This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test.Aims
Methods
Patients with proximal femoral fractures (PFFs) are often multimorbid, thus unplanned readmissions following surgery are common. We therefore aimed to analyze 30-day and one-year readmission rates, reasons for, and factors associated with, readmission risk in a cohort of patients with surgically treated PFFs across Austria. Data from 11,270 patients with PFFs, treated surgically (osteosyntheses, n = 6,435; endoprostheses, n = 4,835) at Austrian hospitals within a one-year period (January to December 2021) was retrieved from the Leistungsorientierte Krankenanstaltenfinanzierung (Achievement-Oriented Hospital Financing). The 30-day and one-year readmission rates were reported. Readmission risk for any complication, as well as general medicine-, internal medicine-, and surgery/injury-associated complications, and factors associated with readmissions, were investigated.Aims
Methods
The aim of this study was to investigate the metabolomic profile of synovial fluid in periprosthetic joint infection (PJI) cases regarding a possible diagnostic approach. Also, further information about the metabolic composition of synovial fluid in PJI may point to future diagnostic and therapeutic approaches. Patients with a clinical suspicion of a prosthesis infection who underwent a joint puncture in our outpatient department or ward were included. After sample preparation, the nuclear magnetic resonance (NMR) experiments were performed at 310 K on an AVANCE™ NeoBruker Ultrashield 600 MHz spectrometer. Bruker Topspin version 4.0.2 was used for NMR data acquisition. The spectra for all samples were automatically processed (exponential line broadening of 0.3 Hz), phased, and referenced using TSP at 0.0 ppm. In total, 37 metabolites were analysed using a volume of 200 µl per synovial sample. The PJI and aseptic cases were assigned according to the EBJIS criteria.Aim
Method
The aim of this prospective study was to assess the long-term clinical, radiological, functional, and quality of life (QoL)-related outcome of patients treated with the synthetic Ligament Advanced Reinforcement System (LARS) device for anterior cruciate ligament (ACL) rupture. A total of 41 patients who underwent ACL reconstruction with the LARS device (mean age 39.8 years (SD 12.1 ); 32% females (n = 13)) were prospectively included between August 2001 and March 2005. MRI scans and radiographs were performed at a median follow-up of 2.0 years (interquartile range (IQR) 1.3 to 3.0; n = 40) and 12.8 years (IQR 12.1 to 13.8; n = 22). Functional and QoL-related outcome was assessed in 29 patients at a median follow-up of 12.8 years (IQR 12.0 to 14.0) and clinically reconfirmed at latest median follow-up of 16.5 years (IQR 15.5 to 17.9). International Knee Documentation Committee (IKDC) and Tegner scores were obtained pre- and postoperatively, and Lysholm score postoperatively only. At latest follow-up, range of motion, knee stability tests, 36-Item Short Form Health Survey (SF-36), and IKDC scores were ascertained. Complications and reoperations during follow-up were documented.Aims
Methods
To improve the challenging treatment of periprosthetic joint infections (PJI), researchers are constantly developing new handling methods and strategies. In patients with PJI after total knee arthroplasty (TKA) and severe local or systemic comorbidities, a two-stage exchange using a temporary antibiotic loaded PMMA-spacer is considered gold standard. This method has undisputed advantages, however, the increased risk of biofilm formation on the spacer surface, bone defects and soft tissue contractions after a six-week spacer interval are severe limitations. Our hypothesis is that a vacuum sealed foam in combination with constant instillation of an antiseptic fluid can address these drawbacks due to a significantly reduced spacer interval. A pilot study was conducted in five PJI cases after TKA with severe comorbidities and/or multiple previous operations to evaluate the feasibility and safety of the proposed method. In the first step, surgical treatment included the explantation of the prosthesis, debridement, and the implantation of the VeraFlo-Dressing foam. The foam is connected to the VAC-Instill-Device via an inflow and an outflow tube. The surgical site is sealed airtight with the VAC-film. During the next 5 days, an antiseptic fluid (Lavasorb® or Taurolidine®) is instilled in a 30-minute interval using the VAC-Instill-Device. The limb is immobilized (no flexion in the knee joint, no weight bearing) for five days. Following that, the second operation is performed in which the VAC-VeraFloTM-Therapy System is explanted and the revision TKA is implanted after debridement of the joint.Aim
Method
The aims of the study were to analyze differences in surgical and oncological outcomes, as well as quality of life (QoL) and function in patients with ankle sarcomas undergoing three forms of surgical treatment, minor or major limb salvage surgery (LSS), or amputation. A total of 69 patients with ankle sarcomas, treated between 1981 and 2017 at two tumour centres, were retrospectively reviewed (mean age at surgery: 46.3 years (SD 22.0); 31 females (45%)). Among these 69 patients 25 were analyzed prospectively (mean age at latest follow-up: 61.2 years (SD 20.7); 11 females (44%)), and assessed for mobility using the Prosthetic Limb Users Survey of Mobility (PLUS-M; for amputees only), the Toronto Extremity Salvage Score (TESS), and the University of California, Los Angeles (UCLA) Activity Score. Individual QoL was evaluated in these 25 patients using the five-level EuroQol five-dimension (EQ-5D-5L) and Fragebogen zur Lebenszufriedenheit/Questions on Life Satisfaction (FLZ).Aims
Methods
Our aim was to develop and validate nomograms that would predict the cumulative incidence of sarcoma-specific death (CISSD) and disease progression (CIDP) in patients with localized high-grade primary central and dedifferentiated chondrosarcoma. The study population consisted of 391 patients from two international sarcoma centres (development cohort) who had undergone definitive surgery for a localized high-grade (histological grade II or III) conventional primary central chondrosarcoma or dedifferentiated chondrosarcoma. Disease progression captured the first event of either metastasis or local recurrence. An independent cohort of 221 patients from three additional hospitals was used for external validation. Two nomograms were internally and externally validated for discrimination (c-index) and calibration plot.Aims
Methods
This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton. A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs.Aims
Methods
In the diagnosis of prosthetic joint infection (PJI), many biomarkers have shown a sound performance in terms of accuracy, sensitivity and specificity. In this study we aimed to test the frequently used serum biomarkers C-reactive Protein (CRP), Fibrinogen, Leukocytes, Interleukin-6 (IL-6), Interferon alpha (IF-alpha) and Procalcitonin (PCT) regarding these qualities. Following that, the optimal multi-biomarker combination was calculated to further improve the diagnostic performance. 124 knee or hip revision arthroplasty procedures were prospectively investigated focusing on preoperative serum blood levels of CRP, Fibrinogen, Leukocytes, IL-6, IF-alpha and PCT. The presence of PJI was determined by a blinded researcher. Logistic regression with lasso-regularization was used for the biomarkers and all their ratios. Following cross-validation on a training sample set to get optimal performance estimates, we performed the final model on a test set (25% of all samples).Aim
Method
Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for extended bone defects. The currently published mid-term results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological mid-term outcome of metaphyseal sleeve fixation in septic RTKA surgery (minimum follow-up of 2 years). Between January 2005 and September 2015, 57 patients underwent septic RTKA surgery using metaphyseal sleeves. In 56 patients (98,2 %) who underwent a total of 69 two stage revision procedures, clinical and radiological follow-up examinations were conducted. One patient (1,8 %) was lost to follow-up. The examinations included the American Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the SF-36 Health survey as well as radiographic measurement to determine if successful osseointegration had been achieved.Aim
Method
One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of metaphyseal sleeve fixation in septic two-stage knee revision surgery. Clinical and radiological follow-up examinations were performed in 49 patients (25 male and 24 female). All patients were treated with a two-stage procedure, using a temporary non-articulating bone cement spacer. The spacer was explanted after a median of 12 weeks (SD 5, min. 1 – max. 31) and reimplantation was performed, using metaphyseal sleeves in combination with stem fixation. Bone defects were classified on preoperative radiographs using the Anderson Orthopaedic Research Institute (AORI) classification. During follow-up postoperative range of motion (ROM) was measured and radiographs were performed to analyse: (i) osseointegration (radiolucent lines and spot welds), (ii) leg alignment, (iii) patella tilt and shift.Aim
Method
The use of antibiotic-loaded cement has become a well-accepted method to develop high local antibiotic concentrations in orthopedic surgery. A new surgical technique has been established in our department in order to further increase the local antibiotic concentration, when implanting a prosthesis during revision surgery. By additional superficial vancomycin coating of the bone cement, high local antibiotic concentrations are generated. They should reach inhibiting and bactericidal concentrations of the respective pathogen during the first days after surgery. The aim of this study was to state the safety of this method by analyzing postoperative serum and drain vancomycin concentrations. Attention was focused on possible systemic side effects. To determine nephrotoxicity, creatinine levels were also measured. In total 32 revision operations (hip n=10, knee n=22) with additional superficial vancomycin coating were performed between 05/2013 and 04/2015. Procedures with removal of the prosthesis following temporary spacer implantation were excluded. In nine cases a one-stage procedure was performed, while in the others an arthroplasty or arthrodesis was performed after temporary spacer explantation. Vancomycin powder (2 grams) was added superficially to the surface of the bone cement and pressed onto manually before curing. Postoperative Vancomycin levels were measured in serum and the drain on day 1 to 5 or until the drain has been removed. In total 90 blood serum samples and 100 drain fluid samples were obtained. The highest median vancomycin level from the drain was documented on postoperative day 1 with a value of 555.3 μg/mL (range 66.1 – 1081.8), continually decreasing until postoperative day 4. The highest value was documented on the second postoperative day with 2170.0 μg/mL. On the first postoperative day, a median serum vancomycin level of 3.35 μg/mL was present (range <2.0 – 8.5), while from postoperative day 2 to 5 a median level less than 2.0 μg/mL (range <2.0 – 7.2) was documented. Anaphylactic reaction, red man syndrome or fever and chills were not observed after the surgical procedure. Furthermore, no subjective hearing loss was reported. Only in one case, a creatinine increase of 0.5 mg/dL from baseline value was detected. In this case the patient suffered preoperatively from a chronic kidney insufficiency. In total two reinfections occurred, one after explanting a spacer with subsequent hip total endoprosthesis, the other one after a one-stage hip revision. Superficial Vancomycin Coating of bone cement in orthopedic revision surgery represents a safe method to increase local inhibiting vancomycin concentrations.
In two-stage revision surgery of infected joint prosthesis, temporary bone cement spacers have been used for several years. By adding antibiotics to the cement, high local antibiotic concentrations that exceed the minimum inhibiting and bactericidal concentration of the respective pathogen during the first days after surgery, are achieved. Currently, aminoglycosides (e.g. gentamicin and tobramycin), as well as glycopetides (e.g vancomycin) are used as antibiotic agents and mixed into the acrylic cement. In order to increase the quantity of active antibiotic substances, we established a novel surgical technique of additional superficial vancomycin coating (SVC) of temporary bone cement spacer. The aim of this study was to analyze the safety of this method by measuring postoperative joint and serum vancomycin concentrations, as well as the creatinine levels. We reviewed prospectively collected data on all patients, which were treated by explanting the prosthetic components, following temporary spacer implantation and SVC between 05/2013 and 04/2015 at the Department of Orthopedic Surgery, Medical University of Graz. In total 13 patients were treated by addition SVC during the study period. Before hardening, vancomycin powder (2 grams) was pressed manually onto the surface of the bone cement. Vancomycin levels were obtained from drains and blood samples on postoperative days 1 to 5. Forty-six blood serum samples and 52 drain fluid samples were available for further On postoperative day one to five, a median serum vancomycin level of < 2.0 μg/mL was present (range <2.0 – 3.9). The highest median vancomycin level from the drain was documented on postoperative day 1 with a value of 388.0 μg/mL (range 44.4–1650.0), continually decreasing until postoperative day 4. After SVC, neither an anaphylactic reaction nor side effects such as a red man syndrome, fever and chills were observed. Furthermore, no patient complained about subjective hearing loss. No serum creatinine increase of 0.5 mg/dL from creatinine baseline value or a ≥50% increase from baseline was detected. After a median of 64 days (range 18–82), the temporary cement spacer was explanted followed by prosthesis implantation. During this time no reinfection occurred. One patient suffered from a dislocation of the spacer with a distal femur fracture and was therefore re-operated after 18 days. Powdered vancomycin as an additional superficial coating of bone cement spacer results in much higher local antibiotic concentrations than in conventional spacers. The newly introduced method is feasible, safe and promising to enhance local inhibiting concentrations of vancomycin.
The aims of this study were to evaluate the incidence
of local argyria in patients with silver-coated megaprostheses and
to identify a possible association between argyria and elevated
levels of silver both locally and in the blood. Between 2004 and
2011, 32 megaprostheses with silver coatings were implanted in 20
female and 12 male patients following revision arthroplasty for
infection or resection of a malignant tumour, and the levels of
silver locally in drains and seromas and in the blood were determined.
The mean age of the patients was 46 years (10 to 81); one patient
died in the immediate post-operative period and was excluded. Seven patients (23%) developed local argyria after a median of
25.7 months (interquartile range 2 to 44.5). Patients with and without
local argyria had comparable levels of silver in the blood and aspiration
fluids. The length of the implant did not influence the development
of local argyria. Patients with clinical evidence of local argyria
had no neurological symptoms and no evidence of renal or hepatic
failure. Thus, we conclude that the short-term surveillance of blood
silver levels in these patients is not required. Cite this article:
Matrix metalloproteinases (MMPs), responsible
for extracellular matrix remodelling and angiogenesis, might play
a major role in the response of the growth plate to detrimental
loads that lead to overuse injuries in young athletes. In order
to test this hypothesis, human growth plate chondrocytes were subjected
to mechanical forces equal to either physiological loads, near detrimental
or detrimental loads for two hours. In addition, these cells were
exposed to physiological loads for up to 24 hours. Changes in the
expression of MMPs -2, -3 and -13 were investigated. We found that expression of MMPs in cultured human growth plate
chondrocytes increases in a linear manner with increased duration
and intensity of loading. We also showed for the first time that
physiological loads have the same effect on growth plate chondrocytes
over a long period of time as detrimental loads applied for a short
period. These findings confirm the involvement of MMPs in overuse injuries
in children. We suggest that training programmes for immature athletes
should be reconsidered in order to avoid detrimental stresses and
over-expression of MMPs in the growth plate, and especially to avoid
physiological loads becoming detrimental. Cite this article:
Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted total shoulder prosthesis Delta in the elderly. However, despite the generally high success rate and satisfying clinical results of inverted total shoulder arthroplasty, this treatment option has potential complications. Therefore, the objective of this study was a prospective evaluation of the clinical and radiological outcome after a minimum of 2 years follow-up of patients undergoing inverted shoulder replacement with or without prior rotator cuff repair. Sixty-eight shoulders in 66 patients (36 women and 30 men) operated between February 2002 and June 2007 with a mean age of 66 years (ranging from 53 to 84 years) were first assessed preoperatively and then at minimum 2 years follow-up, using the Constant score for pain, Constant Shoulder Score, Oxford Shoulder Score, UCLA Shoulder rating scale, DASH Score, Rowe Score for Instability and Oxford Instability Score. 29 patients (Group A) had undergone previous shoulder arthroscopy for cuff tear reconstruction at a mean of 29 months (range 12 to 48 months) before surgery and 39 patients (Group B) underwent primary implantation of an inverted total shoulder prosthesis Delta. Any complications in both groups were assessed according to Goslings and Gouma.Introduction
Patients and Methods
The rising incidence of atraumatic fractures in patients either with Ewing's sarcoma or osteosarcoma years after chemotherapy revealed a growing population of childhood cancer survivors with a decreased bone mineral density (BMD) possibly due to a long-term effect of the chemotherapy. Therefore we started to screen our patients below 50y of age who were treated for bone malignancies between 1994 and 2009. The first series of measurements included 15 patients – eight Ewing's sarcoma, three female and five male, with a mean age of 18y (±13SD), and seven osteosarcoma, two female and five male, with a mean age of 19y(±9SD). We screened the patients for deficits in their bone status using DEXA (dual-energy-x-ray-absorptiometry) to gain the T-and Z-Scores of the proximal femur and the lumbal spine. Additionally we took blood samples for endocrinological analysis and utilised a questionnaire to scan the patient's liefestyle. The mean time between diagnosis and investigation was 95months (±79SD) in Ewing's sarcoma and 105months (±54 SD) in osteosarcoma. The results of the age and gender matched lumbal measurement (Z-Score) of the Ewing's sarcoma patients showed a reduction of the BMD in six cases (6/8), including three times osteopenia (3/8) and two times osteoporosis (2/8). The osteosarcoma patients presented a BMD-decline in four cases (4/7) with two times osteopenia (2/7) and one osteoporosis (1/7). In the proximal femur six Ewing's sarcoma (6/8) and six osteosarcoma patients (6/7) showed a BMD-decrease including three osteopenic (3/8) and one osteoporotic (1/8) Ewing's sarcoma and four osteopenic osteosarcoma (4/7). We found two cases of pathologic fractures (2/15), one Ewing's sarcoma 29 months after diagnosis with a fracture of the distal femur and the proximal Tibia (1/8) and one osteosarcoma with a fractured distal femur after 72 months (1/7). As presented in our case series osteoporosis after chemotherapy is an underestimated long-term effect of the chemotherapeutic treatment. In our series BMD-reduction seems to be independent of tumour-type and chemotherapeutic agent like MTX.
Accurate and reliable patient information plays a crucial role in the multidisciplinary treatment of malignancies helping to ensure compliance of the patients and their relatives with often long-lasting and stressful treatment. The English version of the online encyclopaedia Wikipedia has been recently reported to be the prominent source of online health information. However, there is little information concerning the quality of information found in Wikipedia. We therefore created a questionnaire concerning of 20 questions asking for scope, completeness and accuracy of information found on osteosarcoma. Three independent observers tested the English version of Wikipedia as well as the patient version and the health professional version of the website of the National Cancer Institute. Answers (scores 0-3) were verified with authoritative resources and international guidelines.Aim
Method
All four patients treated with en bloc resection (primary or secondary) had no recurrence but in two out of that cases a re-operation was necessary because of non union. At a mean follow up from 27 months (4–95) there were no recurrences or metastases at all The flexion/extension of the wrist in currettaged radius was 60° and 80° compared with 38° and 68° in reconstructed radius. The pronation/suppination was 90°/90° in the currettaged ones versus 77°/77° in the allograft replaced ones. The functional outcome evaluated with Mayo Wrist Score and DASH score showed an exellent outcome for both groups (84/7,7 Allograft <
->
85/10 Currettage)