header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 97 - 97
10 Feb 2023
Gibbons J Bodian C Powell A Sharr J Lash N
Full Access

PFFs are an increasing burden presenting to the acute trauma services. The purpose of this study is to show that cemented revision for Vancouver B2/B3 PFFs is a safe option in the geriatric population, allows early pain-free weight bearing and comparable to a control-group of uncemented stems with regard to return to theatre and revision surgery.

A retrospective review was conducted of all PFFs treated in a Level 1 trauma centre from 2015-2020. Follow up x-rays and clinical course through electronic chart was reviewed for 78 cemented revisions and 49 uncemented revisions for PFF. Primary endpoints were all cause revision and return to theatre for any reason. Secondary endpoints recorded mobility status and all-cause mortality.

In the cemented group there were 73 Vancouver B2, 5 Vancouver B3 PFF; the mean age was 79.7 years and mean radiological follow-up of 11.9 months. In the cementless group there were 32 Vancouver B2 and 17 Vancouver B3 PFFs; with all 49 patients undergoing distally bearing uncemented revision, the mean age was 72.7 years and mean radiological follow-up of 21.3 months.

Patients treated with a cemented prosthesis had significantly higher ASA score (2.94 -v- 2.43, p<0.001). The primary endpoints showed that there was no significant difference in all cause revision 3/78 and 5/49 p=0.077, or return to theatre 13/78 -v- 12/49 p=0.142.

Secondary endpoints revealed no significant difference in in-hospital mortality. The cementless group were more likely to be mobilising without any aid at latest follow-up 35/49 -v- 24/78 p<0.001.

The use of cemented revision femoral component in the setting of PFFs is one option in the algorithm for management of unstable PFFs according to the Vancouver classification. Evidence from this case-control study, shows that the all-cause revision and return to theatre for any cause was comparable in both groups.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups.

BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures.

This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.