Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 69 - 69
1 Dec 2015
Williams R Kotwal R Roberts-Huntley N Khan W Morgan-Jones R
Full Access

At first-stage revision surgery for infection of total knee arthroplasties, antibiotic-impregnated cement spacers are frequently implanted. Two types of cement spacers are commonly used, “static” and “articulating” cement spacers. Advocates of cement spacers state that they deliver high doses of antibiotics locally, increase patient comfort, allow mobility and provide joint stability. They also minimize contracture of collateral ligaments, thereby facilitating re-implantation of a definitive prosthesis at a later stage. The use of these cement spacers, however, are not without significant complications, including patella tendon injuries.

We describe a series of three patients who sustained patella tendon injuries in infected total knee arthroplasties following the use of a static cement spacer at first-stage knee revision.

The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12–20

Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 66 - 66
1 Dec 2015
Khan W Williams R Metah A Morgan-Jones R
Full Access

Honey has been used as a topical antiseptic for at least 5,000 years. SurgiHoney is a CE licensed sterile product, which has been proven to be non-toxic and effective when used topically in the treatment of chronically infected wounds. The key difference from other medical grade honey is the broad spectrum antimicrobial characteristics with activity against Gram +ve, Gram –ve and multi-resistant organisms. Its novel role against the bacterial bioburden and biofilm associated with periprosthetic infections around total knee arthroplasties (TKA's) is therefore considered.

SurgiHoney was used as an implant coating immediately prior to wound closure after implantation of salvage endoprosthesis for multiply revised, infected TKA's undergoing staged reconstruction.

We report a consecutive series of multi-revised, infected revision TKA's where SurgiHoney was used as an active antimicrobial coating. We discuss its intra-operative application and early clinical outcomes.

The use of Surgihoney as a novel anti-microbial is established in the management of complex wound infections. This is the first reported use of SurgiHoney as a deep, implant coating in the salvage of prosthetic joint infection.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2015
Williams R Khan W Huntley N Morgan-Jones R
Full Access

Joint degeneration may make a total knee arthroplasty (TKA) a requirement for pain relief and function. However, the presence of ipsilateral limb osteomyelitis (OM) makes surgical management extremely challenging.

We report the experience of a high volume revision knee surgeon managing ipsilateral limb multi resistant OM and the outcome of subsequent TKA.

Four consecutive patients were identified who had either ipsilateral femoral or tibial chronic osteomyelitis treated prior to undergoing TKA. Surgery to eradicate the osteomyelitis involved a Lautenbach compartmental debridement, and where necessary, healing by secondary intention. The decision to proceed to a TKA was based on history, clinical examination and radiological findings of advanced osteoarthritic change.

The patients had a mean age of 50 years. They had a background of multi-organism OM and underwent single-stage TKAs at an average of 63 months following eradication of the underlying OM.

Three patients did well but had complications associated with poor skin and soft tissues, and abnormal bone anatomy. One patient developed an infection and following a re-revision had an arthrodesis.

The results for the four cases are summarised in Table 1.

We have highlighted that patients with ipsilateral limb multi resistant OM are a difficult cohort to manage.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 51 - 51
1 Dec 2015
Williams R Khan W Williams H Abbas A Mehta A Ayre W Morgan-Jones R
Full Access

A common step to revision surgery for infected total knee replacement (TKR) is a thorough debridement. Whilst surgical and mechanical debridement are established as the gold standard, we investigate a novel adjuvant chemical debridement using an Acetic Acid (AA) soak that seeks to create a hostile environment for organisms, further degradation of biofilm and death of the bacteria.

We report the first orthopaedic in vivo series using AA soak as an intra-operative chemical debridement agent for treating infected TKR's. We also investigate the in vitro efficacy of AA against bacteria isolated from infected TKR's.

A prospective single surgeon consecutive series of patients with infected TKR were treated according to a standard debridement protocol. Patients in the series received sequential debridement of surgical, mechanical and finally chemical debridement with a 10 minute 3% AA soak.

In parallel, we isolated, cultured and identified bacteria from infected TKR's and assessed the in vitro efficacy of AA. Susceptibility testing was performed with AA solutions of different concentrations as well as with a control of a gentamicin sulphate disc. The effect of AA on the pH of tryptone soya was also monitored in an attempt to understand its potential mechanism of action.

Physiological responses during the AA soak were unremarkable. Intraoperatively, there were no tachycardic or arrythmic responses, any increase in respiratory rate or changes in blood pressure. This was also the case when the tourniquet was released. In addition, during the post-operative period no increase in analgesic requirements or wound complications was noted. Wound and soft tissue healing was excellent and there have not been any early recurrent infections at mean of 18 months follow up.

In vitro, zones of inhibition were formed on less than 40% of the organisms, demonstrating that AA was not directly bactericidal against the majority of the clinical isolates. However, when cultured in a bacterial suspension, AA completely inhibited the growth of the isolates at concentrations as low as 0.19%v/v.

This study has shown that the use of 3% AA soak, as part of a debridement protocol, is safe. Whilst the exact mechanism of action of acetic acid is yet to be determined, we have demonstrated that concentrations as low as 0.19%v/v in solution in vitro is sufficient to completely inhibit bacterial growth from infected TKR's.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 42 - 42
1 Sep 2012
Smitham P Khan W Hazlerigg A Bajaj S McCarthy I Calder P
Full Access

Introduction

Patients undergoing limb reconstruction with the Taylor Spatial Frame (TSF) often perceive that their frame is loose due to the rattle they hear when mobilising. Our aim was to determine how much and where this movement is in the various frame/bone constructs currently on the market.

Method

Using standard tibial saw bones three frames (TSF, Ilizarov and Hexapod) were made in an identical fashion. Constructs were cyclically loaded 4 times to 200 N in tension and compression using the Instron MTS. This was repeated three times. A seventh strut was also placed in the TSF construct and the tests repeated. Bones were then removed and the tests repeated for the frames alone.