Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario.

Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results.

Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters.

Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 34 - 34
1 Dec 2022
Lapner P Pollock J Hodgdon T Sheikh A Shamloo A Fernandez AA McIlquham K Desjardins M Drosdowech D Nam D Rouleau D
Full Access

The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard).

This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by musculoskeletal radiologists prior to revision surgery. A minimum of five synovial capsular tissue biopsies were obtained from five separate regions in the shoulder. Revision shoulder arthroplasty was performed by fellowship-trained shoulder surgeons. Intraoperative tissue samples were taken from five regions of the joint capsule during revision surgery.

Of 98 patients who underwent revision surgery, 71 patients underwent both the synovial biopsy and open biopsy at time of revision surgery. Nineteen percent had positive infection based on PSB, and 22% had confirmed culture positive infections based on intra-operative tissue sampling. The diagnostic accuracy of PSB compared with open biopsy results were as follows: sensitivity 0.37 (95%CI 0.13-0.61), specificity 0.81 (95%CI 0.7-0.91), positive predictive value 0.37 (95%CI 0.13 – 0.61), negative predictive value 0.81 (95%CI 0.70-0.91), positive likelihood ratio 1.98 and negative likelihood ratio 0.77.

A patient with a positive pre-operative PSB undergoing revision surgery had an 37% probability of having true positive infection. A patient with a negative pre-operative PSB has an 81% chance of being infection-free. PSB appears to be of value mainly in ruling out the presence of peri-prosthetic infection. However, poor likelihood ratios suggest that other ancillary tests are required in the pre-operative workup of the potentially infected patient.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 32 - 32
1 Dec 2022
Kamikovski I Woodmass J McRae S Lapner P Jong B Marsh J Old J Dubberley J Stranges G MacDonald PB
Full Access

Previously, we conducted a multi-center, double-blinded randomized controlled trial comparing arthroscopic Bankart repair with and without remplissage. The end point for the randomized controlled trial was two years post-operative, providing support for the benefits of remplissage in the short term in reducing recurrent instability. The aim of this study was to compare the medium term (3 to 9 years) outcomes of patients previously randomized to have undergone isolated Bankart repair (NO REMP) or Bankart repair with remplissage (REMP) for the management of recurrent anterior glenohumeral instability. The rate of recurrent instability and instances of re-operation were examined.

The original study was a double-blinded, randomized clinical trial with two 1:1 parallel groups with recruitment undertaken between 2011 and 2017. For this medium-term study, participants were reached for a telephone follow-up in 2020 and asked a series of standardized questions regarding ensuing instances of subluxation, dislocation or reoperation that had occurred on their shoulder for which they were randomized. Descriptive statistics were generated for all variables. “Failure” was defined as occurrence of a dislocation. “Recurrent instability” was defined as the participant reporting a dislocation or two or more occurences of subluxation greater than one year post-operative. All analyses were undertaken based on intention-to-treat whereby their data was analyzed based on the group to which they were originally allocated.

One-hundred and eight participants were randomized of which 50 in the NO REMP group and 52 in the REMP group were included in the analyses in the original study. The mean number of months from surgery to final follow-up was 49.3 for the NO REMP group and 53.8 for the REMP group. The rates of re-dislocation or failure were 8% (4/52) in the REMP group at an average of 23.8 months post-operative versus 22% (11/50) in the NO REMP at an average of 16.5 months post-operative. The rates of recurrent instability were 10% (5/52) in the REMP group at an average of 24 months post-operative versus 30% (15/50) in the NO REMP group at an average of 19.5 months post-operative. Survival curves were significantly different favouring REMP in both scenarios.

Arthroscopic Bankart repair combined with remplissage is an effective procedure in the treatment of patients with an engaging Hill-Sachs lesion and minimal glenoid bone loss (<15%). Patients can expect favourable rates of recurrent instability when compared with isolated Bankart repair at medium term follw-up.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 26 - 26
1 Dec 2022
Lapner P Pollock J Hodgdon T Zhang T McIlquham K Coupal S Bouliane M McRae S Dubberley J Berdusco R Stranges G Marsh J Old J MacDonald PB
Full Access

Our primary objective was to compare healing rates in patients undergoing arthroscopic rotator cuff repair for degenerative tears, with and without bone channeling. Our secondary objectives were to compare disease-specific quality of life and patient reported outcomes as measured by the Western Ontario Rotator Cuff Index (WORC), American Shoulder and Elbow Surgeons (ASES) score and Constant score between groups.

Patients undergoing arthroscopic rotator cuff repair at three sites were randomized to receive either bone channeling augmentation or standard repair. Healing rates were determined by ultrasound at 6 and 24 months post operatively. WORC, ASES, and Constant scores were compared between groups at baseline and at 3, 6, 12 and 24 months post operatively.

One hundred sixty-eight patients were recruited and randomized between 2013 to 2018. Statistically significant improvements occurred in both groups from pre-operative to all time points in all clinical outcome scores (p < 0 .0001). Intention to treat analysis revealed no statistical differences in healing rates between the two interventions at 24 months post-operative. No differences were observed in WORC, ASES or Constant scores at any time-point.

This trial did not demonstrate superiority of intra-operative bone channeling in rotator cuff repair surgery at 24 months post-operative. Healing rates and patient-reported function and quality of life measures were similar between groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 32 - 32
1 Mar 2021
Lapner P McRae S Leiter J McIlquham K MacDonald P
Full Access

Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the long-term follow-up of single and double row fixation in arthroscopic cuff repair. The purpose of this study was to compare the long-term functional outcomes of single-row and double-row suture techniques for repair of the rotator cuff 10-years post-operatively.

Ninety patients undergoing arthroscopic rotator cuff repair were randomized to receive either single-row or double-row repair. The primary objective was to compare the Western Ontario Rotator Cuff Index (WORC) score 10-years post-operatively. Secondary objectives included comparison of the Constant, and American Shoulder and Elbow Surgeons (ASES) scores and supraspinatus strength between groups. Out of 90 patients originally randomized, 57 returned for the long-term 10-year follow-up.

Baseline demographic data did not differ between groups. The WORC score was not significantly different between groups at long-term follow-up (p=0.13). No statistical differences were observed between groups for the Constant (p=0.51), ASES (p=0.48) scores, or strength scores (p=0.93). A significant improvement was observed between pre-operative and the final 10-year follow-up. There were no differences observed in all outcomes between two and 10-years post-operatively.

No statistically significant differences in functional or quality of life outcomes were identified between single-row and double-row fixation techniques at long-term follow-up.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 34 - 34
1 Mar 2021
MacDonald P Woodmass J McRae S Verhulst F Lapner P
Full Access

Management of the pathologic long-head biceps tendon remains controversial. Biceps tenotomy is a simple intervention but may result in visible deformity and subjective cramping. Comparatively, biceps tenodesis is technically challenging, and has increased operative times, and a more prolonged recovery. The purpose of this study was to determine the incidence of popeye deformity following biceps tenotomy versus tenodesis, identify predictors for developing a deformity, and compare subjective and objective outcomes between those that have one and those that do not.

Data for this study were collected as part of a randomized clinical trial comparing tenodesis versus tenotomy in the treatment of lesions of the long head of biceps tendon. Patients 18 years of age or older with an arthroscopy confirmed biceps lesion were randomized to one of these two techniques. The primary outcome measure for this sub-study was the rate of a popeye deformity at 24-months post-operative as determined by an evaluator blinded to group allocation. Secondary outcomes were patient reported presence/absence of a popeye deformity, satisfaction with the appearance of their arm, as well as pain and cramping on a VAS. Isometric elbow flexion and supination strength were also measured. Interrater reliability (Cohen's kappa) was calculated between patient and evaluator on the presence of a deformity, and logistic regression was used to identify predictors of its occurrence. Linear regression was performed to identify if age, gender, or BMI were predictive of satisfaction in appearance if a deformity was present.

Fifty-six participants were randomly assigned to each group of which 42 in the tenodesis group and 45 in the tenotomy group completed a 24-month follow-up. The incidence of popeye deformity was 9.5% (4/42) in the tenodesis group and 33% (15/45) in the tenotomy group (18 male, 1 female) with a relative risk of 3.5 (p=0.016). There was strong interrater agreement between evaluator and patient perceived deformity (kappa=0.636; p<0.001). Gender tended towards being a significant predictor of having a popeye with males having 6.6 greater odds (p=0.090). BMI also tended towards significance with lower BMI predictive of popeye deformity (OR 1.21; p=0.051). Age was not predictive (p=0.191). Mean (SD) satisfaction score regarding the appearance of their popeye deformity was 7.3 (2.6). Age was a significant predictor, with lower age associated with decreased satisfaction (F=14.951, adjusted r2=0.582, p=0.004), but there was no association with gender (p=0.083) or BMI (p=0.949). There were no differences in pain, cramping, or strength between those who had a popeye deformity and those who did not.

The risk of developing a popeye deformity was 3.5 times higher after tenotomy compared to tenodesis. Male gender and lower BMI tended towards being predictive of having a deformity; however, those with a high BMI may have had popeye deformities that were not as visually apparent to an examiner as those with a lower BMI. Younger patients were significantly less satisfied with a deformity despite no difference in functional outcomes at 24 months. Thus, biceps tenodesis may be favored in younger patients with low BMI to mitigate the risk of an unsatisfactory popeye deformity.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2020
Lapner P Laneuville O Uhthoff HK Zhang T Howard L Pollock J Ruggiero S Trudel G
Full Access

Tears of the rotator cuff tendons are a very common entity. Despite recent advances in arthroscopic rotator cuff repair, the re-tear rate remains high. Thus, new methods to improve healing rates following rotator cuff repair must be sought. The purpose of this prospective randomized double-blind controlled study is to compare the functional outcomes and healing rates of an adjuvant pre-operative bone microfracture technique prior to arthroscopic cuff repair.

Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a percutaneous bone microfracture of the supraspinatus footprint or a “soft tissue needling” technique, in which the pin was passed through the peripheral edges of the rotator cuff, five-seven days prior to index surgery, under ultrasound guidance. Follow-ups were completed at 3, 6, 12 and 24 months post-operatively. Healing status was determined by ultrasound at 6 and 24 months. The primary objective was to compare the WORC score at 24 months. Secondary objectives included the healing status via ultrasound, the Constant, and the ASES scores. A sample size calculation determined that 90 patients provided 80% power to detect a statistical difference between groups.

Baseline demographic data did not differ between groups. No statistical differences were detected in the WORC outcome at any time points (p=0.47, baseline, p=0.60, 3 months, p=0.79, 6 months, p=0.50, 12 months, p=0.54, 24 months). Healing rates did not differ between groups (P=0.34) and no differences were observed in the ASES or Constant Scores at all time-points. Statistically significant improvements occurred in both groups from baseline to all time points in all clinical outcome scores (p < 0 .0001).

No statistically significant differences in primary or secondary outcomes were identified between pre-operative bone microfracture and soft tissue needling techniques prior to arthroscopic rotator cuff repair. This study does not support pre-operative microfracture as a adjuvant technique prior to arthroscopic cuff repair.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 21 - 21
1 Nov 2016
Chen B Garland K Roffey D Poitras S Lapner P Dervin G Phan P Wai E Kingwell S Beaulé P
Full Access

The Spine Adverse Events Severity System (SAVES) and Orthopaedic Surgical Adverse Events Severity System (OrthoSAVES) are standardised assessment tools designed to record adverse events (AEs) in orthopaedic patients. The primary objective was to compare AEs recorded prospectively by orthopaedic surgeons compared to trained independent clinical reviewers. The secondary objective was to compare AEs following spine, hip, knee, and shoulder orthopaedic procedures.

Over a 10-week period, three orthopaedic spine surgeons recorded AEs following all elective procedures to the point of patient discharge. Three orthopaedic surgeons (hip, knee, and shoulder) also recorded AEs for their elective procedures. Two independent reviewers used SAVES and OrthoSAVES to record AEs after reviewing clinical notes by surgeons and other healthcare professionals (e.g. nurses, physiotherapists). At discharge, AEs recorded by the surgeons and independent reviewers were recorded in a database.

AE data for 164 patients were collected (48 spine, 52 hip, 33 knee, and 31 shoulder). Overall, 98 AEs were captured by the independent reviewers, compared to 14 captured by the surgeons. Independent reviewers recorded significantly more AEs than surgeons overall, as well as for each individual group (i.e. spine, hip, knee, shoulder) (p2), but surgeons failed to record minor events that were captured by the independent reviewers (e.g. urinary retention and cutaneous injuries; AEs Grade 0.05). AEs were reported in 21 (43.8%), 19 (36.5%), 12 (36.4%), and five (16.1%) spine, hip, knee, and shoulder patients, respectively. Nearly all reported AEs required only simple or minor treatment (e.g. antibiotic, foley catheter) and had no effect on outcome. Two patients experienced AEs that required invasive or complex treatment (e.g. surgery, monitored bed) that had a temporary effect on outcome.

Similar complication rates were reported in spine, hip, knee, and shoulder patients. Independent reviewers reported more AEs compared to surgeons. These findings suggest that independent reviewers are more effective at capturing AEs following orthopaedic surgery, and thus, could be recruited in order to capture more AEs, enhance patient safety and care, and maximise different complication diagnoses in alignment with proposed diagnosis-based funding models.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 78 - 78
1 Nov 2016
Huang A Thavorn K Katwyk S Lapner P
Full Access

The optimal approach to arthroscopic repair of the rotator cuff is controversial, and both single row and double row fixation methods are commonly used. Which construct yields the highest efficacy is not clear. Given the current era of increasing costs in which health care delivery models are aiming for improved efficiencies and optimal outcomes, a cost-effectiveness study was performed to inform the decision making process of the utilisation of single versus double row repair. The purpose of this study was to evaluate the cost-effectiveness of single row versus double row constructs in patients undergoing arthroscopic rotator cuff repair.

A cost-utility analysis was performed. Health resource use and outcome data were obtained from a previous prospective randomised controlled trial in which 90 patients were randomised to two treatment arms, single row rotator cuff repair (n=48) and double row (n=42). The patients were followed over a two-year span from the time of initial surgery. Unit cost data were captured using case costs collected from the hospital database and the Ontario Schedule of Benefits. Utility values were derived from published literature. The incremental cost effectiveness ratio (ICER), defined as the difference in cost between the two types of rotator cuff fixation divided by the difference in quality adjusted life years (QALY), was determined.

Double row fixation was more costly ($2,279.94 versus $1,587.37) but was more effective than the single row method (QALY of 4.073 versus 4.055). An incremental cost-effectiveness ratio was estimated to be $38,504.92 per QALY for double row fixation relative to single row. This is well below the commonly used willingness to pay threshold of $50,000/QALY. Subgroup analysis demonstrated that patients with larger rotator cuff tears (>3cm) had a lower ICER, suggesting that double-row fixation may be more cost-effective in more severe tears.

Double row rotator cuff fixation is a cost-effective option compared to single row rotator cuff repair with an ICER of $38,504.92/QALY, well within the accepted willingness to pay threshold of $50,000/QALY. Furthermore, the ICER between single and double row fixation improved with larger rotator cuff tears (>3cm), suggesting an additional benefit of a double row construct in those cases.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 83 - 83
1 Sep 2012
Chaudhary R Bell K Lapner P
Full Access

Purpose

Tenodesis of the long head of biceps is an established technique for management of biceps pathology including tears, instability, and chronic tendinosis intractable to non-operative management. Very few studies have reported on clinical outcomes of all-arthroscopic, non-interference, biceps tenodesis techniques. The purpose of this study is to evaluate the functional and quality of life outcomes of patients treated with an all-arthroscopic biceps tenodesis with a suture anchor.

Method

Case Series Level 4 Evidence

Fifty-eight (58) patients with a mean age of 58.5 years were treated with an arthroscopic biceps tenodesis in a single surgeons practice. A single suture anchor was used with a non-interference technique, either in isolation or in association with an arthroscopic rotator cuff repair. A retrospective analysis was performed on prospectively collected outcome measures on patients with a minimum one-year follow-up. Patients were evaluated with an ASES, Constant, and WORC scores pre-operatively and at 6 and 12 months post-operatively. In addition, patients were questioned post-operatively as to whether they experienced any biceps cramping, fatigue, or cosmetic deformity (popeye sign).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 152 - 152
1 Sep 2012
Lapner P Bell K Sabri E Rakhra K McRae S Leiter J MacDonald PB
Full Access

Purpose

Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. The purpose of this multicentre randomized double-blind controlled study was to compare the functional outcomes and healing rates of double-row suture techniques with single row repair.

Method

Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a double row (DR) or single row (SR) repair. The primary objective was to compare the WORC score at 24 months. Secondary objectives included anatomical outcomes by MRI or ultrasound, the Constant, and ASES scores. A sample size calculation determined that 84 patients provided 80% power with a 50% effect size to detect a statistical difference between groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 84 - 84
1 Sep 2012
Lapner P Bell K Sabri E Rakhra K Athwal GS
Full Access

Purpose

Controversy exists regarding the optimal technique of subscapularis mobilization during shoulder arthroplasty. The purpose of this multicentre randomized double-blind study was to compare the functional outcomes and healing rates of the lesser tuberosity osteotomy (LTO) to the subscapularis tenotomy (ST).

Method

Patients undergoing shoulder arthroplasty were randomized to receive either a LTO or ST. The primary outcome was to compare subscapularis strength, as measured by an electronic hand-held dynamometer at 12 months. Secondary outcomes included range of motion, WOOS, Constant and ASES scores. A sample size calculation determined that 80 patients provided 80% power with a 50% effect size to detect a significant difference between groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 173 - 173
1 Sep 2012
Chaudhary R Bell K Lapner P
Full Access

Purpose

An open superior capsular shift is a well-established technique for the management of patients with multidirectional shoulder laxity and the absence of a Bankart lesion. Few studies have reported on functional and quality of life outcomes using arthroscopic technique for shoulder stabilization using superior capsular shift in patients with no Bankart lesion. The purpose of this study was to assess the functional and quality of life outcome scores following shoulder stabilization with a selective arthroscopic superior capsular shift with suture anchors, for treatment of multidirectional laxity and the absence of a Bankart lesion.

Method

Case Series Level 4 Evidence

Thirty-six (36) patients with a mean age of 30.8 years, with a diagnosis of recurrent anterior atraumatic shoulder instability, and no Bankart lesion, were identified in a single surgeons practice. These patients underwent an arthroscopic shoulder stabilization with an anterior inferior to superior capsular shift. The labrum was arthroscopically released from the anterior/inferior glenoid and was shifted superiorly in conjunction with a capsular plication. A retrospective analysis was performed on prospectively collected outcome scores of patients who had with a minimum of 1 year of follow-up. The ASES and WOSI scores were administered pre-operatively and at 6 and 12 month follow-up. The presence of a positive post-operative apprehension sign was also recorded on follow-up.