header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 16 - 16
1 Nov 2015
Masud S Al-Azzani W Thomas R Carpenter E White S Lyons K
Full Access

Introduction

Occult hip fractures occur in 3% of cases. Delay in treatment results in significantly increased morbidity and mortality. NICE guidelines recommend cross-sectional imaging within 24 hours and surgery on the day of, or day after, admission. MRI was the standard imaging modality for suspected occult hip fractures in our institution, but since January 2013, we have switched to multi-detector CT (MDCT) scan.

Our aims were to investigate whether MDCT has improved the times to diagnosis and surgery; and whether it resulted in missed hip fractures.

Patients/Materials & Methods

Retrospective review of a consecutive series of patients between 01/01/2013 and 31/08/2014 who had MDCT scan for suspected occult hip fracture. Missed fracture was defined as a patient re-presenting with hip fracture within six weeks of a negative scan. A comparative group of consecutive MRI scans from 01/01/2011 to 31/12/2012 was used.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1045 - 1050
1 Aug 2012
Malek IA King A Sharma H Malek S Lyons K Jones S John A

Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 µg/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 µg/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%).

Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.