Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 22 - 22
1 Dec 2016
Degen R Garcia G Bui C McGarry M Lee T Dines J
Full Access

Acute Hill-Sachs (HS) reduction represents a potential alternative method to remplissage for the treatment of an engaging HS lesion. The purpose of this study is to biomechanically compare the stabilising effects of a acute HS reduction technique and remplissage in a complex instability model.

This was a comparative cadaveric study of 6 shoulders. For the acute HS lesion, a unique model was used to create a 30% defect, compressing the subchondral bone while preserving the articular surface in a more anatomic fashion. In addition, a 15% glenoid defect was made in all specimens. The HS lesion was reduced through a lateral cortical window with a bone tamp, and the subchondral void was filled with Quickset (Arthrex) bone cement to prevent plastic deformation. Five scenarios were tested; intact specimen, bipolar lesion, Bankart repair, remplissage with Bankart repair and HS reduction technique with Bankart repair. Translation, kinematics and dislocation events were recorded.

For all 6 specimens no dislocations occurred after either remplissage or the reduction technique. At 90 degrees of abduction and external rotation (ABER), anterior-inferior translation was 11.1 mm (SD 0.9) for the bipolar lesion. This was significantly reduced following both remplissage (5.1±0.7mm; p<0.001) and HS reduction (4.4±0.3mm; p<0.001). For anterior-inferior translation there was no significant difference in translation between the reduction technique and remplissage (p=0.91). At 90 degrees of ABER, the intact specimens average joint stiffness was 7.0±1.0N/mm, which was not significantly different from the remplissage (7.8±0.9 N/mm; p=0.9) and reduction technique (9.1±0.6 N/mm; p=0.50). Compared with an isolated Bankart repair, the average external rotation loss after also performing a remplissage procedure was 4.3±3.5 deg (p=0.65), while average ER loss following HS reduction was 1.1±3.3 deg (p=0.99). There was no significant difference in external rotation between remplissage and the reduction technique (p=0.83).

Similar joint stability was conferred following both procedures, though remplissage had 3.2-degree loss of ER in comparison. While not statistically significant, even slight ER loss may be clinically detrimental in overhead athletes. Overall, the acute reduction technique is a more anatomic alternative to the remplissage procedure with similar ability to prevent dislocation in a biomechanical model, making it a viable treatment option for engaging Hill-Sachs lesions.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 147 - 147
1 Jan 2016
Lee T Lee J Bouzarif G McGarry M Schwarzkopf R
Full Access

INTRODUCTION

Total knee arthroplasty (TKA) is a very successful procedure with good clinical outcomes. However, the effects of obesity on TKA outcomes remain controversial and inconclusive. The objective of this study was to quantify the biomechanical effects of simulated obesity on Cruciate Retaining (CR) and Posterior Stabilized (PS) TKA in human cadaveric knees. We hypothesized that biomechanical characteristics of CR TKA will be less dependent on simulated obesity compared to PS TKA.

METHODS

Eight cadaveric knees (4 male, 4 female) average age 68.4 years (range, 40–86 years) underwent TKA and were tested using a custom knee testing system. Specifically, Cruciate Retaining (CR) and Posterior Stabilized (PS) Lospa Knee System (Corentec Inc.) were implanted and tested sequentially using internal control experimental design. The muscle loading was determined based on the physiological cross-sectional area ratio of the quadriceps and hamstring muscles. The ratios were then applied to CDC data representing the average male height and used to simulate a BMI of 25, 30, and 35 at knee flexion angles (KFA) of 15, 30, 45, 60, 75, and 90 degrees. Patellofemoral and tibiofemoral joint contact areas and pressures were measured using the K-scan sensor system (Tekscan Inc, South Boston, MA). Contact area, force, pressure and peak contact pressure were obtained and analyzed for each specimen. Knee kinematics were quantified using a Microscribe 3DLX digitizer (Revware Inc, Raleigh, North Carolina). Repeated measure analysis of variance with a Tukey post hoc test was used to compare loading conditions. Comparisons between the CR and PS TKA groups were made with a paired t-test. The significance level was set at 0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 148 - 148
1 Jan 2016
Lee T McGarry M Stephenson D Oh JH
Full Access

Introduction

Reverse total shoulder arthroplasty continues to have a high complication rate, specifically with component instability and scapular notching. Therefore, the purpose of this study was to quantify the effects of humeral component neck angle and version on impingement free range of motion.

Methods

A total of 13 cadaveric shoulders (4 males and 9 females, average age = 69 years, range 46 to 96 years) were randomly assigned to two studies. Study 1 investigated the effects of humeral component neck angle (n=6) and Study 2 investigated the effects of humeral component version (n=7). For all shoulders, Tornier Aequalis® Reversed Shoulder implants (Edina, MN) were used. For study 1, the implants were modified to 135, 145 and 155 degree humeral neck shaft angles and for Study 2 a custom implant that allowed control of humeral head version were used.

For biomechanical testing, a custom shoulder testing system that permits independent loading of all shoulder muscles with six degree of freedom positioning was used. (Figure 1) Internal control experimental design was used where all conditions were tested on the same specimen.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 344 - 344
1 Dec 2013
Heckmann N Omid R Wang L McGarry M Vangsness CT Lee T
Full Access

Background:

The purpose of this study was to compare the biomechanical effects of the trapezius transfer and the latissimus dorsi transfer in a cadaveric model of a massive posterosuperior rotator cuff tear.

Methods:

Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane with anatomically based muscle loading. Humeral rotational range of motion and the amount of humeral rotation due to muscle loading were measured. Glenohumeral kinematics and joint reaction forces were measured throughout the range of motion. After testing in the intact condition, the supraspinatus and infraspinatus were resected, simulating a massive rotator cuff tear. The lower trapezius transfer was then performed. Three muscle loading conditions for the trapezius (12N, 24N, 36N) were applied to simulate a lengthened graph as a result of excessive creep, a properly tensioned graph exerting a force proportional to the cross-sectional area of the inferior trapezius, and an over-constrained graph respectively. Next the latissimus dorsi transfer was performed and tested with one muscle loading condition 24N. A repeated-measures analysis of variance was used for statistical analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 345 - 345
1 Dec 2013
Argintar E Heckmann N Wang L Tibone J Lee T
Full Access

Background:

Individuals with large Hill-Sachs lesions may be prone to failure and reoccurrence following standard arthroscopic Bankart repair. Here, the Remplissage procedure may promote shoulder stability through infraspinatus capsulo-tenodesis directly into the lesion. Little biomechanicaldata about the Remplissage procedure on glenohumeral kinematics, stability, and range of motion (ROM) currently exists.

Questions/purposes:

What are the biomechanical effects of Bankart and Remplissage repair for large Hill-Sachs lesions?


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 7 - 7
1 Apr 2012
Lee T Ciampolini J Evans P
Full Access

At the Peninsula NHS Treatment Centre in Plymouth some of the surgeons are UK trained and some trained elsewhere in Europe.

This paper examines the outcomes of a large series of joint replacements from 2006 to 2008 at a minimum of one year follow up to determine whether the place of orthopaedic specialist training makes any difference to the outcome. The same implants were used by all surgeons and the anaesthetic technique and post-operative management was identical.

1700 patients were interviewed by a structured telephone questionnaire with over 92% follow-up and the results entered into a joint replacement database. Additional data about length of stay and blood transfusion was added.

Results will be presented about length of stay, transfusion requirements, any further treatment or hospital attendance relating to the new joint, reoperation, deep or superficial infection, hip dislocation, VTE and patient satisfaction.

The surgeon's place of orthopaedic training was found to make no difference to the surgical outcome.