Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 55 - 55
24 Nov 2023
Wildeman P Rolfson O Wretenberg P Nåtman J Gordon M Söderquist B Lindgren V
Full Access

Aim

Prosthetic joint infection (PJI) is a serious complication following total hip arthroplasty (THA) entailing increased mortality, decreased quality of life, and high healthcare costs. In 2009 a nationwide, multidisciplinary infection control program was launched in Sweden, PRISS, which aimed to reduce the PJI burden by 50%.

The primary aim was to investigate whether the PRISS project reduced PJI incidence after primary THA; the secondary aim was to evaluate other possible benefits of PRISS, such as shorter time to diagnosis.

Method

We obtained data on patients undergoing primary THA in Sweden (n = 45,723 patients, 49,946 THAs), 2012–2014. Using personal identity numbers, this cohort was matched with the Swedish Prescribed Drug Registry. Medical records of patients with ≥4 weeks antibiotic consumption were reviewed to verify PJI diagnosis (n = 2240, 2569 THAs).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 2 - 2
1 Dec 2021
Thompson O Stefánsdóttir A W-Dahl A Robertsson O Gordon M Lindgren V
Full Access

Aim

Strenuous efforts to minimize postoperative infection rates have been made, including the Swedish nation-wide initiative Prosthesis Related Infections Shall be Stopped (PRISS). The aim of this study was to calculate the incidence rate of periprosthetic joint infections (PJI) following primary total knee arthroplasty (TKA) before and after PRISS.

Method

All 45,438 primary TKAs registered in the Swedish knee arthroplasty register (SKAR) during 2007–2008 and 2012–2013 were included. Matched data on antibiotic prescriptions were obtained from the Swedish Prescribed Drug Register (SPDR). All patients with ≥28 days of continuous antibiotic treatment within 2 years of primary surgery had their medical charts reviewed to identify cases of PJI.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 34 - 40
1 Jan 2019
Kraus Schmitz J Lindgren V Janarv P Forssblad M Stålman A

Aims

The aim of this study was to investigate the incidence, risk factors, and outcome of venous thromboembolism (VTE) following anterior cruciate ligament (ACL) reconstruction in a nationwide cohort.

Patients and Methods

All ACL reconstructions, primary and revision, that were recorded in the Swedish Knee Ligament Register (SKLR) between 2006 and 2013 were linked with data from the Swedish National Board of Health and Welfare. The incidence of VTE was determined by entries between the day of surgery until 90 days postoperatively based on diagnosis codes and the prescription of anticoagulants. Risk factors, outcome, and the use of thromboprophylaxis were analyzed. Descriptive statistics with multivariate analysis were used to describe the findings.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 100 - 100
1 Feb 2017
Bragdon C Donahue G Lindgren V Galea V Madanat R Muratoglu O Malchau H
Full Access

Introduction

Complication and revision rates have shown to be high for all metal-on-metal (MoM) bearings, especially for the ASR Hip System (ASR hip resurfacing arthroplasty (HRA) and ASR XL total hip arthroplasty (THA)). This prompted the global recall of the ASR Hip System in 2010. Many studies have previously explored the association between female gender and revision surgery MoM HRA implants; yet less research has been dedicated to exploring this relationship in MoM THA.

The first purpose of this study was to assess the associations between gender and implant survival, as well as adverse local tissue reaction (ALTR), in patients with MoM THA. Secondly, we sought to report the differences between genders in metal ion levels and patient reported outcome measures (PROMs) in patients with MoM THA.

Methods

The study population consisted of 729 ASR XL THA patients (820 hips) enrolled from September 2012 to June 2015 in a multicenter follow-up study at a mean of 6.4 (3–11) years from index surgery. The mean age at the time of index surgery was 60 (22–95) years and 338 were women (46%). All patients enrolled had complete patient and surgical demographic information, blood metal ion levels and PROMs obtained within 6 months, and a valid AP pelvis radiograph dating a maximum of 2 years prior to consent. Blood metal ion levels and PROMs were then obtained annually after enrollment. A sub-set of patients from a single center had annual metal artifact reduction sequence (MARS) MRI performed and were analyzed for the presence of moderate-to-severe ALTR.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 128 - 128
1 Feb 2017
Bragdon C Galea V Donahue G Lindgren V Troelsen A Marega L Muratoglu O Malchau H
Full Access

Introduction

Studies of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) have reported high complication and failure rates due to elevated metal ion levels. These rates were shown to be especially high for the Articular Surface Replacement (ASR) HRA, possibly due to its unique design. Associations between metal ion concentrations and various biological and mechanical factors have been reported. Component positioning as measured by acetabular inclination has been shown to be of especially strong consequence in metal ion production in ASR HRA patients, but few studies have evaluated acetabular anteversion as an independent variable.

The primary objective of this study was to evaluate the associations between component orientation, quantified by acetabular inclination and anteversion, and blood metal ions. Secondly, we sought to report whether conventional safe zones apply to MoM HRA implants or if these implants require their own positioning standards.

Methods

We conducted a multi-center, prospective study of 512 unilateral ASR HRA patients enrolled from September 2012 to June 2015. At time of enrollment our patients were a mean of 7 (3–11.5) years from surgery. The mean age at surgery was 56 years and 24% were female. All subjects had complete demographic and surgical information and blood metal ions. In addition, each patient had valid AP pelvis and shoot-though lateral radiographs read by 5 validated readers measuring acetabular abduction and anteversion, and femoral offset. A multivariate logistic regression was used with high cobalt or chromium (greater than or equal to 7ppb) as the dependent variable. The independent variables were: female gender, UCLA activity score, age at surgery, femoral head size, time from surgery, femoral offset, acetabular abduction, and acetabular anteversion.