Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 82 - 82
2 Jan 2024
Özer Y Karaduman D Karanfil Y Çiftçi E Balci C Doğu B Halil M Cankurtaran M Korkusuz F
Full Access

Osteoarthritis (OA) of the knee joint is a complex peripheral joint disorder with multiple risk factors. We aimed to examine the relationship between the grade of knee OA and anterior thigh length (ATL).

A total of 64 geriatric patients who had no total hip or knee replacement with a BMI of ≥30 were evaluated. Patients' OA severity was determined by two independent experts from bilateral standing knee radiographs according to the Kellgren-Lawrence (KL) grade. Joint cartilage structure was assessed using ultrasonography (US). The ATL, the gastrocnemius medialis (GC), the rectus femoris (RF) and the rectus abdominis (RA) skeletal muscle thicknesses as well as the RF cross-sectional area (CSA) were measured with US. Sarcopenia was diagnosed using the handgrip strength (HGS), 5× sit-to-stand test (5xSST) and bioelectrical impedance analysis.

The median (IQR) age of participants was 72 (65–88) years. Seventy-one per cent of the patients (n=46) were female. They were divided into the sarcopenic obese (31.3 %) and the non-sarcopenic obese (68.8%) groups. KL grade of all patients correlated negatively with the ATL (mm) and the thickness of GC (mm) (r= -0,517, p<0.001 and r= -0.456, p<0.001, respectively). In the sarcopenic obese and the non-sarcopenic obese groups, KL grade of the all patients was negatively correlated with ATL (mm) and thickness of GC (mm) (r= -0,986, p<0.001; r= -0.456, p=0.05 and r= -0,812, p=0.002; r= −0,427, p=0.006). KL grade negatively correlated with the RF thickness in the sarcopenic obese group (r= -0,928, p=0.008).

In conclusion, OA risk may decrease as the lower extremity skeletal muscle mass increases.

Acknowledgments: Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 87 - 87
2 Jan 2024
Vargel I Açil M Tuncel S Baysal N Hartuç I Okur H Korkusuz F
Full Access

Deriving autologous mesenchymal stem cells (MSCs) from adipose tissues without using enzymes requires sophisticated biomedical instruments. Applied pressure on tissues and cells are adjusted manually although centrifugation and filtration systems are frequently used. The number of derived MSCs therefore could differ between instruments. We compared the number of MSCs obtained from four commercially available devices and our newly designed and produced instrument (A2, B3, L3, M2 and T3). Three-hundred mL of adipose tissue was obtained from a female patient undergoing liposuction using the transillumination solution. Obtained tissue was equally distributed to each device and handled according to the producers' guides. After handling, 3 mL stromal vascular fraction (SVF) was obtained from each device. Freshly isolated SVF was characterized using multi-color flow cytometry (Navios Flow Cytometer, Beckman Coulter, USA). Cell surface antigens were chosen according to IFATS and ISCT. CD31-FITC, CD34-PC5,5, CD73-PE, CD90-PB and CD45-A750 (Backman Coulter, USA) fluorochrome-labeled monoclonal antibodies were assessed. Markers were combined with ViaKrome (Beckman Coulter, USA) to determine cell viability. At least 105 cells were acquired from each sample. A software (Navios EX, Beckman Coulter, USA) was used to create dot plots and to calculate the cell composition percentages. The data was analyzed in the Kaluza 2.1 software package (Beckman Coulter, USA). Graphs were prepared in GraphPad Prism. CD105 PC7/CD31 FITC cell percentages were 23,9%, 13,5%, 24,6%, 11,4% and 28,8% for the A2, B3, L3, M2 and T3 devices, respectively. We conclude that the isolated MSC percentage ranged from 11,4% to 28,8% between devices. The number of MSCs in SVF are key determinants of success in orthobiological treatments. Developing a device should focus on increasing the number of MSCs in the SVF while preserving its metabolic activity.

Acknowledgments: Scientific and Technological Research Council of Türkiye (TÜBİTAK)- Technology and Innovation Funding Program Directorate (TEYDEB) funded this project (#321893). Servet Kürümoğlu and Bariscan Önder of Disposet Ltd., Ankara, Türkiye (www.disposet.com) contributed to the industrial design and research studies. Ali Tuncel and Feza Korkusuz are members of the Turkish Academy of Sciences (TÜBA). Nilsu Baysal was funded by the STAR Program of TÜBITAK Grant # 3210893.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 32 - 32
2 Jan 2024
Depboylu F Yasa E Poyraz Ö Korkusuz F
Full Access

Decreasing the bulk weight without losing the biomechanical properties of commercial pure titanium (Cp-Ti) medical implants is now possible by using Laser Powder Bed Fusion (L-PBF) technology. Gyroid lattice structures that have precious mechanical and biological advantages because of similarity to trabecular bone. The aim of the study was to design and develop L-PBF process parameter optimization for manufacturing gyroid lattice Cp-Ti structures. The cleaning process was then optimized to remove the non-melted powder from the gyroid surface without mechanical loss.

Gyroid cubic designs were created with various relative densities by nTopology. L-PBF process parameter optimization was progressed using with Cp-Ti (EOS TiCP Grade2) powder in the EOS M290 machine to achieve parts that have almost full dense and dimensional accuracy. The metallography method was made for density. Dimensional accuracy at gyroid wall thicknesses was investigated between designed and manufactured via stereomicroscope, also mechanical tests were applied with real time experiment and numerical analysis (ANSYS). Mass loss and strut thickness loss were investigated for chemical etching cleaning process.

Gyroid parts had 99,5% density. High dimensional accuracy was achieved during L-PBF process parameters optimization. Final L-PBF parameters gave the highest 19% elongation and 427 MPa yield strength values at tensile test. Mechanical properties of gyroid were controlled with changing relative density. A minute chemical etching provided to remove non-melted powders.

Compression test results of gyroids at numerical and real-time analysis gave unrelated while deformation behaviors were compatible with each other. Gyroid Cp-Ti osteosynthesis mini plates will be produced with final L-PBF process parameters. MTT cytotoxicity test will be characterized for cell viability.

Acknowledgements This project is granted by TUBITAK (120N943). Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 5 - 5
2 Jan 2024
Karaçoban L Gizer M Fidan BB Kaplan O Çelebier M Korkusuz P Turhan E Korkusuz F
Full Access

Osteoarthritis (OA) is a disabling disease depriving the quality of life of patients. Mesenchymal stem cells (MSCs) are recently used to modify the inflammatory and degenerative cascade of the disease. Source of MSCs could change the progression and symptoms of OA due to their different metabolomic activities. We asked whether MSCs derived from the infrapatellar fat (IPF), synovium (Sy) and subcutaneous (SC) tissues will decrease inflammatory and degenerative markers of normal and OA chondrocytes and improve regeneration in culture. Tissues were obtained from three male patients undergoing arthroscopic knee surgery due to sports injuries after ethical board approval. TNFa concentration decreased in all MSC groups (Sy=156,6±79, SC=42,1±6 and IPF=35,5±3 pg/ml; p=0,036) on day 14 in culture. On day seven (Sy=87,4±43,7, SC=23±8,9 and IPF=14,7±3,3 pg/ml, p=0,043) and 14 (Sy=29,1±11,2, SC=28,3±18,5 and IPF=20,3±16,2 pg/ml, p=0,043), MMP3 concentration decreased in all groups. COMP concentration changes however were not significant. Plot scores of tissues for PC2-13,4% were significantly different. Based on the results of liquid chromatography-mass spectrometry (LC-MS) metabolomics coupled with recent data processing strategies, clinically relevant seven metabolites (L-fructose, a-tocotrienol, coproporphyrin, nicotinamide, bilirubin, tauro-deoxycholic acid and galactose-sphingosine) were found statistically different (p<0.05 and fold change>1.5) ratios in tissue samples. Focusing on these metabolites as potential therapeutics could enhance MSC therapies.

Acknowledgment: Hacettepe University, Scientific Research Projects Coordination Unit (#THD-2020-18692) and Turkish Society of Orthopedics and Traumatology (#TOTBID-89) funded this project. Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 92 - 92
2 Jan 2024
Fidan B Demirdis I Çiftçi E Aydinli H Kaplan O Çelebier M Boyacioglu Ö Korkusuz P Karanfil Y Korkusuz F
Full Access

Platelet Rich Plasma (PRP), either rich (L-PRP) or poor (P-PRP) of leukocytes, is frequently used as an anti-inflammatory and regenerative tool in osteoarthritis (OA). PRP contains proteins but not genes as it is derived from megakaryocytes. Proteomics but not metabolomics of PRP was recently studied. Metabolomics is a field of ‘omics’ research involved in comprehensive portrayal of the small molecules, metabolites, in the metabolome. These small molecules can be endogenous metabolites or exogenous compounds found in an organism (1). Our aim was to determine the difference between L-PRP and P-PRP.

A cross-sectional clinical study was designed in six recreational male athletes between the ages of 18 and 35 years. 3 mL P-PRP and 3 mL -LPRP was prepared from 60 mL of venous blood after treating with 9 mL of sodium citrate and centrifugation at 2.700 rpm for 10 min. Half of the prepared PRP's were frozen at −20°C for a week. Fresh and frozen samples were analyzed at the Q-TOF LC/MS device after thawing to room temperature.

Untargeted metabolomic results revealed that the metabolomic profile of the L-PRP and P-PRP were significantly different from each other. A total of 33.438 peaks were found. Statistically significant (p<0.05) peaks were uploaded to the MetaboAnalyst 5.0 platform. Exogenous out of 2.308 metabolites were eliminated and metabolites found significant for our study were subjected to pathway analysis. Steroid biosynthesis, sphingolipid metabolism and metabolism of lipid pathways were affected. In the L-PRP samples, Nicotinamide riboside (FC: 2.2), MHPG (FC: 3.0), estrone sulfate (FC: 7.5), thiamine diphosphate (FC: 2.0), leukotriene E4 (FC: 7.5), PC(18:1 (9Z)e/2:0) (FC: 9.8) and Ap4A (FC: 2.1) were higher compared to P-PRP. C24 sulfatide (FC: −11.8), 3-hexaprenyl-4,5-dihydroxybenzoic acid (FC: −2.8) metabolites were furthermore lower in P-PRP. Clinical outcomes of PRP application should consider these metabolic pathways in future studies (2).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 54 - 54
2 Jan 2024
İlicepinar Ö Imir M Cengiz B Gürses S Menderes Y Turhan E Dönmez G Korkusuz F
Full Access

Hop tests are used to determine return to sports after ACL reconstruction. They mostly measure distance and symmetry but do not assess kinematics and kinetics. Recently, biomechanical evaluations have been incorporated into these functional jump tests for the better assessment of return to sport. We assessed the sagittal plane range of motion (ROM) of the knee, the deviation axis of rotation (DAOR), and the vertical ground reaction force (vGRF) normalized to body weight in nine healthy participants during the single leg (SLH) and crossover hop tests (COHT).

Participants' leg lengths were measured. Jumping distances were marked in the test area as being 4/5 of the leg length. Four sensors were placed on the thighs, the legs and the feet. These body parts were handled as a single rigid body. Eight 480 Hz cameras were used to capture the movements of these rigid bodies. vGRF at landing were measured using a force plate (Bertec, Inc, USA). The ROM of the knee joint and the DAOR were obtained from kinematic data.

Participants' joint kinematics metrics were similar in within-subjects statistical tests for SLH and COHT. We therefore asked whether the repeated vGRF normalized to body weight will be similar in both legs during these jumps. Joint kinematics metrics however were different in between subjects indicating the existence of a personalized jumping strategy. These hop tests can be recorded at the beginning of the training season for each individual, which can establish a comparative evaluation database for prospective lower extremity injury recovery and return to sport after ACL injury.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 142 - 142
2 Jan 2024
Korkusuz F
Full Access

Disease modifying approaches are commonly applied in OA patients. An aging society with better life expectancies is increasing in Europe and the globe. Orthobiologics cover intraarticular hyaluronan injections and also cellular therapies. Cellular therapies range from platelet rich plasma (PRP) applications to exosomes. Short term follow-up of limited number of patients revealed favorable results in clinical cellular therapies. Most of these studies evaluated decrease of pain and increase in function. Recent basic science studies focused on the action mechanism of orthobiologic therapies however patient perspective is less studied. Our research team has recently performed a qualitative study on the patient perspective of hyaluronan injection of the knee joint. Findings of that study will be shared and future patient knowledge based options on orthobiologics will be discussed.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 106 - 106
1 Mar 2021
Torgutalp SS Babayeva N Kara OS Özkan Ö Güdemez G Korkusuz F
Full Access

Osteoporosis is a common disorder characterized by low bone mass and reduced bone quality that affects the bone strength negatively and leads to increased risk of fracture. Bone mineral density (BMD) has been the standard instrument for the diagnosis of osteoporosis and the determination of fracture risk. Despite the approximation of the bone mass, BMD does not provide information about the bone structure. Trabecular bone score (TBS), which provides an indirect evaluation of skeletal microarchitecture, is calculated from dual X-ray absorptiometry and a simple and noninvasive method that may contribute to the prediction of osteoporotic fractures in addition to the measure of bone density. The goal of this study was to determine the mean TBS values in healthy postmenopausal women and the overall association between TBS and demographic features, bone mineral density of the lumbar spine and femoral neck and bone mineral density to body mass index ratio (BMD/BMI) of the lumbar spine. Fifty-three postmenopausal healthy women participated. The bone mineral density of the lumbar spine and femoral neck were measured dual X-ray absorptiometry. Anteroposterior lumbar spine acquisitions were used to calculate TBS for L1-L4. Age, height, weight, BMI and the ratio of BMD to BMI, which was considered to be a simple tool for assessing fracture risk in especially obese individuals, were calculated. The relationship between TBS and other variables was examined using Spearman's rank correlation coefficients. Mean BMD of the lumbar spine and the femoral neck were 0.945 ± 0.133 and 0.785 ± 0.112 g/cm2, respectively (Table 1). Mean TBS was 1.354 ± 0.107. There was a significant positive moderate correlation between TBS and total lumbar BMD/BMI ratio (r=0.595, pTBS values of postmenopausal women were negatively correlated with age and BMI and positively with bone mineral density and BMD/BMI ratio. The ratio between lumbar BMD and BMI presented a stronger correlation with TBS than that of BMD with TBS. Because of the better correlation, the BMD/BMI ratio may be used as a simple tool for the assessment of the risk of fractures. Further investigation may be needed to evaluate the factors influencing exercise intervention on TBS on this population of patients.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 107 - 107
1 Mar 2021
Çiftçi-Dede E Korkusuz F Korkusuz P
Full Access

Mesenchymal stem cell (MSC) exosomes are intracellular vesicles, which can regulate transcription and control gene expression through the molecules they carry, easily enter into the target cell, contain no regenerative effect, and do not produce an immune response. There are different methods in the literature to obtain these vesicles. However, studies on the isolation of MSC-derived exosomes and their comparative characterization using magnetically active cell sorting (MACS) and ultracentrifugation methods are lacking. The most appropriate isolation method for MSC-derived exosomes can be determined by comparing the isolation and characterization parameters of mesenchymal stem cells using magnetically active cell sorting and ultracentrifugation methods. The aim of this study was to define the advantages and disadvantages of the methods used for determining the purpose-oriented method. Human bone marrow-derived mesenchymal stem cells were cultured in standard MSC culture conditions (37ºC and 5% CO 2). Exosomal contamination was prevented by removal of exosomes from the serum that used in the standard growth medium. For exosome isolation of the cells reaching sufficient density, the media were replaced with new ones every two days, the old media were collected in liquid refrigerated with liquid nitrogen and stored at −80ºC. Part of the accumulated exosomes were isolated by using the MACS method, while the other was isolated by using the ultracentrifugation method, which included serial centrifugation steps. The amount of protein contained in the phosphate buffer solution in which the exosomes were reconstituted was determined by microplate reader using the BCA kit. Based on the protein concentration obtained, exosomes were read by means of a dye flow cytometer with fluorescent antibodies attached to surface markers specific to CD9, CD63, and CD81 specific for exosomes by latex beads. Finally, the exosomes were stained with uranyl acetate and phosphotungstic acid and then placed on 200 mesh and formvar-carbon film coated grids. Exosomes were isolated using both ultracentrifugation and MACS methods. While ultra-large amounts of exosomes can be isolated by ultracentrifugation method, MACS method provides a lower amount of isolation. Exosomes with magnetically active cell sorting are selected with specific surface markers, therefore, exosomal purity is thought to be higher. Exosomes which were isolated by both ultracentrifugation and MACS methods were monitored by using transmission electron microscopy and they were not found to be morphologically different. In conclusion, MACS and ultracentrifugation are effective methods for the isolation of human bone marrow-derived MSC exosomes. Both methods have advantages and disadvantages. Exosomes can be isolated together with magnetic beads using the MACS method. In the ultracentrifuge method, cleaner exosomes can be isolated. While the exosomes are isolated by MACS, they can also be characterized by beads.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 86 - 86
1 Dec 2020
Bal Z Kaito T Ishiguro H Okada R Kanayama S Kushioka J Kodama J Chijimatsu R Korkusuz P Dede EÇ Gizer M Yoshikawa H Korkusuz F
Full Access

To prevent the reported side effects of rhBMP-2, an important cytokine with bone forming capacity, the sustained release of rhBMP-2 is highly important. Synthetic copolymer polylactic acid-polyethylene glycol (PLA-PEG) is already shown to be a good carrier for rhBMP-2. The nano-sized hydroxyapatite (nHAp) is mentioned to be superior to conventional hydroxyapatite due to its decreased particle size which increases the surface area, so protein-cell adhesion and mechanical properties concomitantly. In the literature no study is reported with PLA-PEG / rhBMP-2/ nHAp for bone regeneration. In this study, we assessed the controlled release profile of rhBMP-2 from the novel biomaterial of PLA-PEG / rhBMP-2 / nHAp in vitro and evaluated the bone forming capacity of the composite in rat posterolateral spinal fusion (PSF) model in vivo.

Composites were prepared via addition of rhBMP-2 (0µg, 3µg or 10µg) and nHAp (12.5mg) into PLA-PEG (5mg) + acetone solution and shaping. The release kinetics of the cytokine from the composites with 5µg BMP-2 was investigated by ELISA. The effect of nHAp and nHAp with rhBMP-2 on cell differentiation (rat BMSC cells, passage 3) was tested with ALP staining. In vivo bone formation was investigated by PSF on L4-L5 in a total of 36 male SD rats and weekly µCT results and histology at 8th weeks post operation were used for assessment of the bone formation. All animal experiments was approved by the institutional review board confirming to the laws and regulations of Japan.

The composite showed an initial burst release in the first 24 hours (51.7% of the total released rhBMP-2), but the release was continued for the following 21 days. Thus, the sustained release of rhBMP-2 from the composite was verified. ALP staining results showed nHAp with rhBMP-2 contributed better on differentiation than nHAp itself. µCT and histology demonstrated that spinal fusion was achieved either one or both transverse processes in almost all BMP 3µg and BMP 10µg treated animals. On the contrary, only small or no bone formation was observed in the BMP0µg group (bilateral non-union / unilateral fusion/ bilateral fusion, BMP0µg group; 9/0/0, BMP3µg group; 1/0/11, BMP10µg group; 0/1/11).

We developed a new technology for bone regeneration with BMP-2/PLA-PEG/nHAp composite. With this composite, the required dose of BMP-2 for spinal fusion in rats (10µg) was decreased to 1/3 (3µg) which can be explained by the superior properties of nano-sized hydroxyapatite and by the achievement of sustainable release of rhBMP-2 from the composite.

This study is supported by Japanese Society of the Promotion of Science (JSPS) and Scientific and Technological Research Council of Turkey (TUBITAK). [Project No: 215S834]


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 42 - 42
1 Dec 2020
Özkan Ö Karaçoban L Dönmez G Korkusuz F
Full Access

Adductor strain is a common injury among football players. The adductor muscle group contains the three adductor muscles. (adductor longus, magnus and brevis) Adductor longus muscle is a triangular-shaped long muscle. This muscle originates from the superior ramus of the pubic bone and inserted into the middle part of the linea aspera. Adductor longus muscle is the most commonly injured muscle of adductors. Sudden acceleration, jumping, stretching, and kicking the ball are common causes of an adductor injury. Adductor muscle strains can result in missed playing time for football players.

We present a 26-year-old man soccer player with pain in the left groin and proximal thigh. The symptoms had started during training and after kicking the ball with left foot (dominant side), he felt an acute pain in the groin region and proximal thigh. Despite the injury, he managed to finish the training. The team physician examined the patient immediately after training. The range of motion of both hip joints was in normal ranges and mild pain with adduction. There was a palpable mass at the inner proximal thigh during contraction of adductor muscles. There was no history of groin pain or adductor problems before this injury. Conventional radiographs showed no osseous abnormalities. 36 hours after the injury, MRI revealed acute grade IIB strain in the left adductor longus muscle, including both superior and inferior parts of the muscle. A hematoma was observed in the superior part of the left adductor muscle, with a craniocaudal length of 42 millimeters. There was an adductor muscle strain with hyperintensity extending for a craniocaudal length of approximately 12 centimeters involving more than 50% crosses sectional diameter of the muscle belly. Conservative treatment started immediately, consisting of cold therapy and soft tissue massage. Compression of the injured tissue using a 15-cm elastic bandage roll is done to limit bleeding and provide support. Iced water machine (Game Ready) was used. The team physician examined the player every day and prescribed physiotherapy protocol daily. Additionally, short interval follow-up MRI is used to evaluate the injury. (After 7 and 14 days of the injury) No injection was performed. The player is able to return to play immediately, despite MRI's strain images. The player started straight running 5 days later and joined to team training 8 days later and played 90 minutes-league-match 12 days after injury without any pain. No injection was performed. The player is able to return to play immediately, despite MRI's strain images. The player started straight running 5 days later and joined to team training 8 days later and played 90 minutes-league-match 12 days after injury without any pain.

MRI is a useful technique in diagnosing trauma in football players presenting with groin pain. In this case, to estimate time-to-return-to-play, MRI alone is not strong evidence. MRI is a good option for follow up, but anamnesis and clinical examination is not inferior to diagnostic imaging.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 44 - 44
1 Dec 2020
Torgutalp ŞŞ Korkusuz F
Full Access

Background

Although there are predictive equations that estimate the total fat mass obtained from multiple-site ultrasound (US) measurements, the predictive equation of total fat mass has not been investigated solely from abdominal subcutaneous fat thickness. Therefore, the aims of this study were; (1) to develop regression-based prediction equations based on abdominal subcutaneous fat thickness for predicting fat mass in young- and middle-aged adults, and (2) to investigate the validity of these equations to be developed.

Methods

The study was approved by the Local Research Ethics Committee (Decision number: GO 19/788). Twenty-seven males (30.3 ± 8.7 years) and eighteen females (32.4 ± 9.5 years) were randomly divided into two groups as the model prediction group (19 males and 12 females) and the validation group (8 males and 6 females). Total body fat mass was determined by dual-energy X-ray absorptiometry (DXA). Abdominal subcutaneous fat thickness was measured by US. The predictive equations for total fat mass from US were determined as fat thickness (in mm) × standing height (in m). Statistical analyses were performed using R version 4.0.0. The association between the total fat mass and the abdominal subcutaneous fat thickness was interpreted using the Pearson test. The linear regression analysis was used to predict equations for total body fat mass from the abdominal subcutaneous fat thickness acquired by US. Then these predictive equations were applied to the validation group. The paired t-test was used to examine the difference between the measured and the predicted fat masses, and Lin's concordance correlation coefficient (CCC) was used as a further measure of agreement.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 28 - 28
1 Nov 2018
Bal Z Kaito T Ishiguro H Korkusuz P Dede E Korkusuz F
Full Access

Sustained release of BMP-2 is reported to be able to reduce the required dose of BMP-2 for bone induction. Nanohydroxyapatite (nHAp) has an osteoinduction capability which is lack in conventional hydroxyapatite. In this study, we combined PLA-PEG with nHAp and investigated the bone regenerative capacity of the newly established composite material of rhBMP-2/PLA-PEG/nHAp in a rat model of spinal fusion. The PLA-PEG was liquidized in acetone and mixed with nHAp and rhBMP-2. The sheet-shaped BMP-2/PLA-PEG (5mg)/nHAp (12.5mg) composites were prepared while evaporating the acetone. The release kinetics of rhBMP-2 from the composite was investigated by ELISA. In vivo bone formation was investigated by posterolateral spinal fusion in rats (the dosage of rhBMP-2; 0µg/ 0.5µg / 3µg). Bone formation was assessed by µCT and histology at post-op. 8 weeks. The composite showed the burst-release in the initial 24 hours (69% of total release) and the subsequent sustained-release for 25 days. According to µCT and histology of the spinal fusion experiment for all groups the bone formation was observed. While no bony bridging was observed in 0 µg and 0.5 µg BMP groups; in 3 µg group bony bridging and fusion were achieved. We developed a new technology for bone regeneration with rhBMP-2/PLA-PEG/nHAp composite. The reduction in the required dose of BMP-2 for bone induction was achieved. This result can be explained by the high bone induction ability of nHAp and sustainable release of BMP from PLA-PEG in the composite.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 63 - 63
1 Nov 2018
Kose N Köse A Bayrak C Sevencan A Akyürekli A Koparak T Korkusuz F Dogan A
Full Access

Long-term survival and favourable outcome of implant use are determined by bone-implant osseointegration and absence of infection near the implants. As with most diseases, prevention is the preferred approach. Silver ion doped calcium phosphate based ceramic coating (Silveron®) for implant coating has been shown previously to be a potent antimicrobial agent as indicated by in vitro testing. The present study reports on clinical experience using silver ion doped calcium phosphate based ceramic coated external fixator pins as surgical treatment in the management of chronic osteomyelitis and open fractures. Ten patients had external fixators: six for open fractures of ankle, three for chronic osteomyelitis of the femur, one for tibia pseudoarthrosis. The electrospray method was used for coating the external fixator pins with silver ion doped calcium phosphate-based ceramics. A radiofrequency energy source was used to sinter the coated pins. Microbiological, roentgenographic, toxic and biochemical analyzes of patients were carried out. Wound debridement, and subsequent wound care resulted in control of the infection in three chronic osteomyelitis and in healing of seven fractures after follow-up ranging from three to six months. In total 67 pins were used in 10 patients but only one pin was positive microbiologically in one patient. Collectively, these data clearly illustrate that the toxic effects of silver were not observed at the doses used. Silver ion doped calcium phosphate based ceramic coating (Silveron®) can be used to prevent infection associated with the implant.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 85 - 85
1 Apr 2018
Taş S Korkusuz F Erden Z
Full Access

Purpose

Even though various factors have been associated with neck pain, skeletal muscle mechanical properties have been cited among the leading causes of neck pain. Changes in skeletal muscle stiffness may be related to chronic neck pain and these changes may be associated with the severity of pain and disability in patients with chronic neck pain. The purpose of the present study was to investigate differences in neck muscle stiffness between patients with chronic neck pain and asymptomatic control group. Another purpose of the study was to investigate the relationship of muscle stiffness with the severity of physical disability and pain in patients with chronic neck pain.

Methods

A cross-sectional case-control study with 86 participants (43 patients with chronic neck pain and 43 age-matched asymptomatic controls) was designed. The present study included patients with a pain intensity level of 20 or more based on the Numerical Rating Scale (NRS) and a total disability level of 10 or more based on the Neck Disability Index (NDI). Ultrasonic evaluation of upper trapezius, splenius capitis, and sternocleidomastoid muscle performed with the ACUSON S3000 Ultrasonography Device using Siemens 9L4 (4–9 MHz) linear-array ultrasound probe. Shear Wave Velocity (SWV) of selected muscles was obtained using customized software, Virtual Touch Imaging and Quantification® (Siemens Medical Solution, Mountain View, CA, USA).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 94 - 94
1 Jan 2017
Tas S Yilmaz S Onur M Korkusuz F
Full Access

Obesity decreases patellar tendon stiffness in females but not males Introduction Patellar tendon (PT) injuries are frequent due to excessive mechanical loading during strenuous physical activity. PT injury incidence is higher in females and obese individuals. The reason behind higher tendon injury incidence in females and obese individuals might be structural changes in tendons such as stiffness or elasticity. Tendon stiffness can recently be quantified using shear wave elastography (SWE). We aimed to examine the stiffness of PT in healthy sedentary participants using this new technology.

This prospective study was carried out with 58 (34 female, 24 male) healthy sedentary participants between the ages of 18–44 years (27.5±7.7 years). Body mass and body fat percentage were measured with the Bioelectrical Impedance method using Tanita BC-418 MA Segmental Body Composition Analyser (Tanita Corporation, Tokyo, Japan). Participants were subsequently categorized into ‘normal-weight’ (BMI < 23 kg/m2) and ‘obese’ (BMI>27.5 kg/m2). SWE of the PT was measured with the ACUSON S3000 (Siemens Medical Solution, Mountain Wiew, CA, USA) ultrasound device using the Siemens 9L4 (4–9 MHz) linear-array probe with the Virtual Touch Imaging Quantification® method. The measurement was performed by placing the US probe longitudinally on patellar tendon with knee flexed at 30°. The region between about 1 cm distal of patellar bone-tendon junction and 1 cm proximal of bone-tendon junction of tibia was used for PT stiffness measurement (Figure 1). Average of three successive measurements at 10 sec intervals was recorded as PT stiffness. PT stiffness was quantified with MATLAB Version 2015 (Mathworks, Massachusetts, USA) by converting colour data into numbers.

PT stiffness, in males, in females, in normal males, in obese males, in normal females, and in obese females was 8.6±1.0 m/sec, 7.4±1.1 m/sec, 8.6±1.1 m/sec, 8.5±1.0 m/sec, 7.9±0.9 m/sec, and 6.2±0.9 m/sec, respectively. Average body fat percentage in males, in females, in normal males, in obese males, in normal females, and in obese females was 20.1±7.4 kg/m2, 30.1±8.1 kg/m2, 15.4±5.2 kg/m2, 24.7±4.6 kg/m2, 25.6±5.5 kg/m2, and 38.1±5.0 kg/m2, respectively. Males PT stiffness was higher when compared to that of females (p=0.000). PT stiffness was similar in obese and normal males (p=0.962) but obese females had lower PT stiffness compared to normal females (p=0.001).

PT stiffness of females was lower than males and obesity decreased PT stiffness in females but not in males. The possible explanation of lower PT stiffness in females might be due to their higher estrogen levels that lead to a decrease in estradiol level and collagen synthesis. Lower tendon stiffness in obese females might be metabolic effects due to the increased adipose tissue that contains proteins such as adipokinome, chemerin, lipocalin 2, serum amyloid A3 and adiponectin. These proteins lead to disturbance of tendon homeostasis and decreased collagen content. Altered tendon homeostasis and decreased collagen content may lead to a decrease in tendon stiffness. Decreased PT stiffness in especially in obese women might be associated with increased risk of PT injury.