Lee G Wakelin E Randall A Plaskos C

Aims

Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following total knee arthroplasty (TKA). The aim of this study was to determine whether a surgeon, with robotic assistance, can predict the outcome as assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) for pain (KPS), one year postoperatively, and establish what factors correlate with poor KOOS scores in a well-aligned and balanced TKA.

Methods

A total of 134 consecutive patients who underwent TKA using a dynamic ligament tensioning robotic system with a tibia first resection technique and a cruciate sacrificing ultracongruent TKA system were enrolled into a prospective study. Each TKA was graded based on the final mediolateral ligament balance at 10° and 90° of flexion: 1) < 1 mm difference in the thickness of the tibial insert and that which was planned (n = 75); 2) < 1 mm difference (n = 26); 3) between 1 mm to 2 mm difference (n = 26); and 4) > 2 mm difference (n = 7). The mean one-year KPS score for each grade of TKA was compared and the likelihood of achieving an KPS score of > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high-grade TKA (grade A and B) were analyzed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 27 - 27
1 Oct 2020
Lee G Wakelin E Randall A Plaskos C
Full Access

Introduction

Neither a surgeon's intraoperative impression or computer navigation parameters have been shown to be predictive of postoperative outcomes following TKA. The purpose of this study is to determine 1) whether a surgeon and a robot can predict the 1-year KOOS pain score (KPS) and 2) determine what factors correlate with poor KOOS scores in well aligned and balanced TKA.

Methods

The data of 131 consecutive patients enrolled in a prospective trial was reviewed. All TKAs were performed using a dynamic ligament tensioning robotic system with a tibial first resection technique and a cruciate sacrificing ultracongruent knee implant. Each TKA was graded based on the final recorded mediolateral ligament balance at 10° and 90°: A) <1mm with an implanted insert thickness equal to planned (n=74); B) <1mm (n=25); C) <2mm (n=26); D) >2mm (n=6) (Table-1). The 1-year KPS for each knee grade were compared and the likelihood of achieving an KPS > 90 was calculated. Finally, the factors associated with lower KPS despite achieving a high grade TKA (A/B) was performed. The Mann-Whitney U test and Chi-squared analysis was performed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 7 - 7
1 Oct 2020
Goswami K Clarkson S Dennis DA Klatt BA O'Malley M Smith EL Pelt CE Gililland J Peters C Malkani AL Palumbo B Minter J Goyal N Cross M Prieto H Lee G Hansen E Ward D Bini S Higuera C Levine B Nam D Della Valle CJ Parvizi J
Full Access

Introduction

Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture.

Methods

This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims

The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA.

Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 40 - 40
1 Oct 2019
Lee G Colen D Levin LS Kovach S
Full Access

Introduction

Infection following TKA can be a catastrophic complication that can cause significant pain, morbidity and jeopardize limb viability. The integrity of the soft tissue envelope is critical to successful treatment and infection control. While local tissue flaps can provide adequate coverage for most soft tissue defects around the knee, there are cases that require salvage using microvascular free tissue transfers. The purpose of this study is to evaluate the 1) rate of limb salvage; 2) infection control; and 3) clinical function following free flap coverage for salvage of the infected TKA.

Materials and Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and 7 women with a mean age of 61.2 years (range 39–81). The median number of procedures performed prior to soft tissue coverage was 5 (range 2–9) and all patients had failed at least one 2 stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function. The rate of limb salvage and infection control were recorded.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 56 - 56
1 Oct 2018
Charette R Sloan M Lee G
Full Access

Introduction

Expanded indications and patient demand have significantly increased the number of TKA performed in young and active patients under age 55. While improved materials have decreased the likelihood of early catastrophic wear, concerns remain with the performance and survivorship of TKA implants in this patient population. Therefore, the purpose this study is to evaluate the clinical outcomes, complications, and implant survivorship of TKAs performed in patients under age 55.

Materials and Methods

We retrospectively reviewed 1194 primary TKA performed for the diagnosis of primary knee osteoarthritis performed at our institution between 2013–2016. There were 291 TKA performed in patients under age 55. Patients were excluded if they had 1) prior history of fracture, 2) renal disease, 3) inflammatory joint disease, and 4) required therapeutic anticoagulation. The primary outcome of interest was rate of revision at 30 days, 1, 2, and 5-year time points. Secondary outcomes included postoperative transfusion rate, calculated blood loss, length of stay(LOS), rate of DVT/PE, readmission and reoperation.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 153 - 156
1 Nov 2012
Su EP Perna M Boettner F Mayman DJ Gerlinger T Barsoum W Randolph J Lee G

Pain, swelling and inflammation are expected during the recovery from total knee arthroplasty (TKA) surgery. The severity of these factors and how a patient copes with them may determine the ultimate outcome of a TKA. Cryotherapy and compression are frequently used modalities to mitigate these commonly experienced sequelae. However, their effect on range of motion, functional testing, and narcotic consumption has not been well-studied.

A prospective, multi-center, randomised trial was conducted to evaluate the effect of a cryopneumatic device on post-operative TKA recovery. Patients were randomised to treatment with a cryopneumatic device or ice with static compression. A total of 280 patients were enrolled at 11 international sites. Both treatments were initiated within three hours post-operation and used at least four times per day for two weeks. The cryopneumatic device was titrated for cooling and pressure by the patient to their comfort level.

Patients were evaluated by physical therapists blinded to the treatment arm. Range of motion (ROM), knee girth, six minute walk test (6MWT) and timed up and go test (TUG) were measured pre-operatively, two- and six-weeks post-operatively. A visual analog pain score and narcotic consumption was also measured post-operatively.

At two weeks post-operatively, both the treatment and control groups had diminished ROM and function compared to pre-operatively. Both groups had increased knee girth compared to pre- operatively. There was no significant difference in ROM, 6MWT, TUG, or knee girth between the 2 groups. We did find a significantly lower amount of narcotic consumption (509 mg morphine equivalents) in the treatment group compared with the control group (680 mg morphine equivalents) at up to two weeks postop, when the cryopneumatic device was being used (p < 0.05). Between two and six weeks, there was no difference in the total amount of narcotics consumed between the two groups. At six weeks, there was a trend toward a greater distance walked in the 6MWT in the treatment group (29.4 meters versus 7.9 meters, p = 0.13). There was a significant difference in the satisfaction scores of patients with their cooling regimen, with greater satisfaction in the treatment group (p < 0.0001). There was no difference in ROM, TUG, VAS, or knee girth at six weeks. There was no difference in adverse events or compliance between the two groups.

A cryopneumatic device used after TKA appeared to decrease the need for narcotic medication from hospital discharge to 2 weeks post-operatively. There was also a trend toward a greater distance walked in the 6MWT. Patient satisfaction with the cryopneumatic cooling regimen was significantly higher than with the control treatment.