Unstable intertrochanteric hip fractures (AO 31A2) continue to be a challenge, as non-locking implants have shown a considerable rate of loss of reduction. Intramedullary fixation has been recommended, although screw cut-out has been identified as problematic. This study was performed to ascertain whether treatments with the established proximal femoral nail (PFN) and the newer PFNA with blade design (proximal femoral nail antirotation) have advantages over the use of the Percutaneous Compression Plate (PCCP, developed by Gotfried). Cohort study. Between March 2003 and March 2008, 134 patients with unstable fractures were treated with a PCCP, (n=44, 78.3 yrs, ASA 2.8), a PFN (n=50, 77.2 yrs, ASA 2.8), or a PFNA (n=40, 75.8 yrs, ASA 2.6). The patients (31 PCCP, 33 PFN, 30 PFNA) were then reexamined clinically and radiologically after approximately 21 months.Introduction
Methods
Aim of this study was to find out which factors influence the outcome after both column fractures of the acetabulum. We performed a retrospective analyse of 115 patients with both column acetabular fractures. The period between the injury and follow-up ranges between 2 and 19 years, 5,7 years on average. The initial displacement, the presence of a dislocation of the hip and fractures of the femoral head were analyzed on the initial radiographs. Postoperative displacement was classified according the classification of Matta. The common classifications of Helfet (posttraumatic arthrosis), Ficat/Arlet (femur head necrosis) and Brooker (periarticular calcification) were used to radiologically classify the long term results. Statistics were performed by the Chi-square-test.Aim of the study
Methods
The additive use of an external modular device may improve dorsal compression forces in pelvic external fixation. This would improve the efficiency of indirect reduction and stabilization with an anterior pelvic external fixator. The purpose of this study was to determine the forces of the posterior pelvis achieved by a new device improving the application of a supraacetabular anterior external fixator compared with other constructs. Synthetic pelvic models were used. Complete pelvic ring instability was created by symphyseal and unilateral sacroiliac joint disruption. Four different constructs of fixation were tested. A pressure-sensitive film was placed in the sacroiliac joint. The constructs were applied in a standardized way. The maximum sacroiliacal compression loads (N) of each trial was recorded. Statistics was performed with the student t-test.Objectives
Material and Method
Overlooked compartment syndrome represents a devastating complication for the patient. Invasive compartment pressure measurement continues to be the gold standard. However, repeated measurements in uncertain cases may be difficult to achieve. We developed a new, noninvasive method to assess tissue firmness by pressure related ultrasound. Decreased tissue elasticity by means of rising compartment pressures was mimicked by infusion of saline directly into the anterior tibial compartment of 6 human specimens post mortem. A pressure transducer (Codman) monitored the pressure of the anterior tibial compartment. A second transducer was located in a saline filled ultrasound probe head to allow a simultaneous recording of the probe pressure provoked by the user. The ultrasound images were generated at 5 and 100mmHg probe pressures to detect the tissue deformity by B-mode ultrasound. The fascial displacement was measured before and after compression (d). Subsequently, increments of 5mmHg pressure increases were used to generate a standard curve (0–80mmHg), thus mimicking rising compartment pressures. The intra-observer reliability was tested using 10 subsequent measurements. A correlation was determined between d and the simulated intacompartmental pressure (ICP) in the compartment. The Pearson correlation coefficient (r) was calculated. The reliability determined by the kappa value and a regression analysis was performed.Background
Methods