Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Trauma

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 380 - 380
1 Sep 2012
Meyer D Snedeker J Koch P Weinert-Aplin R Farshad M
Full Access

Introduction

ACL reconstruction using hamstring tendons has gained general acceptance. However, it has been recommended to seek a tight fit of the tendon in the bone canal in order to provide circumferential contact and healing of the graft, and to prevent secondary tunnel widening. Recent findings show, that the graft dynamically adapts to pressure in the canal resulting in a potentially loose graft-bone contact. It was the goal of this study to understand the viscoelastic behaviour of hamstring grafts under pressure and to develop a new method for tendon pre-conditioning to reduce the graft volume before implantation, in order to reduce the necessary bone canal diameter to accommodate the same graft.

Material and Methods

Flexor digitorum tendons of calf and extensor digitorum tendons of adult sheep were identified to be suitable as ACL grafts substitutes for human hamstring tendons in vitro. The effect of different compression forces on dimensions and weight of the grafts were determined. Further, different strain rates (1mm/min vs 10mm/min), compression methods (steady compression vs. creep) and different compression durations(1, 5, 10min) were tested to identify the most effective combination to reduce graft size by preserving its macroscopic structure.