One of the main surgical goals when performing a total knee replacement (TKR) is to ensure the implants are properly aligned and correctly sized; however, understanding the effect of alignment and rotation on the biomechanics of the knee during functional activities is limited. Cardiff University has unique access to a group of local patients who have relatively high frequency of poor alignment, and early failure. This provides a rare insight into how malalignment of TKR's can affect patients from a clinical and biomechanical point of view to determine how to best align a TKR. This study aims to explore relationship clinical surgical measurements of Implant alignment with in-vivo joint kinematics. 28 patient volunteers (with 32 Kinemax (Stryker) TKR's were recruited. Patients undertook single plane video fluoroscopy of the knee during a step-up and step-down task to determine TKR in-vivo kinematics and centre of rotation (COR). Joint Track image registration software (University of Florida, USA) was used to match CAD models of the implant to the x-ray images. Hip-Knee-Ankle (HKA) was measured using long-leg radiographs to determine frontal plane alignment. Posterior tibial slope angle was calculated using radiographs. An independent sample t-test was used to explore differences between neutral (HKA:-2° to 2°), varus (≥2°) and valgus alignment (≤-2°) groups. Other measures were explored across the whole cohort using Pearson's correlations (SPSS V23). There was found to be no statistical difference between groups or correlations for HKA. The exploratory analysis found that tibial slope correlated with Superior/Inferior translation ROM during step up (r=−0.601, p<0.001) and step down (r=−.512, p=0.03) the position of the COR heading towards the lateral (r=−.479, p=0.006) during step down. Initial results suggest no relationship between frontal plane alignment and in-vivo. Exploratory analyses have found other relationships that are worthy of further research and may be important in optimizing function.
The diagnosis of periprosthetic joint infection may be difficult with patients presenting months or years after initial surgery with surgery-associated or haematogenously spread bacteria. Synovasure™ is a new point of care assay that measures alpha defensin produced by activated leucocytes in joints; it is licensed for the diagnosis of periprosthetic joint infections. We sought to include alpha defensin testing in a testing algorithm to improve the diagnosis of periprosthetic joint infection. An algorithm for testing patients with suspected periprosthetic joint infection was developed and agreed among knee surgeons in Gloucestershire, UK. Data was prospectively collected on all tests performed along with information on how the results of the alpha defensin test altered patient management. A sample of joint fluid was taken using aseptic technique in theatre and tested for alpha defensin production at the point of care. Samples were then referred for standard culture and selected samples for 16SrRNA PCR. 12 patients were assayed for alpha defensin in periprosthetic joint fluid during 2015. 7 patients were female, 5 male and ages ranged 64–86 years. 10 patients had a negative point of care alpha defensin test. Only 2 of these patients also had a leukeocyte esterase (LE) test performed and these were negative. The culture results from all samples were negative for both direct and enrichment cultures. 3 samples also had 16SrRNA PCR performed and these were negative. 2 patient samples tested positive for alpha defensin. LE tests were not performed. Both samples were culture negative on direct and enrichment culture however both samples were also referred for 16SrRNA PCR which detected DNA compatible with Staphylococcus caprae/capitis/ saccharolyticus/epidermidis from 1 patient and DNA with homology to Streptococcus gallolyticus/equinusI for the other. Alpha defensin testing improved the diagnosis of prosthetic joint infection. A positive alpha defensin test may be used to select patients for whom 16SrRNA PCR testing is useful in order to maximise the potential for pre-revision infection diagnosis and the planning of appropriate adjuncts such as antibiotic laden cement or calcium sulphate beads. Negative alpha defensin tests on aspirated joint fluid may avoid the need for arthroscopy and biopsy and allow planning for single stage revision surgery without concern for infection.
Wales in collaboration with the Welsh Assembly Government, has attempted to start a national ligament register. Norway is the lead in Europe for running a successful national quality knee ligament registry. As yet there is no UK wide registry encompassing all forms of knee ligament surgery. The issue has been discussed at previous society meetings, but no consensus has been reached.Aims
Introduction
To review the Five year survivorship of Kinnemax TKA performed at the NHS Treatment Cantre, Weston-Super-Mare (WSM), and compare it to a similar cohort from our institution. As part of the government's initiative to reduce waiting times for major joint surgery in Wales, the Cardiff and Vale NHS Trust (CAVOC) sent 224 patients (258 knees) to the NHS Treatment Centre in Weston-Super-Mare (WSM) for total knee arthroplasty. Controversy remains as to the unexpectedly high revision rates previously seen.Purpose
Introduction
This study aims to evaluate the accuracy of sheer off self limiting screw drivers and to assess repeatability with age. It has been reported that overzealous tightening of halo pins is associated with co-morbidity. Our unit has recently received a tertiary referral where the patient over tightened a pin leading to intracranial haematoma, hence our interest in this subject. The torque produced by six new and nine old screw drivers was tested using an Avery Torque Gauge and a Picotech data recorder. These devices are designed to produce a torque of 0.68 Nm, any greater than this is potentially hazardous. Accepted error for each device was +/− 10%. The average torque produced by the new screw drivers was 0.56 Nm with a range of 0.35–0.64 Nm (SD 0.120). The older screw drivers produced an average torque of 0.67 Nm ranging from 0.52–0.85 Nm (SD 0.123). In conclusion, sheer off self limiting screw drivers are not accurate devices. The older devices are more likely to produce a torque exceeding a safe range and therefore we would recommend the use of new devices only.
Following introduction of the second offer scheme in April 2004, Cardiff and Vale NHS Trust sent 227 patients (254 knees) to the independent sector treatment centre in Weston-Super-Mare for total knee arthroplasty. The Kinemax total knee system was used in all cases. There was a perception that there were a large number of dissatisfied patients, and a previous British Orthopaedic Association report (of a 14 case sample) questioned the quality of the surgery performed. All of the patients concerned were offered a review in order to assess the outcome. Of the 227 patients (254 knees), 77% have been reviewed (167 patients, 190 knees). 23% (59 patients, 64 Knees) have not been seen. Of these, 30 patients (34 knees) declined review on the basis that they were happy with the result of surgery. 14 Patients (15 knees) were unobtainable by post of by phone. A further 12 patients (12 knees) did not attend appointments. 3 Patients (3 Knees) had died. The total number of re-operations was 27/254, giving a re-operation rate of 10.6%. There were 21 revisions, 17 for aseptic causes (oversized components, malalignment, aseptic loosening) and 4 for infection. There were 6 secondary patella resurfacings. A life table survivorship analysis was calculated for the 254 knees. The cumulative survival rate at 3 years was 85.8%. These results are considerably worse than those reported in the current published literature. This has resulted in a significant economic impact on our service.
We present the results of a simple method of stabilisation using intramedullary K-wires without violating the articular surface.