header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 2 - 2
1 Dec 2022
Schneider P Bergeron S Liew A Kreder H Berry, G
Full Access

Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes.

Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model.

A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group.

This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 77 - 77
1 Dec 2022
Schneider P Bergeron S Liew A Kreder H Berry G
Full Access

Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes.

Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model.

A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group.

This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 57 - 57
1 Mar 2021
Sanders E Dobransky J Finless A Adamczyk A Wilkin G Liew A Gofton W Papp S Beaulé P Grammatopoulos G
Full Access

Management of acetabular fractures in the elderly population remains somewhat controversial in regards to when to consider is open reduction internal fixation (ORIF) versus acute primary total hip. study aims to (1) describe outcome of this complex problem and investigate predictors of successful outcome.

This retrospective study analyzes all acetabular fractures in patients over the age of 60, managed by ORIF at a tertiary trauma care centre between 2007 and 2018 with a minimum follow up of one year. Of the 117 patients reviewed, 85 patients undergoing ORIF for treatment of their acetabular fracture were included in the analysis. The remainder were excluded based management option including acute ORIF with THA (n=10), two-stage ORIF (n=2), external fixator only (n=1), acute THA (n=1), and conservative management (n=1). The remainder were excluded based on inaccessible medical records (n=6), mislabelled diagnosis (n=6), associated femoral injuries (n=4), acetabular fracture following hemiarthroplasty (n=1). The mean age of the cohort is 70±7 years old with 74% (n=62) of patients being male. Data collected included: demographics, mechanism of injury, Charlson Comorbidity Index (CCI), ASA Grade, smoking status and reoperations. Pre-Operative Radiographs were analyzed to determine the Judet and Letournel fracture pattern, presence of comminution and posterior wall marginal impaction. Postoperative radiographs were used to determine Matta Grade of Reduction. Outcome measures included morbidity-, mortality- rates, joint survival, radiographic evidence of osteoarthritis and patient reported outcome measures (PROMs) using the Oxford Hip Score (OHS) at follow-up. A poor outcome in ORIF was defined as one of the following: 1) conversion to THA or 2) the presence of radiographic OA, combined with an OHS less than 34 (findings consistent with a hip that would benefit from a hip replacement). The data was analyzed step-wise to create a regression model predictive of outcome following ORIF.

Following ORIF, 31% (n=26) of the cohort had anatomic reduction, while 64% (n=54) had imperfect or poor reduction. 4 patients did not have adequate postoperative radiographs to assess the reduction. 31 of 84 patients undergoing ORIF had a complication of which 22.6% (n=19) required reoperation. The most common reason being conversion to THA (n=14), which occurred an average of 1.6±1.9 years post-ORIF. The remainder required reoperation for infection (n=5). Including those converted to THA, 43% (n=36) developed radiographic OA following acetabular fracture management. The mean OHS in patients undergoing ORIF was 36 ± 10; 13(16%) had an OHS less than 34. The results of the logistic regression demonstrate that Matta grade of reduction (p=0.017), to be predictive of a poor outcome in acetabular fracture management. With non-anatomic alignment following fixation, patients had a 3 times greater risk of a poor outcome. No other variables were found to be predictive of ORIF outcome.

The ability to achieve anatomic reduction of fracture fragments as determined by the Matta grade, is predictive of the ability to retain the native hip with acceptable outcome following acetabular fracture in the elderly. Further research must be conducted to determine predictors of adequate reduction in order to identify candidates for ORIF.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 75 - 75
1 Dec 2016
Sellan M Bryant D Tieszer C MacLeod M Papp S Lawendy A Liew A Viskontkas D Coles C Carey T Gofton W Trendholm A Stone T Leighton R Sanders D
Full Access

The benefit of using a long intramedullary device for the treatment of geriatric intertrochanteric hip fractures is unknown. The InterTAN device (Smith and Nephew, Memphis TN) is offered in either Short (180–200 mm) or Long (260–460 mm) constructs and was designed to provide stable compression across primary intertrochanteric fracture fragments. The objective of our study was to determine whether Short InterTANs are equivalent to Long InterTANs in terms of functional and adverse outcomes for the treatment of geriatric intertrochanteric hip fractures.

108 patients with OTA classification 31A–1 and 31A–2 intertrochanteric hip fractures were included in our study and prospectively followed at one of four Canadian Level-1 Trauma Centres. Our primary outcomes included two validated primary outcome measures: the Functional Independence Measure (FIM), to measure function, and the Timed Up and Go (TUG), to measure motor performance. Secondary outcome measures included blood loss, length of procedure, length of stay and adverse events. A pre-injury FIM was measured by retrospective recall and all postoperative outcomes were assessed on postoperative day 3, at discharge, at 6 weeks, 3 months, 6 months and 12 months postoperatively. Unpaired t-tests and Chi-square tests were used for the comparison of continuous and categorical variables respectively between the Short and Long InterTAN groups. A statistically significant difference was defined as p<0.05.

Our study included 71 Short InterTAN and 37 Long InterTAN patients with 31A–1 and 31A–2 intertrochanteric hip fractures. Age, sex, BMI, side, living status and comorbidities were similar between the two groups. The mean operative time was significantly lower in the Short InterTAN group (61 mins) as compared to the Long InterTAN group (71 mins)(p0.05). There were 5 periprosthetic femur fractures in the short InterTAN group versus 1 in the long InterTAN group. Non-mechanical adverse outcomes such as myocardial infarction, pulmonary embolism, urinary tract infections, pneumonia and death all had similar incidence rates between the two InterTAN groups.

Both the Short and Long InterTAN patient cohorts displayed similar improvements in performance and overall function over the course of a year following intertrochanteric hip fracture fixation. The recorded operative times for Short InterTAN fixation were significantly shorter than those recorded for the Long InterTAN patients. Alternatively, a significantly higher proportion of Short InterTAN patients sustained periprosthetic femur fractures within a year of implantation as compared to the Long InterTAN group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 31 - 31
1 Nov 2016
Morellato J Louati H Bodrogi A Stewart A Papp S Liew A Gofton W
Full Access

Traditional screw fixation of the syndesmosis can be prone to malreduction. Suture button fixation however, has recently shown potential in securing the fibula back into the incisura even with intentional malreduction. Yet, if there is sufficient motion to aid reduction, the question arises of whether or not this construct is stable enough to maintain reduction under loaded conditions. To date, there have been no studies assessing the optimal biomechanical tension of these constructs. The purpose of this study was to assess optimal tensioning of suture button fixation and its ability to maintain reduction under loaded conditions using a novel stress CT model.

Ten cadaveric lower limbs disarticulated at the knee were used. The limbs were placed in a modified external fixator frame that allows for the application of sustained torsional (5 Nm), axial (500 N) and combined torsional/axial (5Nm/500N) loads. Baseline CT scans of the intact ankle under unloaded and loaded conditions were obtaining. The syndesmosis and the deltoid ligament complex were then sectioned. The limbs were then randomised to receive a suture button construct tightened at 4 kg force (loose), 8 kg (standard), or 12 kg (maximal) of tension and CT scans under loaded and unloaded conditions were again obtained. Eight previously described measurements were taken from axial slices 10 mm above the tibiotalar joint to assess the joint morphology under the intact and repair states, and the three loading conditions: a measure of posterolateral translation (a, b), medial/lateral translation (c, g), a measure of anterior-posterior translation (f), a ratio of anterior-posterior translation (d/e), an angle (Angle 1) created by a line parallel to the incisura and the axis of the fibula, and an angle (Angle 2) created between the medial surfaces of two malleoli. These measurements have all been previously described. Each measurement was taken at baseline and compared with the three loading scenarios. A repeated measures ANOVA with a Bonferroni correction for multiple comparisons was used to test for significance.

Significant lateral (g, maximum 5.26 mm), posterior (f, maximum 6.42 mm), and external rotation (angle 2, maximum 11.71°) was noted with the 4 kg repair when compared to the intact, loaded state. Significant posterior translation was also seen with the both the 8 kg and 12 kg repairs, however the incidence and magnitude was less than with the 4 kg repair. Significant overcompression (g, 1.69 mm) was noted with the 12 kg repair.

Suture button constructs must be appropriately tensioned to maintain reduction and re-approximate the degree of physiological motion at the distal tibiofibular joint. If inserted too loosely, these constructs allow for supraphysiologic motion which may have negative implications on ligament healing. These constructs also demonstrate overcompression of the syndesmosis when inserted at maximal tension however the clinical effect of this remains to be determined.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 264 - 264
1 Jul 2011
Bayley G Gofton W Liew A Papp S
Full Access

Purpose: To compare the accuracy of post-operative plain radiographs versus computed tomography (CT) scans for the assessment of acetabular fracture reduction.

Method: A retrospective assessment of sixty-four fractures in sixty-two patients was performed independently by three orthopedic trauma surgeons. Pre-operative CT scans and three plain radiographs (one anteroposterior pelvis and two Judet views) were used to classify the fracture pattern and measure pre-operative articular step and gap. Post-operative reduction quality was assessed using three plain radiographs and an axial CT assessing for step, gap, intra-articular hardware or fragments and necessity to re-operate.

Results: Fracture patterns were as follows; posterior wall (n=10), posterior column (n=1), anterior wall (n=4), anterior column (n=1), transverse (n=12), posterior column posterior wall (n=4), transverse posterior wall (n=8), T-type (n=6), anterior column posterior hemi-transverse (n=5) and associated both column (n=11). Pre-operatively, the average step and gap on plain radiographs was 8.7 mm (±SD) and 15.3 mm (±SD). Post-operatively, the average step and gap was 0.6 mm (SD) and 0.9 mm (SD) based on 46 patients. The assessment was not possible in 18 patients due to overlying hardware. Using plain radiographs, one patient was found to have an inadequate reduction (> 2mm step and/or > 3mm gap). Post-operative measurement of step and gap by CT scan were 1.2 mm (SD) and 2.3 mm (SD) respectively. Using CT scans, eight patients were found to have either an inadequate reduction, intra-articular hardware or retained fragments. Computed tomography demonstrated 2 times more step and gap compared to plain radiographs.

Conclusion: Post-operative CT was found to be more sensitive than plain radiographs to assess the quality of acetabular fracture reduction. Plain radiographs detected only 1 out of 8 cases where further operative intervention may have been beneficial. Given the consequences of missing an unacceptable reduction, intra-articular hardware, or retained intra-articular fragments, it is recommended that all fractures should be assessed postoperatively with CT unless the patient is not a candidate for further surgery for reasons independent of reduction quality. The benefits of post-operative CT imaging in acetabular fractures likely outweigh the cost and radiation exposure associated with its use.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 265 - 265
1 Jul 2011
Wilkin G Papp S Gofton W Liew A
Full Access

Purpose: The purpose of this study was to review our results in patients with pilon fractures treated with ORIF in which surgical planning involved multiple skin incisions, ensuring that the distance incisions overlapped was less than the distance between them. We hypothesized that soft-tissue complications would be minimal despite incisions placed < 7-cm apart.

Method: A retrospective chart review identified 37 pilon fractures in 32 patients treated by three orthopedic traumatologists at The Ottawa Hospital between August 2000 and February 2007. Follow-up included measurements of incision placement and functional outcome measures.

Results: There were nine OTA type B and 28 OTA type C fractures; 28 were closed and nine were open. The mean age was 46.5 ±14.5 years, and average follow-up was 3.2 ±1.7 years. Of the patients reviewed, the average number of incisions was 3.7 ±1.1. The average overlap between incisions was 4.6-cm ±1.9 and the average skin bridge between incisions was 5.9-cm ±1.9, with 80% of the skin bridges < 7-cm. Average ROM was 4.3° ±7.1 dorsiflexion and 39.1° ±11.6 plantarflexion. The mean AMA lower extremity impairment score was 18.9% ±12.4, and mean SIP ambulation score was 9.6 ±8.8. Complications included two superficial infections, one deep infection, and three non-unions. There were no cases of wound dehiscence or necrosis, or cases requiring revision soft-tissue coverage. These outcomes were comparable to recent reports with similar injuries.

Conclusion: With careful planning and good soft-tissue management, incisions can be placed to maximize articular exposure based on fracture lines. It does not appear that the dogma of keeping incisions > 7-cm apart must be followed in most cases. Prudent surgical timing and meticulous soft-tissue handling can allow for multiple incisions to be placed as necessary for fracture reduction and optimal fixation while maintaining a low rate of complications.