We aimed to determine hip-related quality of life and clinical findings following treatment for neonatal hip instability (NHI) compared with age- and sex-matched controls. We hypothesized that NHI would predispose to hip discomfort in long-term follow-up. We invited those born between 1995 and 2001 who were treated for NHI at our hospital to participate in this population-based study. We included those that had Von Rosen-like splinting treatment started before one month of age. A total of 96 patients treated for NHI (75.6 %) were enrolled. A further 94 age- and sex-matched controls were also recruited. The Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire was completed separately for both hips, and a physical examination was performed.Aims
Methods
Previous studies from single centres or single-surgeon
series report good early and mid-term results for high tibial osteotomy
(HTO) in the treatment of osteoarthritis of the knee. However, the
survivorship of HTO at a national level is unknown. This registry-based
study included 3195 high HTOs performed between 1987 and 2008. Kaplan-Meier analysis
revealed an overall survivorship of 89% (95% confidence interval
(CI) 88 to 90) at five years and 73% (95% CI 72 to 75) at ten years,
when conversion to total knee replacement was taken as the endpoint.
Females and patients aged >
50 years had worse survivorship than
males or patients aged ≤ 50 years (hazard ratio (HR) 1.26 (95% CI
1.11 to 1.43) and HR 1.41 (95% CI 1.23 to 1.64), respectively).
The survivorship of HTOs performed between 1998 to 2008 was worse
than for those performed between 1987 and 1997.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
Study Design: A prospective, randomized clinical trial.
Since the 1970s Swanson implant arthroplasty has become a treatment of choice in metacarpohalangeal (MCP) joint arthroplasty in destructed MCP joints of rheumatoid patients. Sutter (Avanta) implant is also composed of silicone but the centre of rotation is more anatomical, and volar to improve extension moment. Clinical results about these implants have been similar but fracture rates of Sutter implant have been reported to be high. Reason for osteolysis is inflammation reaction to silicone particles released from prostheses due to movement of prosthesis in bone or implant fractures. Reports about osteolysis around Swanson implants present variable result. There is not grading of osteolysis in the literature before and we created a new radiographic grading for osteolysis around silicone MCP implants. Grading is based on involvement of cortical bone: Grade I: Osteolysis varying from a single clear line adjacent to the stem of the prosthesis to a larger, clear area which did not involve the bone cortex; Grade II: Osteolysis affecting the bone cortex to a maximum of one half of the thickness of the cortex; Grade III: Osteolysis affecting the cortex to more than one half of its thickness but not perforating the cortex; Grade IV: Osteolysis perforating the cortex. In this study we compare the incidence of radiographic osteolysis following insertion of 89 Swanson and 126 Sutter MCP implants in rheumatoid arthritis patients. Before surgery hands were randomised one by one to Swanson and Sutter implant groups. The mean follow-up time in the two groups of patients was 57 (40–80) and 55 (36–79) months, respectively. A total of 45 (60%) metacarpal and 40 (53%) proximal phalangeal bones showed no osteolytic changes in the Swanson group. In the Sutter group numbers were 20 (21%) and 26 (27%). In the Swanson group, there was less cortical osteolysis and there were 4 (5%) perforations of a metacarpal and no perforations of a proximal phalanx. In the Sutter group, there were 9 (9%) perforations in a metacarpal and 5 (5%) in a proximal phalanx. (p<
0.001). To create a single independent observation of osteolysis for a hand, the worst osteolysis of a metacarpal or proximal phalanx was recorded. There was only one (5%) perforation in the Swanson group, while there were 8 (30%) perforations in the Sutter group (p=0.011). In all grades of our classification, osteolysis was more frequent in the Sutter than in the Swanson group.