header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 126 - 126
1 Apr 2019
Elliott MT King R Wang X Qureshi A Vepa A Rahman U Palit A Williams MA
Full Access

Background

Over 10% of total hip arthroplasty (THA) surgeries performed in England and Wales are revision procedures1. Malorientation of the acetabular component in THA may contribute to premature failure. Yet with increasingly younger populations receiving THA surgery (through higher incidences of obesity) and longer life expectancy in general, the lifetime of an implant needs to increase to avoid a rapid increase in revision surgery in the future.

The Evaluation of X-ray, Acetabular Guides and Computerised Tomography in THA (EXACT) trial is assessing the pelvic tilt of a patient by capturing x-rays from the patient in sitting, standing and step-up positions. It uses this information, along with a CT scan image, to deliver a personalised dynamic simulation that outputs an optimised position for the hip replacement. A clinical trial is currently in place to investigate how the new procedure improves patient outcomes2.

Our aim in this project was to assess whether accurate functional assessment of pelvic tilt could be further obtained using inertial measurement units (IMUs). This would provide a rapid, non-invasive triaging method such that only patients with high levels of tilt measured by the sensors would then receive the full assessment with x-rays.

Methods

Recruited patients were fitted with a bespoke device consisting of a 3D-printed clamp which housed the IMU and fitted around the sacrum area. A wide elastic belt was fitted around the patient's waist to keep the device in place. Pelvic tilt is measured in a standing, flexed seated and step-up position while undergoing X-rays with the IMU capturing the data in parallel. Patients further completed another five repetitions of the movements with the IMU but without the x-ray to test repeatability of the measurements. Statistical analysis included measures of correlation between the X-ray and IMU measurements.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 71 - 71
1 Aug 2013
King R Ikram A
Full Access

Purpose of study:

To assess the effectiveness of a novel locked intra-medullary device in the treatment of acute clavicle shaft fractures.

Description of methods:

Patients admitted with midshaft clavicle fractures were assessed for inclusion in the study. Inclusion criteria were mid shaft clavicle fractures with 100% displacement; more than 1, 5 cm of shortening or containing a displaced butterfly segment. Fractures were assessed for suitability to intra-medullary fixation (fracture distance from the medial and lateral end of the clavicle, medullary diameter and fracture type). 35 patients were treated operatively using the device by the author. Post-op, patients were kept in a master sling for a period of 6 weeks and followed up for a period of at least 3 months. Fracture reduction, fracture progression to union, scar size, Dash score, Constant Shoulder score, patient satisfaction and complications were assessed at follow-up by the surgeon, a radiologist and an occupational therapist.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 5 - 5
1 Mar 2013
King R Ikram A
Full Access

Background

This is a continued assessment of the effectiveness of a locked intramedullary device in the treatment of acute clavicle shaft fractures. Results of patients treated thus far were assessed, including patients reported on previously.

Description of methods

Patients admitted with midshaft clavicle fractures were assessed to determine whether operative fixation of the fracture was required. Indications for surgery were midshaft clavicle fractures with 100% displacement; more than 1.5 cm of shortening, presence of a displaced butterfly segment, bilateral clavicle fractures, ipsilateral displaced glenoid neck fractures, skin and neurovascular compromise. Patients that matched the criteria for surgery were treated operatively with an intramedullary locked device by the author. Post-operatively, patients were kept in a shoulder immobilizer for a period of 6 weeks. Patients were invited to attend a scheduled follow-up visit where the data was collected that comprised the review. All patients were assessed by the surgeon, a radiologist, a physiotherapist and an occupational therapist. Scar size and quality, Dash score, Constant Shoulder score, complications and the radiological picture were assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 4 - 4
1 Mar 2013
King R Scheepers S Ikram A
Full Access

Purpose

Intramedullary fixation of clavicle fractures requires an adequate medullary canal to accommodate the fixation device used. This computer tomography anatomical study of the clavicle and its medullary canal describes its general anatomy and provides the incidence of anatomical variations of the medullary canal that complicates intramedullary fixation of midshaft fractures.

Methods

Four hundred and eighteen clavicles in 209 patients were examined using computer tomography imaging. The length and curvatures of the clavicles were measured as well as the height and width of the clavicle and its canal at various pre-determined points. The start and end of the medullary canal from the sternal and acromial ends of the clavicle were determined. The data was grouped according to age, gender and lateralization.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 39 - 39
1 Mar 2013
Westacott D McArthur J King R Foguet P
Full Access

The orientation of the acetabular component in metal-on-metal hip resurfacing arthroplasty affects wear rate and hence failure. Correct assessment of acetabular orientation is key in assessing the painful hip resurfacing. This study aimed to establish if interpretation of pelvic radiographs with TraumaCad software can provide a reliable alternative to computed tomography (CT) in measuring the acetabular inclination and version.

TraumaCad was used to measure the acetabular orientation on AP pelvis radiographs of 14 painful hip resurfacings. Four orthopaedic surgeons performed each measurement twice. These were compared with measurements taken from CT reformats performed by an experienced musculoskeletal radiologist. The correlation between TraumaCad and CT was calculated, as was the intra- and inter-observer reliability of TraumaCad.

There is strong correlation between the two techniques for the measurement of inclination and version (p<0.001). Intra- and inter-observer reliability of TraumaCad measurements are good (p<0.001). Mean absolute error for measurement of inclination was 2.1°. TraumaCad underestimated version compared to CT in 93% of cases, by 12.6 degrees on average.

When assessing acetabular orientation in hip resurfacing, the orthopaedic surgeon may use TraumaCad in the knowledge that it correlates well with CT and has good intra- and inter-observer reliability but underestimates version by 12° on average. This underestimation may be contributed to by the natural divergence of the X-ray beam, the short arc of the ellipse left exposed by the large diameter head, and the non-hemispherical resurfacing cup.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 6 - 6
1 Mar 2013
King R Ikram A
Full Access

Background

This is an epidemiological study of patients with middle third clavicle fractures presenting to a tertiary hospital. The data is used to formulate a classification system for middle third clavicle fractures based on fracture configuration and displacement.

Description of methods

Patients presenting primarily to a referral hospital with middle third clavicle fractures were identified using the PACS radiology system. The radiographs were reviewed to determine the fracture type, displacement, shortening and amount of comminution. The clinical notes of each patient were reviewed to determine the mechanism of injury, soft tissue status, neurovascular status and treatment rendered. A novel classification system was developed to describe the different fracture configurations seen in the group. The interobserver and intraobserver correlation of the classification system as well as the ability of the classification system to predict treatment were tested.