Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the long-term follow-up of single and double row fixation in arthroscopic cuff repair. The purpose of this study was to compare the long-term functional outcomes of single-row and double-row suture techniques for repair of the rotator cuff 10-years post-operatively. Ninety patients undergoing arthroscopic rotator cuff repair were randomized to receive either single-row or double-row repair. The primary objective was to compare the Western Ontario Rotator Cuff Index (WORC) score 10-years post-operatively. Secondary objectives included comparison of the Constant, and American Shoulder and Elbow Surgeons (ASES) scores and supraspinatus strength between groups. Out of 90 patients originally randomized, 57 returned for the long-term 10-year follow-up. Baseline demographic data did not differ between groups. The WORC score was not significantly different between groups at long-term follow-up (p=0.13). No statistical differences were observed between groups for the Constant (p=0.51), ASES (p=0.48) scores, or strength scores (p=0.93). A significant improvement was observed between pre-operative and the final 10-year follow-up. There were no differences observed in all outcomes between two and 10-years post-operatively. No statistically significant differences in functional or quality of life outcomes were identified between single-row and double-row fixation techniques at long-term follow-up.
When compared to magnetic resonance imaging (MRI), ultrasound (US) performed by experienced users is an inexpensive tool that has good sensitivity and specificity for diagnosing rotator cuff (RC) tears. However, many practitioners are now utilizing in-office US with little to no formal training as an adjunct to clinical evaluation in the management of RC pathology. The purpose of our study was to determine if US without formal training is effective in managing patients with a suspected RC tear. This was a single centre prospective observational study. Five fellowship-trained surgeons each examined 50 participants referred for a suspected RC tear (n= 250). Patients were screened prior to the consultation and were included if ≥ 40 years old, had an MRI of their affected shoulder, had failed conservative treatment of at least 6 months, and had ongoing pain and disability. Patients were excluded if they had glenohumeral instability, evidence of major joint trauma, or osteonecrosis. After routine clinical exam, surgeons recorded their treatment plan (“No Surgery”, “Uncertain”, or “Surgery”). Surgeons then performed an in-office diagnostic US followed by an MRI and documented their treatment plan after each imaging study. Interrater reliability was analyzed using a kappa statistic to compare clinical to ultrasound findings and ultrasound findings to MRI, normal and abnormal categorization of biceps, supraspinatus, and subscapularis. Following clinical assessment, the treatment plan was recorded as “No Surgery” in 90 (36%), “Uncertain” in 96 (39%) of cases, “Surgery” in 61 (25%) cases, and incomplete in 3 (2%). In-office US allowed resolution of 68 (71%) of uncertain cases with 227 (88%) of patients having a definitive treatment plan. No patients in the “No Surgery” group had a change in treatment plan. After MRI, 16 (6%) patients in the “No Surgery” crossed-over to the “Surgery” group after identification of full-thickness tears, larger than expected tears or alternate pathology (e.g., labral tear). The combination of clinical examination and in-office US may be an effective method in the initial management of patients with suspected rotator cuff pathology. Using this method, a definitive diagnosis and treatment plan was established in 88% of patients with the remaining 12% requiring an MRI. A small percentage (6%) of patients with larger than expected full-thickness rotator cuff tears and/or alternate glenohumeral pathology (e.g., labral tear) would be missed at initial evaluation.
Musculoskeletal ultrasound (MSK-US) can have many uses for orthopaedic surgeons, such as assisting in clinical diagnosis for muscle, tendon and ligament injuries, providing direct guidance for joint injections, or assessing the adequacy of a reduction in the emergency department. However, proficiency in sonography is not a requirement for Royal College certification, and orthopaedic trainees are rarely exposed to this modality. The purpose of this project was to assess the usefulness in clinical education of a newly implemented MSK-US course in an orthopaedic surgery program. A MSK-US course for orthopaedic surgery residents was developed by an interdisciplinary team involving a paediatric orthopaedic surgeon, an emergency physician with a fellowship in point-of-care ultrasonography, and an orthopaedic surgery resident. Online videos were created to be viewed by residents prior to a half-day long practical course. The online portion covered the basics of ultrasonography, as well as the normal and abnormal appearance of musculoskeletal structures, while the practical portion applied those principles to the examination, injection, and aspiration of joints, and ultrasound-guided fracture reduction. An online survey covering the level of training of the resident and their previous use of ultrasound (total hours) was filled by the participants prior to the course. Resident's knowledge acquisition was measured with a written pre-course, same-day post-course and six-month follow-up tests. Residents were also scored on a practical shoulder examination immediately after the course and at six-month follow-up. An online survey was also sent to evaluate residents' satisfaction with different aspects of the course (NAS). Change in test scores were calculated using an ANOVA and a Wilcoxon signed-rank test. Ten orthopaedic surgery residents underwent the MSK-US curriculum. Pre-course interest to MSK-US was moderate (65%) and prior exposure was low (1.5 hours mean total experience). MSK-US has been previously mostly observed in the emergency department and sports orthopaedic clinic. Satisfaction with the online curriculum, hands-on practice session and general quality of the course were high (8.78, 8.70 and 8.60/10 respectively). Written test scores improved significantly from 50.7 ± 17% to 84 ± 10.7% immediately after the course (p < 0 .001) and suffered no significant drop at six months (score 75 ± 8.7%, p=0.303). Average post-course practical exam score was 78.8 ± 3.1% and decreased to 66.2 ± 11.3% at six months (p=0.012). Residents significantly improved their subjective comfort level with all aspects of ultrasound use at six months (p=0.007–0.018) but did not significantly increase clinical usage frequency. A MSK-US curriculum was successfully developed and implemented using an interdisciplinary approach. The course was rated high quality and succeeded in improving the residents' knowledge, skills, and comfort with MSK-US. This improvement was maintained at six months on the written test, but did not result in higher frequency of use by the residents.
The purpose of this study was to quantify tibial tunnel enlargement at 3-, 6- and 12-months post-anterior cruciate ligament reconstruction (ACLR), and evaluate the magnitude of tunnel widening with use of a Poly (L-lactic Acid) interference screw (PLLA (Bioscrew XtraLok, Conmed, New York)) compared to a Poly (L-lactic Acid) + tricalcium phosphate interference screw (PLLA+TCP (GENESYS Matryx screw comprised of microTCP and 96L/4D PLA, Conmed, New York)). This was a prospective randomized controlled trial with two parallel groups. Eighty unilateral ACL-deficient participants awaiting ACLR surgery were recruited between 2013 and 2017 from the clinic of a sole fellowship trained orthopaedic surgeon. Patients had to be skeletally mature and less than 45 years old, with no concomitant knee ligament injuries requiring surgery, chondromalacia, or previous history of ipsilateral knee joint pathology, surgery or trauma to the knee. Participants were randomized intra-operatively into either the PLLA or PLLA+TCP tibial interference screw fixation group. Study time points were pre-, 3-, 6-, and 12-months post ACLR. Participants underwent x-rays with a 25 mm calibration ball, IKDC knee assessment, and completed the ACL-Quality of Life score (ACL-QOL) at each visit. Measurement (mm) of the most proximal and distal extents as well as the widest point of the tibial tunnel were taken using efilm (IBM Watson Health) and were standardized relative to the calibration ball. A contrast inverter was used to determine clear borders based on contrast between normal and drilled bone. In addition, a subjective evaluation of the tunnel was conducted looking for bowing of the borders of the tunnel or change in tunnel shape, categorizing the tunnel as widened or not widened. Differences between groups at each time point were evaluated using independent t-tests corrected for multiple comparisons. Tunnel width was also compared as a percentage of actual screw size at 12-months post-operative. Categorical data were compared using Fisher's Exact Test. Forty participants were randomized to each group with mean age (SD) of 29.7 (7.6) and 29.8 (9.1), for PLLA and PLLA+TCP, respectively. There were no differences between groups in age, gender or ACL-QOL. There were no differences found between groups at any time point in either tunnel width measurements or tunnel width as a percentage of actual screw size. The greatest difference between groups was noted in the measurement of the widest point on lateral x-ray view with a mean difference of 11%. Based on subjective evaluation of tunnel shape, three participants had visible widening in the PLLA group, and two in the PLLA+TCP group (p=NS). No differences in tunnel widening were identified between ACL reconstruction patients using a PLLA interference screw compared to a PLLA+TCP screw for tibial fixation up to 12-months post-operative.
Recent literature has demonstrated that conventional arthroscopic techniques do not adequately visualise areas of predilection of pathology of the long head of biceps (LHB) tendon and are associated with a 30–50% rate of missed diagnoses. The aim of this study was to evaluate the safety, effectiveness and ease of performing biceps tenoscopy as a novel strategy for reducing the rate of missed diagnoses. Five forequarter amputation cadaver specimens were studied. The pressure in the anterior compartment was measured before and after surgical evaluation. Diagnostic glenohumeral arthroscopy was performed and the biceps tendon was tagged to mark the maximum length visualised by pulling the tendon into the joint. Biceps tenoscopy was performed using 3 different techniques (1. Flexible video-endoscopy, 2. Standard arthroscopy via Neviaser portal. 3. Standard arthroscope via antero-superior portal with retrograde instrumentation). Each was assessed for safety, ease of the procedure and whether the full length of the extra-articular part of the LHB tendon could be visualised. The t-test was used to compare the length of the LHB tendon visualised at standard glenohumeral arthroscopy vs that visualised at biceps tenoscopy. An open dissection was performed after the arthroscopic procedures to evaluate for an iatrogenic injury to local structures. Biceps tenoscopy allowed visualisation to the musculotendinous junction in all cases. The mean length of the tendon visualised was therefore significantly greater at biceps tenoscopy (104 mm) than at standard glenohumeral arthroscopy (33 mm) (mean difference 71 mm, p<0.0001). Biceps tenoscopy was safe with regards to compartment syndrome and there was no difference between pre- and post-operative pressure measurements (mean difference 0 mmHg, p=1). No iatrogenic injuries were identified at open dissection. Biceps tenoscopy allows excellent visualisation of the entire length of the LHB tendon and therefore has the potential to reduce the rate of missed diagnoses. This study did not demonstrate any risk of iatrogenic injury to important local structures or any risk of compartment syndrome. Clinical evaluation is required to further validate this technique.
The majority of studies reporting sensitivity and specificity data for imaging modalities and physical examination tests for long head of biceps (LHB) tendon pathology use arthroscopy as the gold standard. However, there is little published data to validate this as an appropriate benchmark. The aim of this study was to determine the maximum length of the LHB tendon that can be seen at glenohumeral arthroscopy and whether it allows adequate visualisation of common sites of pathology. Seven female cadaveric specimens were studied. Mean age was 74 years (range 44–96 years). Each specimen underwent arthroscopy in lateral decubitus (LD) and beach chair (BC) positions. The LBH-tendon was tagged with a suture placed with a spinal needle marking the intra-articular length and the maximum excursions achieved using a hook and a grasper in both LD and BC positions. T-tests were used to compare data. The mean intra-articular and extra-articular lengths of the tendon were 23.9 mm and 82.3 mm respectively. The mean length of tendon that could be visualised by pulling it into the joint with a hook was significantly less than with a grasper (LD: hook 29.9 mm, grasper 33.9 mm, mean difference 4 mm, p=0.0032. BC: hook 32.7 mm, grasper 37.6 mm, mean difference 4.9 mm, p=0.0001). Using the BC position allowed visualisation of a significantly greater length than the LD position when using either a hook (mean difference 2.86 mm, p=0.0327) or a grasper (mean difference 3.7 mm, p=0.0077). The mean length of the extra-articular part of the tendon visualised using a hook was 6 mm in LD and 8.9 mm in BC. The maximum length of the extra-articular portion visualised using this technique was 14 mm (17%). Pulling the tendon into the joint with a hook does not allow adequate visualisation of common distal sites of pathology in either LD or BC. Although the BC position allows a significantly greater proportion of the tendon to be visualised this represents a numerically small value and is not likely to be clinically significant. The use of a grasper also allowed greater excursion but results in iatrogenic tendon injury which precludes its use. The reported incidence of pathology in Denard zone C (distal to subscapularis) is 80% and in our study it was not possible to evaluate this zone even by using a grasper or maximum manual force to increase excursion. This is consistent with the extremely high rate of missed diagnoses reported in the literature. Surgeons should be aware that the technique of pulling the LHB-tendon into the joint is inadequate for visualising distal pathology and results in a high rate of missed diagnoses. Furthermore, efforts to achieve greater excursion by “optimum” limb positioning intra-operatively do not confer an important clinical advantage and are probably unnecessary.
The development of skills in arthroscopic surgery is essential to the training of modern orthopedic surgeons. Few validated, objective tools exist which track improvement in arthroscopic skills. The purpose of this study was to validate an objective global assessment of arthroscopic skills employing videotape footage of diagnostic arthroscopy performed by participants of various skill levels on a cadaveric knee. A total of 22 participants with varying arthroscopic experience performed a recorded diagnostic knee arthroscopy on a cadaveric knee. Recorded footage of the procedures from an arthroscopic and external view was assessed by five blinded evaluators and scored on a global skills evaluation and checklist evaluation form. Interclass correlation coefficient analyses were used to determine the inter-rater reliability. Mean scores of novice and experienced residents and practicing arthroscopists (based on rank and experience) were compared using a students t-test.Purpose
Method
Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. The purpose of this multicentre randomized double-blind controlled study was to compare the functional outcomes and healing rates of double-row suture techniques with single row repair. Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a double row (DR) or single row (SR) repair. The primary objective was to compare the WORC score at 24 months. Secondary objectives included anatomical outcomes by MRI or ultrasound, the Constant, and ASES scores. A sample size calculation determined that 84 patients provided 80% power with a 50% effect size to detect a statistical difference between groups.Purpose
Method
The purpose of this prospective randomised clinical trial is to examine the effect of acromioplasty on the outcome of arthroscopic rotator cuff repair. Patients included individuals that were referred for assessment after six months of failed conservative management. Following informed consent patients were randomly assigned to receive arthroscopic rotator cuff repair with or without acromioplasty. The surgeon was not blinded to the type of procedure; however, the researcher who performed the follow-up evaluations and the patient was blinded to the surgical protocol. Subacromial decompression (acromioplasty) was performed with release of the coracoacromial ligament off the anterior undersurface of the acromion. The procedure for arthroscopic cuff repair without acromioplasty followed the protocol of arthroscopic cuff repair with acromioplasty, without division of the coracoacromial ligament or resection of the acromion. Both groups experienced the same post-operative rehabilitation protocol. Wound healing and active and passive range of motion were assessed and recorded at six to eight weeks post-operatively. Subsequent post-operative visits occurred at three, six, twelve, eighteen and twenty-four months and included documentation of patient range of motion, patient derived WORC scores (1) and complete ASES scores. Preliminary results suggest, based on a one-tailed t-test, patients that receive a rotator cuff repair with acromioplasty demonstrate a statistically significant improvement (<
0.05) in Quality of Life, based on WORC and ASES scores, compared to the non-acromioplasty group. To date, three patients in the non-acromioplasty group required a revision surgery; two of these patients had a Type III acromion. Arthroscopic rotator cuff repair with arthroscopic acromioplasty in the treatment of full thickness rotator cuff tears is recommended for patients with a Type III acromion.