Evaluate the outcome and complications of anterior pubic symphysis plating in the stabilisation of traumatic anterior pelvic ring injuries. All patients who underwent pubic symphysis plating in a tertiary referral unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded.Aim
Methods
There is controversy regarding the optimum method of stabilising traumatic anterior pelvic ring injuries. This study aimed to evaluate the role of pubic symphysis plating. All patients who underwent pubic symphysis plating in a regional pelvic and acetabular unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded. Out of 178 consecutive patients, 159 (89%) were studied for a mean of 37.6 months. There were 121 males and 38 females (mean age 43 years). Symphysis pubic fixation was performed in 100 AO-OTA type B and 59 type C injuries using a Matta symphyseal plate (n=92), reconstruction plate (n=65), or DCP (n=2). Supplementary posterior pelvic fixation was performed in 102 patients. 5 patients required revision for failure of fixation or symptomatic instability of the pubic symphysis. A further 7 patients had metalwork removed for other reasons. Metalwork breakage occurred in 63 patients (40%). 62 of these 63 patients were asymptomatic and metalwork was left in situ.Methods
Results
31% were Antero-Posterior Compression (APC) injuries, 37% Lateral Compression (LC) injuries and 32% Vertical Shear (VS) injuries. 32% of all patients reported significant new sexual problems (36% of males and 24% of females). Of the males, 31% reported erectile dysfunction (12% absolute impotence), 32% reported decreased arousal and 21% reported ejaculatory problems. Of the females, 16% reported decreased arousal, 5% reported anorgasmia and 3% reported painful orgasms. There were no reported cases of dyspareunia in the female patients. 41% of APC, 15% of LC and 39% of VS injuries reported significant new sexual problems (p=0.02, Chi-squared test). There was a 12% prevalence of significant new urological dysfunction in the entire cohort, with 27% of those with sexual dysfunction also reporting urological dysfunction. This compares with a 5% prevalence of urological dysfunction in patients without sexual dysfunction (p<
0.0001, Chi-squared test).
Suturing of portals following arthroscopic shoulder surgery is the standard method of closure, but may be unnecessary. We carried out a randomised controlled trial to compare patients whose arthroscopic portals were closed by suturing and those that were covered by a simple dressing. We randomised 60 patients undergoing diagnostic shoulder arthroscopy, arthroscopic subacromial decompression and arthroscopic acromio-clavicular joint excision. At 10 to 12 days following surgery, patients attended the GP surgery for a wound check and removal of sutures as required. At 3 weeks and 3 months every patient was reviewed by a designated, blinded, observer and the wounds assessed. The patients completed a questionnaire including visual analogue scores to determine their satisfaction with wound appearance and any complications such as infection. At 3 weeks and 3 months no patients had needed antibiotics with no wound erythema or signs of infection. The number of dressings needed was comparable in both groups (p=0.73). The difference in the level of patient satisfaction was not statistically significant in either group (p=0.46). The wound cosmesis score was not statistically different in either group (p=0.66) We conclude that both closure techniques were equivalent but the non-suture technique is cheaper with lower morbidity. From our study there is no need to suture shoulder arthroscopy portal wounds
We aimed to determine multi-modality outcomes in surgically treated patients with high energy pelvic ring injuries. A retrospective cohort study of all patients with pelvic ring fractures treated surgically within our specialist tertiary referral unit was undertaken between 1994 and 2007. Case-notes and radiographs were reviewed and patients were contacted by postal questionnaire. Outcome measures were return to work, return to pre-injury sports and social activities, and the Short Form-36 (SF-36) outcome tool. Injuries were classified using the Young and Burgess (YB) classifications. There was a response rate of 70% (145 of 209 patients), 74% of the study subjects were male. Average age at injury was 40 yrs (16–74 yrs). Average follow up was 5.3 yrs (1–12 yrs). There were 45 Antero-Posterior Compression (APC) injuries, 51 Lateral Compression (LC) injuries and 49 Vertical Shear (VS) injuries. 58% of the APC injuries had returned to work (including changed roles at work), compared with 68% of the LC injuries and 51% of the VS injuries. 27% of the APC injuries had returned to their pre-injury sports, compared with 39% of the LC and 33% of the VS injuries. 64% of the APC injuries had returned to their pre-injury social activities compared with 77% of the LC and 49% of the VS injuries. The SF-36 average Physical Functioning Score was better for the LC group (73.2) than the APC (61.7) and VS (63.3) groups. This general trend was repeated when the General Health and Social Functioning scores were reviewed. These results illustrate the long-term morbidity associated with pelvic ring injuries and relationship with injury subtypes. The LC injuries appear to have better outcomes with all outcome measures than APC and VS injuries. Further studies are underway to look at other factors and their relationship to outcomes.
Suturing of portals following arthroscopic shoulder surgery may be unnecessary. We carried out a randomised controlled trial to compare patients whose arthroscopic portals were closed by suturing and those that weren’t. We randomised 60 patients undergoing diagnostic shoulder arthroscopy, arthroscopic subacromial decompression and arthroscopic acromioclavicular joint excision. At 10 to 12 days following surgery patients attended the GP surgery for a wound check and removal of sutures as required. At 3 weeks and 3 months every patient was reviewed by a designated, blinded, observer and the wounds assessed. The patients completed a questionnaire including visual analogue scores to determine their satisfaction with wound appearance and any complications such as infection. At 3 weeks and 3 months no patients had needed antibiotics with no wound erythema or signs of infection. The number of dressings needed was comparable in both groups. The level of patient satisfaction was not statistically different in either group. (T-test 0.91, SD 15.16) The wound cosmesis score was not statistically different in either group. (T-test 0.29, SD 6.66) We conclude that both closure techniques were equivalent but the non-suture technique is cheaper with lower morbidity. From our study there is no need to suture shoulder arthroscopy portal wounds
There were 45 Antero-Posterior Compression (APC) injuries, 51 Lateral Compression (LC) injuries and 49 Vertical Shear (VS) injuries. 69% of the LC injuries had returned to some form of employment, compared with 58% of the APC injuries and 51% of the VS. 39% of the LC injuries had returned to their pre-injury sporting activities, compared with 27% of the APC and 33% of the VS. The average Physical Functioning Score of the SF-36 outcome tool was 73.2 for the LC injuries, 61.7 for the APC injuries and 63.3 for the VS injuries (scale 0–100, 100 representing best status). These trends were mirrored in the other outcome domains of the SF-36 tool.
Polyethylene liners of modular acetabular components wear and sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of liner revision. We prospectively followed up 1126 Harris-Gallante 1 metal backed, uncemented cups for between 9 and 19 years. 38 (3.4%) liners out of 1126 acetabular components wore and required revision. These revisions were then followed up for a mean of 4.8 years. The rate of dislocation was 28.9%. Nine of the dislocations were single dislocations and 2 were recurrent. The overall re-revision rate was 3 out of 38 total hip replacements (7.9%) at a mean follow up of 4.8 years. This gives a 92.1% survivorship at just under 5 years. In isolated liner revision we had a complication rate of 23%. In liner revision combined with stem revision we had a complication rate of 48%. Possible reasons for high dislocation rates are discussed. Leaving the well fixed acetabular shell in-situ leads to an increased risk of instability. However, this needs to be balanced against the otherwise low complication rate for liner revision. Patients should be consented accordingly
Polyethylene liners of modular acetabular components wear sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of revision. We prospectively followed up 1126 Harris-Galante I metal-backed, uncemented components for between nine and 19 years. We found 38 (3.4%) liners of 1126 acetabular components wore and required revision. These revisions were then followed up for a mean of 4.8 years. The rate of dislocation was 28.9%. Nine of the dislocations occurred once and two were recurrent. The overall secondary revision rate was three of 38 total hip replacements (7.9%) at a mean follow-up of 4.8 years. This gives a 92.1% survivorship (35 of 38) at under five years. In isolated revision of a liner, we had a complication rate of 23% (three of 13). In revision of a liner combined with revision of the femoral stem, there was a complication rate of 48% (12 of 25). We discuss possible reasons for the high dislocation rates. Leaving the well-fixed acetabular shell
Average post-op scoliosis 19.4 degrees. Average correction 65%. One patient required second operation for long screws. Four self limiting rninor complications. Average time to discharge eight days