Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 75 - 75
17 Apr 2023
Tierney L Kuiper J Williams M Roberts S Harrison P Gallacher P Jermin P Snow M Wright K
Full Access

The objectives of the study were to investigate demographic, injury and surgery/treatment-associated factors that could influence clinical outcome, following Autologous Chondrocyte Implantation (ACI) in a large, “real-world”, 20 year longitudinally collected clinical data set.

Multilevel modelling was conducted using R and 363 ACI procedures were suitable for model inclusion. All longitudinal post-operative Lysholm scores collected after ACI treatment and before a second procedure (such as knee arthroplasty but excluding minor procedures such as arthroscopy) were included. Any patients requiring a bone graft at the time of ACI were excluded. Potential predictors of ACI outcome explored were age at the time of ACI, gender, smoker status, pre-operative Lysholm score, time from surgery, defect location, number of defects, patch type, previous operations, undergoing parallel procedure(s) at the time of ACI, cell count prior to implantation and cell passage number.

The best fit model demonstrated that for every yearly increase in age at the time of surgery, Lysholm scores decreased by 0.2 at 1-year post-surgery. Additionally, for every point increase in pre-operative Lysholm score, post-operative Lysholm score at 1 year increased by 0.5. The number of cells implanted also impacted on Lysholm score at 1-year post-op with every point increase in log cell number resulting in a 5.3 lower score. In addition, those patients with a defect on the lateral femoral condyle (LFC), had on average Lysholm scores that were 6.3 points higher one year after surgery compared to medial femoral condyle (MFC) defects. Defect grade and location was shown to affect long term Lysholm scores, those with grade 3 and patella defects having on average higher scores compared to patients with grade 4 or trochlea defects.

Some of the predictors identified agree with previous reports, particularly that increased age, poorer pre-operative function and worse defect grades predicted poorer outcomes. Other findings were more novel, such as that a lower cell number implanted and that LFC defects were predicted to have higher Lysholm scores at 1 year and that patella lesions are associated with improved long-term outcomes cf. trochlea lesions.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 20 - 20
11 Apr 2023
Hamilton R Holt C Hamilton D Garcia A Graham C Jones R Shilabeer D Kuiper J Sparkes V Khot S Mason D
Full Access

Mechanical loading of joints with osteoarthritis (OA) results in pain-related functional impairment, altered joint mechanics and physiological nociceptor interactions leading to an experience of pain. However, the current tools to measure this are largely patient reported subjective impressions of a nociceptive impact. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this study, we gathered preliminary data on healthy volunteers to analyse whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus.

Following ethical approval, 15 healthy volunteers completed 5 movement and stationary activities in 2 conditions; a control setting and then repeated with an applied quantified thermal pain stimulus to their right knee. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes for skin temperature and conductivity and photoplethysmography (PPG) sensors were manually timestamped to the integrated system.

Pilot data showed EMG, GRF and IMU fluctuations within 0.5 seconds of each other in response to a thermal trigger. Preliminary analysis on the 15 participants tested has shown skin conductance, PPG, EMG, GRFs, joint angles and kinematics with varying increases and fluctuations during the thermal condition in comparison to the control condition.

Preliminary results suggest physiological and biomechanical data outputs can be linked and identified in response to a defined nociceptive stimulus. Study data is currently founded on healthy volunteers as a proof-of-concept. Further exploratory statistical and sensor readout pattern analysis, alongside early and late-stage OA patient data collection, can provide the information for potential development of wearable nociceptive sensors to measure disease progression and treatment effectiveness.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 67 - 67
1 May 2017
Bhattacharjee A McCarthy H Tins B Kuiper J Roberts S Richarson J
Full Access

Background

Structural and functional outcome of bone graft with first or second generation autologous chondrocyte implantation (ACI) in osteochondral defects has not been reported.

Methods

Seventeen patients (mean age of 27±7 years, range 17–40), twelve with osteochondritis dissecans (OD) (ICRS Grade 3 and 4) and five with isolated osteochondral defect (OCD) (ICRS Grade 4) were treated with a combined implantation of a unicortical autologous bone graft with ACI (the Osplug technique). Functional outcome was assessed with Lysholm scores. The repair site was evaluated with the Oswestry Arthroscopy Score (OAS), MOCART score and ICRS II histology score. Formation of subchondral lamina and lateral integration of the bone grafts were evaluated from MRI scans.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 240 - 240
1 Jul 2014
Bhattacharjee A Kuiper J Harrison P Roberts S Richardson J
Full Access

Summary

Randomised controlled study evaluating new bone formation in vivo in fracture non-unions by bone marrow derived stromal cells (BMSC). These cells do not show statistically significant new bone formation. Age of the patient during fracture, diabetes and doubling time had been observed to be correlated with fracture healing.

Introduction

Regenerating new bone by cell therapy could provide therapeutic options in many conditions such as fracture non-unions and osteo-chondral defect regeneration in advance OA. In this randomised controlled study we evaluated the efficacy of new bone formation by bone marrow derived stromal cells (BMSC) in patients with non-union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 119 - 119
1 Aug 2012
Kumar KS Jaiswal A Gilbert R Carrothers A Kuiper J Richardson J
Full Access

Background

Hip resurfacing has resurged in the last decade due to a renewed interest in metal on metal bearing. One of the proposed advantages is ease of revision of the femoral component. Short term functional results after femoral revision are similar to those after conventional total hip replacement. Survival and function after revision of the acetabular component only or of both components have not been reported. We aimed to assess hip function and implant survival after revision of the acetabular component for failed Birmingham hip resurfacing (BHR).

Methods

The Oswestry Outcome Centre collected data prospectively on 5000 patients who underwent hip resurfacing between 1997 and 2002. Of these, 182 hips were revised: 42% had revision of the femoral component only, 8% revision of the acetabular component only, and 50% revision of both components. This study analyzed patients who had revision of the acetabular component, either in isolation or in combination with the femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 271 - 277
1 Feb 2009
Toms AD Barker RL McClelland D Chua L Spencer-Jones R Kuiper J

The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted trays in the contained defects is equivalent to that of an uncemented primary knee replacement. However, there is little biomechanical evidence on which to base a decision in the treatment of uncontained defects. We undertook a laboratory-based biomechanical study comparing three methods of graft containment in segmental medial tibial defects and compared them with the use of a modular metal augment to bypass the defect.

Using resin models of the proximal tibia with medial defects representing either 46% or 65% of the medial cortical rim, repair of the defect was accomplished using mesh, cement or a novel bag technique, after which impaction bone grafting was used to fill the contained defects and a tibial component was cemented in place. As a control, a cemented tibial component with modular metal augments was used in identical defects. All specimens were submitted to cyclical mechanical loading, during which cyclical and permanent tray displacement were determined.

The results showed satisfactory stability with all the techniques except the bone bag method. Using metal augments gave the highest initial stability, but obviously lacked any potential for bone restoration.