Diabetic foot disease is a major public health problem with an annual NHS expenditure in excess of £1 billion. Infection increases risk of major amputation fivefold. Due to the polymicrobial nature of diabetic foot infections, it is often difficult to isolate the correct organism with conventional culture techniques, to deliver appropriate narrow spectrum antibiotics. Rapid DNA-based technology using multi-channel arrays presents a quicker alternative and has previously been used effectively in intensive care and respiratory medicine. We gained institutional and Local Ethics Committee approval for a prospective cohort study of patients with clinically infected diabetic foot wounds. They all had deep tissue samples taken in clinic processed with conventional culture and real-time PCR TaqMan array.Introduction
Methods
The effect of BMI on patient-reported outcomes following total ankle replacement (TAR) is uncertain and the change in BMI experienced by these patients in the 5 years following surgery has not been studied. We report a series of 106 patients with complete 5-year data on BMI and patient-reported outcome scores. Patients undergoing TAR between 2006 and 2009, took part in the hospital joint registry, which provides routine clinical audit of patient progress following total joint arthroplasty; therefore, ethics committee approval was not required for this study. Data on BMI, Foot and Ankle Score (FAOS) and SF-36 score were collected preoperatively and annually postoperatively. Patients who were obese (BMI >30) had lower FAOS scores pre-operatively and at 5 years, however this did not reach significance. Both obese (p = 0.0004) and non-obese (p < 0.0001) patients demonstrated a significant improvement in FAOS score from baseline to 5 years. This improvement was more marked for the non-obese patients. No significant differences were seen for SF36 scores between obese and non-obese patients either at baseline or 5 years. There was a trend for improved score in both groups. Mean pre-operative BMI was 28.49. Mean post-operative BMI was 28.33. The mean difference between pre- and post-operative BMI was −0.15, which was not statistically significant (p=0.55). There were no significant differences in revisions in the obese (2) and non-obese (1 and one awaited) groups at 5 years. This data supports use of TAR in the obese population, as significant increases in mean FAOS score were seen in this group at 5 years. Obesity did not have a significant influence on patients' overall health perceptions, measured by the SF36 and a trend for improvement was seen in both obese and non-obese patients. TAR cannot be relied upon to result in significant post-operative weight-loss without further interventions.
Platelet rich plasma has been advocated for the treatment of plantar fasciitis but there are few good quality clinical trials to support its use. We report a pilot double blind randomised controlled trial of platelet rich plasma versus normal saline. Patients with more than 6 months of MRI proven plantar fasciitis who had failed conservative management were invited to participate in this study. Patients were block randomised to either platelet rich plasma injection (intervention) or equivalent volume of normal saline (control). The techniques used for the injection and rehabilitation were standardised for both groups. The patient and independent assessor were blinded. Visual analogue scale for pain (VAS) and painDETECT were recorded pre-op and at 6 months. Twenty-eight patients (19 females, mean age 50 years) were recruited, with 14 randomised to each arm. At 6 month follow-up, 8 patients (28.6%) were lost to follow-up. There was a significant change in VAS score from baseline to follow-up in both intervention (mean change 37.2, p = 0.008) and control (mean change 42.2, p = 0.003) groups. However there was no difference between the arms in terms of the change in VAS score from baseline to follow-up (p = 0.183). There was no correlation between pre-op PainDETECT score and change in VAS.Methods
Results
Subacromial corticosteroid injections are a well-recognised management for chronic shoulder pain and are routinely used in general practice and musculoskeletal clinics. A seventy-four year old lady presented with a one-year history of a painful shoulder, which clinically manifested as a rotator cuff tear with impingement syndrome. Following three subacromial depo-medrone injections, the patient developed a painless “cold” lump which was investigated as a suspicious, possibly metastatic lesion. This lump slowly developed a sinus and a subsequent MRI scan identified a large intra-articular abscess formation. The sinus then progressed to a large intra-articular 5×8 cm cavity with exposed bone (picture available). The patient had no diagnosis of TB but had pathogen exposure as a child via her parents. The patient underwent three weeks of multiple débridement and intravenous amoxicillin/flucloxacillin to treat This unique case study highlights that intra-articular corticosteroid can precipitate the first presentation of Taking a TB exposure history is indicated prior to local immunosuppressant injection, particularly in the older age group of western populations and ethnicities with known risk factors.
Degree of early integration of titanium alloy implants into bone is an important predictor of long term implant success in arthroplasty. The correlation between observations on early cell adhesion and the ability of modified surfaces to affect osseointegration of implants in in vivo models is unclear. We hypothesised that observation of increased focal adhesion complexes in early cultures of osteoblasts would correlate with increased osseointegration of treated implants in an animal model. Longer term culture of rat osteoblasts for alkaline phosphatase activity indicated that cells cultured on the 9V treated surfaces were displaying greater alkaline phosphatase activity at 14 days. Bone nodule formation at 28 days demonstrated a trend towards smaller area of bone nodules on the surfaces treated at 9V then those treated at 3V and 5V. A rat model was employed for testing mechanical push-out strength of experimental implants and demonstrated a trend towards increased yield strength of the bone-implant interface for implants treated at 3V180s and 5V180s. Histomorphometry was performed and no statistically significant differences in percentage area of contact with mineralised bone matrix were seen, although there was a trend for greater mineralised matrix contact on the polished and 9V180s treated implants. Previous experiments demonstrated cells on the 9V treated surfaces were well spread and had significantly increased size and number of focal adhesions. This was regarded as indicating more successful cell adhesion. The above results demonstrate that this early trend disappeared in longer term culture did not persist in experiments in an animal model.
Uncemented implants are an important part of the arthroplasty armamentarium. Risk of aseptic loosening and failure of these components is related to initial osseointegration - the formation of a seamless bone-implant interface without interposition of fibrous tissue. Modification of the surface properties of titanium alloy, to enhance suitability for early osseointegration.Background
Aim
There have been marked changes in the management of Juvenile Idiopathic Arthritis (JIA) over recent decades, mainly with earlier use of methotrexate (MTX). Our aim was to describe orthopaedic interventions in a large group of adults with JIA followed up over several decades. This was a retrospective observational study of adult JIA patients attending a teaching hospital clinic, with information collated on JIA subtype, disease duration, orthopaedic interventions and exposure to MTX. The study included 144 patients with median disease duration of 19 years. Survival analysis showed that joint surgery was observed in the majority (75%) of patients with disease duration over 40 years with a trend for less joint surgery in patients with oligoarticular JIA. In total 41 patients (28.5%) had received joint surgery and 17/41(41%) have required multiple procedures. Of those who have required joint surgery, 20/41(48%) had started MTX in their adult years, with only 5/41 (12%), starting MTX prior to first joint replacement and none within five years of disease onset. Of the patients who have not had joint surgery to date, most (46/103, 45%) were receiving MTX or another immunosuppressive agent, in the majority of cases MTX was started within two years of disease onset. Many adults with JIA require joint replacement surgery and ongoing immunosuppressive treatments, emphasising that JIA is not a benign disease. Many patients who have had joint replacement surgery have had exposure to MTX albeit after many years after disease onset; it remains to be seen whether patients who have received MTX therapy early in their disease course will ultimately have less requirement for joint surgery.
Successful total knee arthroplasty design is related to the joint dynamics imposed by the design. This study examined the clinical and biomechanical performance of patients who received a PFC Sigma total knee implant (posterior cruciate substituting design). Radiographic, strength testing, gait pattern and clinical survey data were collected. Pre-operative and post-operative outcome measures were compared. Statistically significant differences were found on the pain, stiffness and physical function scales of the WOMAC as well as the knee and total score parameters of the Knee Society Score. Significant improvements were also seen on several gait pattern parameters. Factors such as implant design and surgical technique have been found to influence knee kinematics and kinetics thereby effecting patient function and implant survival after total knee arthroplasty. Numerous gait studies have reported a lack of normal gait pattern for TKA patients (Wilson et al., 1996; Andriacchi, 1993; Jevsevar et al., 1993). There is debate in the literature as to which design best improves patient function and implant survival, the posterior cruciate (PC) substituting or PC-retaining. The purpose of this study is to determine the clinical outcome and biomechanical performance of patients who receive PFC Sigma total knee arthroplasty. The PC substituting implant design provided significant improvements in clinical and gait outcomes at two years post-op in this patient sample. Patients experience significant pain and stiffness relief, and better functional outcomes. A cohort of eighteen total knee replacement patients were followed for two years post-operatively. Radiographic, strength testing, gait pattern and clinical survey data (SF36, WOMAC, Knee Society Score) were collected. Paired sample t-tests, repeated measures general linear modeling and principle component analyses comparing aged matched normals were conducted to evaluate pre-operative and post-operative outcomes. Statistically significant differences were found on the pain, stiffness and physical function scales of the WOMAC as well as the knee and total score parameters of the Knee Society survey. There were also significant improvements found on gait pattern parameters. Findings like these point to a need for larger population studies of patients with PC-substituting TKA.