Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 111 - 111
1 May 2016
Klinger C Dewar D Sculco P Lazaro L Ni A Thacher R Helfet D Lorich D
Full Access

Introduction

The vascular anatomy of the femoral head and neck has been previously reported, with the primary blood supply attributed to the deep branch of the Medial Femoral Circumflex Artery (MFCA). This understanding has led to development of improved techniques for surgical hip dislocation for multiple intra-capsular hip procedures including Hip Resurfacing Arthroplasty (HRA). However, there is a lack of information in the literature on quantitative analysis of the contributions of the Lateral Femoral Circumflex Artery (LFCA) to femoral head and neck. Additionally, there is a lack of detailed descriptions in the literature of the anatomic course of the LFCA from its origin to its terminal branches.

Materials & Methods

Twelve fresh-frozen human pelvic cadaveric specimens were studied (mean age 54.3 years, range 28–69). One hip per specimen was randomly assigned as the experimental hip, with the contralateral used as a control. Bilateral vascular dissection was performed to cannulate the MFCA and LFCA. Specimens were assigned as either LFCA-experimental or MFCA-experimental. All specimens underwent a validated quantitative-MRI protocol: 2mm slice thickness with pre- and post- MRI contrast sequences (Gd-DTPA diluted with saline at 3:1). In the LFCA-experimental group 15ml of MRI contrast solution was injected into the LFCA cannula. In the MFCA-experimental group 15ml of contrast solution was injected into the MFCA cannula. On the control hip contrast solution was injected into both MFCA and LFCA cannulas, 15ml each (30ml total for the control hip). Following MRI, the MFCA and LFCA were injected with polyurethane compound mixed with barium sulfate (barium sulfate only present in either MFCA or LFCA on each hip). Once polymerization had occurred, hips underwent thin-slice CT scan to document the extra- and intra-capsular course of the LFCA and MFCA. Gross dissection was performed to visually assess all intra-capsular branches of both the MFCA and LFCA and assess for extravasation. Quantitative-MRI analysis was performed based on Region of Interest (ROI) assessment. Femoral heads were osteotomized at the level of the largest diameter proximal to the articular margin and perpendicular to the femoral neck, for placement of a 360° scale. Measurements using the 360° scale were recorded. For data processing, we used right-side equivalents and integrated our 360° data into the more commonly used imaginary clock face.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 131 - 137
1 Jan 2009
Boraiah S Dyke JP Hettrich C Parker RJ Miller A Helfet D Lorich D

In spite of extensive accounts describing the blood supply to the femoral head, the prediction of avascular necrosis is elusive. Current opinion emphasises the contributions of the superior retinacular artery but may not explain the clinical outcome in many situations, including intramedullary nailing of the femur and resurfacing of the hip. We considered that significant additional contribution to the vascularity of the femoral head may exist. A total of 14 fresh-frozen hips were dissected and the medial circumflex femoral artery was cannulated in the femoral triangle. On the test side, this vessel was ligated, with the femoral head receiving its blood supply from the inferior vincular artery alone. Gadolinium contrast-enhanced MRI was then performed simultaneously on both control and test specimens. Polyurethane was injected, and gross dissection of the specimens was performed to confirm the extraosseous anatomy and the injection of contrast. The inferior vincular artery was found in every specimen and had a significant contribution to the vascularity of the femoral head. The head was divided into four quadrants: medial (0), superior (1), lateral (2) and inferior (3). In our study specimens the inferior vincular artery contributed a mean of 56% (25% to 90%) of blood flow in quadrant 0, 34% (14% to 80%) of quadrant 1, 37% (18% to 48%) of quadrant 2 and 68% (20% to 98%) in quadrant 3. Extensive intra-osseous anastomoses existed between the superior retinacular arteries, the inferior vincular artery and the subfoveal plexus.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 380 - 380
1 Sep 2005
Steinberg E Geller S Yacoubian S Shasha N Dekel S Lorich D
Full Access

Objective: To evaluate and present our experience using the expandable nail system for the treatment of tibial shaft fractures.

Design: Retrospective study.

Setting: Level 1 Trauma Center – University teaching hospital.

Methods: Fifty-nine consecutive patients treated by this nail system for tibia fracture, fifty-four were acute fractures and five non-unions that were not included in the study. Two nail diameters were used, 8.5mm and 10mm. Operation, hospitalization and healing times, reaming versus non-reaming, isolated versus multiple injuries and re-operations were recorded and analyzed statistically.

Results All fractures healed in an average time of 72 days. The average healing times for patients treated with an 8.5 mm and 10 mm nail were 77.2 days and 63.4 days respectively. Average operative time was 103 minutes if reamed and 56 minutes if unreamed. Average healing times were 65.4 if reamed and 79.5 days if unreamed. Hardware was removed in 6 patients, and one patient underwent exchange nailing due to a delayed union. Operative time was shorter in the motor-vehicle group, 74 minutes in comparison to 80 and 84 minutes for the fall and pedestrian group.

Conclusion: The expandable nail offers the theoretical advantages of improved load sharing and rotational control without the need for interlocking screws. This study demonstrates satisfactory healing and alignment for the treatment of tibial shaft fractures using this device.