The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up.Aims
Methods
This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.Aims
Methods
We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score.Aims
Methods
The purpose of this study was to report functional outcome scores following arthroscopic acetabular chondral procedures using the U.K. Non-Arthroplasty Hip Registry (NAHR). Data on adult patients who underwent hip arthroscopy between January 2012 and December 2018 was extracted from the NAHR. Patients who underwent femoral sided chondral procedures were excluded. Patients who underwent osteophyte excision or a concurrent extra-articular procedure were also excluded. Cases were then classified according to the acetabular chondral procedure performed – ‘chondroplasty’, ‘microfracture’ or ‘none’ (no chondral procedure recorded). Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months.Background
Methods
The aim of this study was to use registry data to report and compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum. Data on adult patients who underwent arthroscopic labral debridement or repair between January 2012 and March 2019 was extracted from the UK Non-Arthroplasty Hip Registry dataset. Patients who underwent microfracture, osteophyte excision or a concurrent extra-articular procedure were excluded. Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months.Objectives
Methods
This study aimed to investigate the effect of body mass index (BMI) on functional outcome following hip preservation surgery using the U.K. Non-Arthroplasty Hip Registry (NAHR). Data on adult patients who underwent hip arthroscopy or periacetabular osteotomy (PAO) between January 2012 and December 2018 was extracted from the UK Non-Arthroplasty Hip Registry dataset allowing a minimum of 12 months follow-up. Data is collected via an online clinician and patient portal. Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 monthsBackground
Methods
Slipped capital femoral epiphysis (SCFE) creates a complex deformity of the hip that can result in cam type of femoroacetabular impingement (FAI), which may in turn lead to the early development of osteoarthritis of the hip. The purpose of this study was to evaluate the existing literature reporting on the efficacy of hip arthroscopic treatment of patients with FAI secondary to SCFE. A systematic computer search was conducted based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using Embase, PubMed (Medline), and Cochrane Library up to November 2019. Data such as patient demographics, surgical outcomes and complications that described arthroscopic surgery following FAI secondary to SCFE were retrieved from eligible studies. Two authors independently reviewed study inclusion and data extraction with independent verification.Background
Methods
This paper aims to review the evidence for patient-related factors associated with less favourable outcomes following hip arthroscopy. Literature reporting on preoperative patient-related risk factors and outcomes following hip arthroscopy were systematically identified from a computer-assisted literature search of Pubmed (Medline), Embase, and Cochrane Library using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and a scoping review.Aims
Methods
Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries. We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years Objectives
Methods
In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC. A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method.Aims
Patients and Methods