header advert
Results 1 - 20 of 37
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 85 - 85
1 Mar 2012
Sharma S Levy O
Full Access

Objective

Arthroscopic rotator cuff repairs now yield a similar footprint as open procedures with several advantages, including reduced tissue trauma, post-operative pain, swelling, and concern about the deltoid attachment. We present a new simple and reproducible technique for arthroscopic rotator cuff repair.

Methods

Sutures are placed through the full thickness of the rotator cuff. The suture is tied in the following manner:

Traction is released, the assistant maintaining the arm in abduction and applying tension on the anterior cuff sutures while the posterior cuff sutures are tied. The procedure is repeated for the anterior cuff suture; and

One suture strand from the anterior cuff and one suture strand from the posterior cuff are tied. The procedure is then repeated using the second strand from the anterior cuff and second suture strand from the posterior cuff. This suture and knot tying technique snugs the cuff down to the prepared tuberosity and restores the articular footprint of the cuff. This study retrospectively evaluated the clinical outcome of 170 patients who underwent arthroscopic cuff repair using this technique.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1341 - 1347
1 Oct 2008
Levy O Venkateswaran B Even T Ravenscroft M Copeland S

We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans.

Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six massive (> 5 cm in diameter) tears. There was a statistically significant increase in the size of the tear with increasing age (p = 0.0048).

The mean pre-operative Constant score was 41.4 points (95% confidence interval, 37.9 to 44.9), which improved to 84.5 (95% confidence interval, 82.2 to 86.9). A significant inverse association (p = 0.0074), was observed between the size of the tear and the post-operative Constant score, with patients having smaller tears attaining higher Constant scores after repair. Post-operatively, 80 patients (78.4%) were able to resume their occupations and 84 (82.4%) returned to their pre-injury leisure activities. Only eight (7.8%) of 102 patients were not satisfied with the outcome.

Recurrent tears were detected by ultrasound in 19 (18.6%) patients, and were generally smaller than the original ones. Patients with recurrent tears experienced a mean improvement of 31.6 points (95% confidence interval, 23.6 to 39.6) in their post-operative Constant scores. Those with intact repairs had significantly improved (p < 0.0001) Constant scores (mean improvement 46.3 points, 95% confidence interval, 41.9 to 50.6). Patient satisfaction was high in 94 cases (92%), irrespective of the outcome of the Constant score. Recurrent tears appear to be linked to age-related degeneration.

Arthroscopic repair of the rotator cuff leads to high rates of satisfaction (92%) and good functional results, albeit with a recurrence rate of 18.6% (19 of 102).


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 216 - 216
1 Jul 2008
Venkateswaran B Montgomery A Zaman T Even T Copeland S Levy O
Full Access

The purpose of this study is to report the 1 to 5 year results of arthroscopic Rotator Cuff repairs.

Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up. Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded.

The mean follow up time was 23.8 months (range 12–61). Mean age was 57.3 years (range 23–78). 47% had a history of trauma. There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small. Isolated Supraspinatus (SSP) tear was recorded in 83.5% and subscapularis tear in 7 %. A combination of SSP tear with infraspinatus and teres minor was found in 9.6%.

86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair.

The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 re-tears (19.6%). eight of the 102 patients were not satisfied. Five of these patients had revision operation.

Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results with 20% re-tear rate, while offering all the advantages of arthroscopic surgery.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 355 - 355
1 Jul 2008
Levy O Even T Raj D Abrahams R Webb M Pearse E Copeland S
Full Access

Considerable controversy remains in the literature as to whether hemiarthroplasty or total shoulder arthroplasty (TSA) is the better treatment option for patients with shoulder arthritis. Several cohort studies have compared the outcomes of stemmed hemiarthroplasty with those of stemmed TSA and had inconsistent conclusions as to which procedure is best. However, these studies suggest that stemmed TSA provided better functional outcome. 340 CSRA cases were performed between 1987–2003, 218 Hemiarthroplasty – Humeral Surface Arthroplasty (HSA) and 122 TSA. There was very little difference in the functional outcome and pain in patients with and without a glenoid implant early, as well as, later after surgery. Mean post-operative Constant score for TSA was 85.0% (59.8 points) and for HSA patients 86.8% (62.3 points) with no statistically significant differences (t-test, p=0.4821). A highly significant difference between the overall proportions of revised cases was observed, with (21/122) 17.2% and (6/218) 2.8% of TSA and HSA cases revised, respectively (p< 0.0001). Further, HSA prostheses survive significantly longer than TSA prostheses. The difference between the survival curves was highly significant, both in the earlier post-operative period (Wilcoxon’s test, p=0.0053) as well as the later on (Log-rank test, p=0.0028). Long-term survival of total joint replacement is related to polyethylene wear debris, and therefore its use should be avoided if possible. The difference between our series and those with stemmed prostheses may be due to the fact that with surface replacement the normal anatomy for each patient can be mimicked better than with the stemmed prostheses and there is substantially less place for error as in stem positioning, head sizing or wrong version that may lead to glenoid erosion and less favourable result. Our current practice is and we suggest performing Copeland humeral surface replacement without insertion of glenoid prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 893 - 898
1 Jul 2008
Levy O Relwani J Zaman T Even T Venkateswaran B Copeland S

The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue.

Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall.

The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p < 0.0001).

Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 351 - 351
1 Jul 2008
Webb M Even T Raj D Abrahams R Copeland S Levy O
Full Access

Introduction Pridie and Steadman independently noticed the development of a smooth layer of fibrocartilage when treating exposed subchondral bone in the knee using their techniques of drilling or microfracture respectively. Since 1997, patients presenting to our unit for a Copeland cementless Surface Replacement Arthroplasty (CSRA) with a congruent glenohumeral joint have routinely undergone biological resurfacing of the glenoid using a technique similar to that described by Pridie and Steadman. We present this technique of glenoid resurfacing, the histological and surgical outcomes in a consecutive group of patients.

Methods/Results Between 1987 and 2002, 218 CSRA were performed without replacing the glenoid. From 1997, 133 CSRA have been performed with multiple drilling of the glenoid face with a guide wire through the subchondral bone in to the underlying soft cancellous bone to stimulate bleeding. This causes formation of a fibrocartilaginous layer – biological resurfacing. 9 (6.8%) of the patients with biological resurfacing have subsequently undergone a shoulder arthroscopy for postoperative impingement pain. This allowed us to evaluate the glenoid surface – macroscopically a layer of cartilage was noted in all patients, intraoperative biopsies have confirmed this layer to be fibrocartilage microscopically. In the biological resurfacing group, the mean postoperative Constant score (CS) is 86.9 (age/sex adjusted), with a mean improvement in CS of 71.0. 3 (2.3%) patients have required revision.

Conclusion Our results confirm that glenoid drilling at the time of CSRA leads to the formation of a fibro-cartilaginous layer over the glenoid, with significant improvements in Constant scores and functional outcomes. These results are comparable to other published results for total shoulder replacement with polyethylene resurfacing of the glenoid and better than patients that have undergone stemmed shoulder hemiarthroplasty.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 355 - 355
1 Jul 2008
Mullett H Venkateswaran V Even T Massoud S Levy O Copeland S
Full Access

Arthroscopic rotator cuff repair has evolved significantly in the last decade and has become a standard treatment. Satisfactory results of arthroscopic subacromial decompression (ASD) in the treatment of rotator cuff tears have also been reported (1). The aim of this study was to compare the outcome following arthroscopic repair versus decompression alone in patients with small & medium rotator cuff tears (Classification of Post, Silver & Singh (2). There were 114 patients in the ASD group and 96 in the Arthroscopic rotator cuff repair group (RCR). The groups were statistically comparable in terms of patient age & gender. Clinical follow-up was performed at a minimum of 12 months post -operatively (average 36 months). The average Post-op Constant score was 69.8 for the ASD group and 86.4 for the RCR group. The average post-op pain score (S.D) in the ASD group was 10.9 (± 4.3) and in the RCR group was 13.6 (± 3.1). Post operative strength was 7.6 (± 3.6) in the ASD group and 16.7 (± 5.4) in the RCR group.26 patients (22.8%) in the ASD group and 3 (3.3%) of the RCR group required futher surgery. Patient satisfaction (maximum 10 points) was 7.4% in the ASD group and 8.9 (± 1.4) in the RCR. The results of this study support arthroscopic rotator cuff repair. Shoulder strength is improved and there is significant reduction in the need for revision surgery.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 359 - 359
1 Jul 2008
Webb MR Bottomley N Copeland SA Levy O
Full Access

Introduction The value of collecting continuous prospective patient data, including operation records and outcome scores, is well known. In 1994, a systematic prospective patient data collection was initiated on all patients attending the Reading Shoulder Unit (RSU). Initially this was done with hand written records. In 1995 a Windows Access ® database was formulated on a portable laptop. This was used continuously through until September 2005 when an Internet web-based database was introduced. We present this collective data and trends in practice from a busy shoulder unit over this decade. Results Between 1995 and 2005, 10005 entries were made to the Reading Shoulder Unit database. 3233 patient visits to outpatient clinics were recorded. 6772 operations were recorded – this includes: arthroscopic decompressions (ASD) + AC joint excisions − 3514, MUA for frozen shoulder 842, shoulder arthroplasty 432, open stabilisation 356, arthroscopic stabilisation 192, arthroscopic rotator cuff repair (RCR) 402, open cuff repair 290, arthroscopic capsular release 78 and 248 trauma cases. Changes in the unit practice include the move from open to arthroscopic reconstructive surgery (RC and stabilisation), RCR rather than ASD alone in elderly patients with impingement and cuff weakness, and repairing partial rotator cuff tears when previously we did not. Conclusions With over 10000 continuous and prospective entries – the RSU database is invaluable for continuous audit of practice and assessment of outcomes of the different procedures. Several practices have changed through the decade; most notably from predominately open reconstructive surgery through to arthroscopic reconstructive surgery. We would recommend to every surgeon and unit to collect his own data prospectively to enable him to analyse and assess his results.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1466 - 1469
1 Nov 2007
Mullett H Levy O Raj D Even T Abraham R Copeland SA

We describe the results of Copeland surface replacement shoulder arthroplasty using the mark III prosthesis in patients over 80 years of age. End-stage arthritis of the shoulder is a source of significant pain and debilitating functional loss in the elderly. An arthroplasty offers good relief of pain and may allow the patient to maintain independence. The risk-benefit ratio of shoulder replacement may be felt to be too high in an elderly age group, but there is no published evidence to support this theory. We have assessed whether the procedure was as reliable and safe as previously seen in a younger cohort of patients. Between 1993 and 2003, 213 Copeland surface replacement arthroplasty procedures were performed in our unit, of which 29 (13.6%) were undertaken in patients over the age of 80. This group of patients was followed up for a mean of 4.5 years (2.1 to 9.3). Their mean age was 84.3 years (81 to 93), the mean operating time was 40 minutes (30 to 45) and the mean in-patient stay was five days (2 to 21). There were no peri-operative deaths or significant complications. The mean Constant score adjusted for age and gender, improved from 15.1% to 77%. Copeland surface replacement shoulder arthroplasty may be performed with minimal morbidity and rapid rehabilitation in the elderly.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 345 - 345
1 May 2006
Levy O Venkateswaran B Montgomery A Zaman T Even T Copeland S
Full Access

Arthroscopic Rotator cuff repair is gaining popularity in recent years; however, the results of arthroscopic repairs are yet to be reported. Between November 2001 to May 2003, 115 consecutive patients were operated (73 males and 42 females) with arthroscopic repair. 13 patients were lost to follow up, leaving 102 patients available for follow up.

The mean follow up time was 23.8 months (range 12–61). There were 107 patients (95.5%) with full thickness tears and 5 (4.5%) had partial thickness tears. Of the full thickness tears, 8 (7.6%) were massive in size, 36 (34%) large, 44 (41.5%) medium and 18(17%) small.

Mean age was 57.3 years (range 23–78). 47% had a history of trauma.

Mainly Supraspinatus (SSP) tear was recorded in 83.5% and isolated subscapularis tear in 7%. A combination of SSP tear with infraspinatus and teres minor minor (posterior tear) was found in 9.6%.

86% had Acromioplasty (ASD) with or without an AC joint excision arthroplasty. Two patients had Bankart repairs in addition at the time of cuff repair.

Patients were evaluated using the Constant score, satisfaction levels and ultrasound scan to evaluate cuff integrity. Failures were defined as dissatisfied patients and those who had had a re-operation. Re-tear rate was recorded.

The mean pre op Constant score was 40.9 points (95% CI 37.3 to 44.5), which had improved to 84.8 (CI 82.2 to 86.9) at last follow-up. 78% returned to same work and 82% returned to pre injury leisure activity. There were 20 ultrasound demonstrated re-tears (19.6%). However, the majority of patients with radiological re-tears had good function, pain relief and were satisfied. Eight of the 102 patients were not satisfied. Five of these patients had revision operation.

Arthroscopic cuff repair shows high satisfaction rate (92%) and good functional results while offering all the advantages of arthroscopic surgery.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 346 - 346
1 May 2006
Levy O Raj D Copeland S
Full Access

Copeland Surface replacement arthroplasty provides a good outcome in cases of arthritis. However, the limitation of use of this prosthesis is severe bone loss of the humeral head.

We describe the use of Copeland Surface Replacement Shoulder Arthroplasty in cases of severe humeral head destruction extending more than 50% of the humeral head. The bone deficiency was reconstructed with the autograft from the reaming and reshaping of the humeral head and a synthetic bone graft substitute (Tricalcium phosphate granules (Biosorb)) mixed with the patient’s blood.

We report preliminary results in 8 cases. 3 males and 4 females (One patient bilateral). The average age was 48 years ( 22–76 years). 5 cases had Posttraumatic avascular necrosis of humeral head, two patients had locked posterior fracture dislocation with loss of more than 50% of the humeral head and one patient with severe juvenile rheumatoid arthritis.

In this series the remaining bone of humeral head was less than 50% ranging between 30–50% (average 38%).

The patients were followed clinically and radiographically. The average follow–up was 10.6 months (range: 5 to 15 months).

All patients had substantial improvement in there shoulder function and pain. All the patients were very satisfied. Average pre-op constant score was 9.3 points (range: 9–14). At the latest follow-up the average constant score was 59 (range: 36–74). Age and sex adjusted constant score was 68.6 (range: 37– 87).

Radiographically we observed good incorporation of the Bone graft substitute with no signs of loosening or any lucencies under the prosthesis.

These are early and encouraging results in this group of young patients with severe destruction of the humeral head. It seems like it may provide a good bone preserving solution in these cases and extend the frontiers for the surface replacement of the shoulder.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 384 - 384
1 Sep 2005
Levy O Venkateswaran B Zaman T Even T Kapila A Bhargava A Copeland S
Full Access

Introduction: Laser Doppler Flowmetry (LDF) is an established technique for the measurement of perfusion in tissues, which has been applied in animal and human studies. Despite many studies the implications of perfusion and blood flow abnormalities in the rotator cuff (RC) in vivo are not clearly understood. This study aims to assess the blood flow in the normal and diseased RC using Laser Doppler Flowmetry (LDF) technique.

Methods: With Ethics approval and informed consent patients undergoing arthroscopy for impingement or cuff tear (diseased cuff) or for shoulder instability (normal cuff) were recruited. Following diagnostic arthroscopy and bursoscopy measurements of the blood flux in the RC using the LDF were made at 6 points. Five of these were in the cuff over a 4 cm2 area from the insertion at the greater tuberosity (A,E – @ Tuberosity level, C-Muscelotendinous junction, B,D – between the two) and one (F) in the deep surface. Diseased RC were subgrouped into mild (B1), moderate (B2) and severe (B3- cuff tear) impingement grades (Copeland-Levy Classification). The arthroscopy, grading, and probe placement were made by the two senior authors. LDF flux (unit of measurement of the perfusion – LDFf) was recorded over 30 seconds at each measurement point. The mean of these readings was calculated.

Results: 56 patients were recruited. 35 Males (62.5%) and 21 Females (37.5%).

336 measurements were recorded.

The observed mean LDFf was 32.8 (27.4–38.1; 95% CI) , 25.4 (22.4–28.5) and 43.1 (37.8–48.4; 95% CI) For Normal, Impingement and Tear cases, respectively (p< 0.0001, One-way ANOVA).

The LDFf was lowest in the Impingement without tear grade (B2) with a statistically significant increase at the edges of a cuff tear.

Conclusion: Preliminary recordings of LDF show changes are in keeping with current knowledge of the pathology. LDFf decreases with advancing impingement, being least affected in the musculotendinous junction. There is a substantial increase in LDFf at the edges of RC tears. This might reflect an attempted reparative response.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 384 - 384
1 Sep 2005
Levy O Roberts S Copeland S
Full Access

Introduction: Massive irreparable degenerative rotator cuff tears are amongst the most difficult conditions for treatment in shoulder surgery. These involve usually elderly patients, which present with severely painful and restricted active shoulder movement. These patients have low demand from their shoulders, mainly for pain relief and performing their simple activities of daily living. Major surgery for major tendon transfer will not be advisable in these cases in view of the morbidity involved and the questionable outcome. We suggest a simple non-surgical rehabilitation treatment consisting on anterior deltoid strengthening exercises in the supine position for re-education of the anterior deltoid to compensate for the absent rotator cuff.

Methods: 17 patients with degenerative (non traumatic) Massive irreparable rotator cuff tears were recruited. They were all greater than 70 years of age and of mixed gender. Patients were English speaking, had full mental faculties and gave informed consent. They suffered no other shoulder pathology and were not participants in any other upper limb rehabilitation. All patients complained on severe shoulder pain and severely limited active range of motion with inability to actively elevate the arm to the horizontal. They all had full passive range of motion.

The diagnosis of a Massive irreparable rotator cuff tear was confirmed by diagnostic ultrasound scan. The shoulder function was evaluated using the Constant Score. Patients’ active shoulder ranges of motion were recorded and video-recorded as well. Each participant was taught the initial 6-week of self Deltoid muscle exercise, executed in supine, at least three times a day. They were instructed that when they felt better control on their active shoulder movements to gradually recline up the head of the bed and continue with the same simple exercise. They were reviewed at 6 weeks re-assessed and re-taught the same exercise, with a 2kg weight in their hand. At the 12th week they were reassessed using the constant score, and their active range of motion was video recorded again.

Results: 90% of the participants expressed a significant improvement in their upper limb function already after 6 weeks of treatment. All components of the Constant score (beside the strength) have improved. 90% reported less pain and found general activities of daily living easier to execute and a diminished level of muscle fatigue. 10% of the patients were able to establish a recording of > 1.26kg on the myometer in 90 degrees of abduction. 10% failed to report any benefit.

Discussion and Conclusion: Anterior deltoid strengthening exercises in the supine position for re-education of the anterior deltoid seem to have a significant beneficial effect for restoration of shoulder function and pain relief in the majority of patients with Massive irreparable degenerative rotator cuff tears. Using this simple non-invasive rehabilitation technique helps to re-educate the anterior deltoid to compensate for the absent rotator cuff and restore shoulder function.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 166 - 166
1 Apr 2005
Bhargava A Venkateswaran B Copeland S Even T Levy O
Full Access

The Constant-Murley score has gained wide acceptance for evaluation of shoulder function. The strength component of the Constant score accounts for 25 out of 100 points. It has been criticized for lack of consistency in defined measurement method.

The aim of this study was to evaluate the effect of various variables on the strength component measurement of the Constant score.

Material & Methods We conducted a series of experiments using a digital force gauge (EZ force). We evaluated the effect of strength measurements with 1) patient in sitting & standing positions 2) strength gauge fixed to an immobile platform or hanging free fixed to the floor by the examiners foot 3) patient’s arm in 45 degrees and 90 degrees of abduction 4) plane of elevation in frontal or scapular plane and 5) patient making a fist or keeping the palm open during the test. These experiments were done in groups of 20 patients. We have compared as well this device and the Isobex Myometer.

Results No statistical differences were found between individual measurements with regard to patient’s position (standing-sitting), device setting (Fixed –Hanging), position of the arm in varying degrees of abduction or the plane of elevation. Strength assessment obtained when patient made a fist compared to open palm was found to be higher (p=0.006). The measurements showed good intra-observer reliability.

The readings of the EZ force and the Isobex myometer were comparable.

Conclusions It seems that the shoulder strength measurements as part of the Constant functional score may be performed with the patient sitting or standing, with the arm at varying degrees of abduction and in different planes of elevation without causing any significant deviation in the measurement.

No influence was found as well to the device being either fixed to an immobile platform or fixed to the floor by the examiner’s foot. These make these measurements easy to perform and reproducible using the newly designed digital force gauge (EZ force).


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 170 - 170
1 Apr 2005
Venkateswaran B Zaman T Even T Kapila A Bargava A Copeland S Levy O
Full Access

Aim: Despite many studies the implications of perfusion and blood flow abnormalities in the rotator cuff (RC) in vivo are not clearly understood. Laser Doppler Flowmetry (LDF) is an established technique for the measurement of perfusion in tissue, which has been applied in animal and human studies. This study aims to evaluate Laser Doppler Flowmetry (LDF) as a technique for the assessment of blood flow in the normal and diseased RC.

Methods: With Ethics committee approval and informed consent patients undergoing arthroscopy for impingement or cuff tear (diseased cuff) and instability (normal cuff – BO) were recruited. Following diagnostic arthroscopy and bursoscopy measurements of the LDF in the RC tear were made at 6 points. Five of these were in the cuff over a 4 cm. 2 are from the insertion at the greater tuberosity and one in the deep surface.

Diseased RC were sub grouped into mild (B1), moderate (B2) and severe (*B3 – cuff tear) impingement grades (Copeland – Levy Classification). The arthroscopy, grading, and probe placement were made by the senior authors. LDF flux (LDFf) was recorded over 30 seconds at each measurement point. The mean of these readings was then calculated (LDF flux – an arbitrary unit of measurement of the perfusion).

Results: 35 patients were recruited. 210 measurements were recorded, in 6 anatomical locations. The mean LDFf was 34.1 in diseased RC and 55.3 in normal RC (p=0.0002). The mean LDFf was 52.2 in severe (RC tear) impingement and 30.3 in mild and moderate impingement’s (p< 0.0001).

The LDFf was lowest in the moderate grade with a significant increase at the edges of a cuff tear.

Conclusion: Preliminary recording of LDFf show changes are in keeping with current knowledge of the pathology. LDFf decreases with advancing impingement. There is an increase in LDFf at the edges of RC tears. This might reflect a reparative response.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 205 - 205
1 Mar 2004
Levy O
Full Access

Thermal capsular shrinkage presents the prospect of reducing redundant capsule, and therefore may be a suitable method of treating capsular-type instability. A prospective study of fifty-four consecutive patients (58 shoulders) treated exclusively with radiofrequency capsular shrinkage for atraumatic instability. The mean Rowe score improved from 33.1 to 74.1 points at followup of up to 48 months. Twenty of the fifty-eight shoulders had recurrence instability. Recurrent instability was related to the type of instability: 76.9% for voluntary instability, 30.3% for involuntary instability and none of 12 shoulders for instability/impingement pain. Recurrence was related as well to previous instability surgery (70%). The outcome was not related to the direction of instability, type of radiofrequency probe used, age of patient or ligamentous laxity. Twenty-two (57.9%) of thirty-eight patients returned to their pre-instability level of sporting activity. By using repeated RF treatments for the failed thermal shrinkage cases the failure rate was reduced from (20/58) 34.5% to (13/58) 22.4% and cumulative changes were seen on electron microscopy. These results are comparable to some of the results for open inferior capsular shift for patients with multidirectional instability with substantial less morbidity. The application of the minimal effective energy is controlled according to the tissue response without any charring or burning effect to the tissue. No scar was seen in repeated arthroscopies, or in electron microscopy studies. Thermal shrinkage does not negatively affect a later open stabilisation, but rather may provide better conditions for secure open surgery. We have found significant improvement in proprioception following thermal shrinkage treatment. We believe that by re-tensioning the proprioceptors they begin to fire off at lesser degrees of movement, and that there is a greater dynamic muscular contribution to shoulder stability. When using the correct technique for the right indications, Radiofrequency thermal shrinkage is a viable alternative to open inferior capsular shift in patients with capsular type of instability.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 100 - 100
1 Jan 2004
Brownlow H Freemont A Even T Copeland S Levy O
Full Access

The coraco-acromial ligament (CAL) is partially resected during a subacromial decompression. Clinical studies have reported the regeneration of a structure which appears to be a new CAL. Histological studies of regenerated CAL have demonstrated an abundance of relatively acellular collagen fibrils orientated in the line of a ligament and mechanical testing of the regenerated tissue has properties similar to those of normal CAL. However it is still not clear whether this structure represents scar tissue or truly reformed ligament. Defining the major collagen constituent of this regenerated tissue would allow the distinction between ligament and scar tissue. Therefore the aim of this study was to examine the level of expression of types I and III collagen in regenerated coraco-acromial ligaments (CAL) in humans.

Samples of regenerated CAL were obtained during open surgery for repair of small rotator cuff tears at an average of 24 months (range 14 to 52) after arthroscopic subacromial decompression from 4 men and 3 women with an average age of 58 years (range 44 to 68). A standard protocol radio-active in-situ immunolocalisation technique was used to quantify the ratios of mRNA collagen I to collagen III in the samples.

The results demonstrated that the average ratio of collagen I to collagen III was 6.5. This ratio is similar to the value for normal hip capsule (5–6:1) and human posterior cruciate ligament (8:1).

We conclude that the reformed CALs are ligamentous structures, not scar tissue, and therefore represent truly regenerated ligaments.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 98 - 98
1 Jan 2004
Matthews T Levy O
Full Access

Arthroscopic shoulder surgery is evolving rapidly and several methods of stabilisation have been described. We present a simple new technique which addresses both the Bankart lesion and the capsular stretching together with the short-term results.

The technique can be performed using just one anterior working portal and one posterior viewing portal. The labrum and capsule are elevated from the anterior glenoid neck by sharp dissection. One suture anchor is placed at the half past four position. One suture limb is passed under the labrum at 6 o’clock, the other limb is passed under the labrum at 2 o’clock and the two ends are tied. This has a purse string effect, tightening the capsule in only the superior/inferior plane, which also creates a bumper of labrum at the anterior glenoid rim.

This technique was used in 35 patients (36 shoulders) with recurrent antero-inferior instability due to a traumatic Bankart lesion. The patient group included 33 men and 2 women with mean age 25 years (16–49). They had sustained an average of 5 dislocations per shoulder (1 to 11). The cohort included 4 professional and 6 semi-professional sportsmen all of whom were involved in collision or overhead sports. All the patients were assessed by an independent investigator at an average of 14 months (6–48) post surgery.

Only one patient developed recurrent instability. This occurred without sustaining trauma. The average postoperative Rowe score was 93 (55–100), Walch-Duplay score was 93 (70–100), and Constant score was 97 (77–100). 65% of patients returned to the same level of sports and all the professional athletes were able to resume full activities.

In conclusion, this technique is simple in concept, straightforward to perform, and demonstrates excellent short-term results.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 98 - 98
1 Jan 2004
Rath E Even T Brownlow H Copeland S Levy O
Full Access

Use of shoulder manipulation in the treatment of frozen shoulder (FS) remains controversial. One of the purported risks associated with the procedure is the development of a rotator cuff tear. However the incidence of iatrogenic rotator cuff tears has not been reported. The purpose of the study was to assess the effect of manipulation of the shoulder on the integrity of the rotator cuff.

In a prospective study 20 consecutive patients (21 shoulders) with FS underwent manipulation of the shoulder under anaesthesia (MUA). The average duration of symptoms was 7.3 months (4–18 months). Patients were assessed pre and post manipulation using the Constant score. An ultrasound scan of the rotator cuff was performed before and at 3 weeks after manipulation.

In all patients, pre and post manipulation ultrasound scans showed the rotator cuff to be intact. At 12 weeks after manipulation all patients indicated that they had none or only occasional pain. The mean improvement in motion was 83 degrees (range, 20 – 100°) for flexion, 95 degrees (range, 20 – 120°) for abduction, 58 degrees (range, 0 – 80°) for external rotation and 3 levels of internal rotation (range 3–5 levels). These gains in motion were all significant (p < 0.01). No fractures, dislocations or nerve palsies were observed.

In conclusion manipulation under anaesthesia for treatment of frozen shoulder resulted in significant improvements in shoulder function and pain relief as early as 3 weeks after surgery and was not associated with rotator cuff tears. When performed carefully this procedure is safe and leads to early improvements in pain relief, range of movement and shoulder function.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 99 - 99
1 Jan 2004
Funk L Koury E Levy O Copeland S
Full Access

Avascular necrosis (AVN) of the humeral head is an extremely disabling condition (Gerber et al, JSES 1998. 7(6):586–90). The results of stemmed arthroplasty for this condition are good, with Hattrup and Cofield reporting 79% subjective improvement at nine years (JSES 2000;9:177–82). This study reports the outcomes of surface replacement shoulder arthroplasties for AVN over a 16 year period. Between 1986 and 2001 twenty-seven arthroplasties were performed in patients with advanced avascular necrosis of the humeral head. All patients had secondary degenerative changes. AVN was secondary to corticosteriods and trauma in most cases.

The mean age of the patients was 60 years (range 35 to 86). These included 16 hemiarthroplasties and 7 total shoulder arthroplasties. All prostheses were of the Copeland Surface Replacement Arthroplasty (CSRA) type.

The average follow up period was 6 years (range 1 to 13). The average preoperative Constant score was 17. This improved to 74 at follow-up. Forward flexion improved from 63 degrees preoperatively to 133 degrees at follow-up. Abduction improved from 49 degrees to 118 degrees. External rotation improved from −3 degrees to 61 degrees. Pain scores improved from 0 to 11.7, using a 15 point visual analogue scale. 81% of patients had slight and no difficulty performing their routine activities of daily living. The remaining 19% still had some difficulty with routine activities. Four of the patients performed regular overhead activity and recorded some difficulty in doing this, whereas they had great difficulty pre-operatively. There were no cases of loosening. No difference was seen in any of the results between the hemi-arthroplasty and total shoulder replacement patients.

Surface replacement arthroplasty is a suitable procedure for degenerative disease secondary to AVN of the humeral head, with results similar to stemmed prostheses. It has the advantage of preserving bone stock.