity narrow-spectrum (HINS) light is
a novel violet-blue light inactivation technology which kills bacteria through
a photodynamic process, and has been shown to have bactericidal
activity against a wide range of species. Specimens from patients
with infected hip and knee arthroplasties were collected over a
one-year period (1 May 2009 to 30 April 2010). A range of these
microbial isolates were tested for sensitivity to HINS-light. During
testing, suspensions of the pathogens were exposed to increasing
doses of HINS-light (of 123mW/cm2 irradiance). Non-light exposed
control samples were also used. The samples were then plated onto
agar plates and incubated at 37°C for 24 hours before enumeration.
Complete inactivation (greater than 4-log10 reduction)
was achieved for all of the isolates. The typical inactivation curve
showed a slow initial reaction followed by a rapid period of inactivation.
The doses of HINS-light required ranged between 118 and 2214 J/cm2.
Gram-positive bacteria were generally found to be more susceptible
than Gram-negative. As HINS-light uses visible wavelengths, it can be safely used
in the presence of patients and staff. This unique feature could
lead to its possible use in the prevention of infection during surgery
and post-operative dressing changes. Cite this article: