The non-union of long bones poses a substantial challenge to clinicians and patients alike. The Ilizarov fixation system and Limb Reconstruction System (LRS), renowned for their versatility in managing complex non-unions. The purpose of this retrospective study was to assess the outcomes of acute docking with the bone peg-in-bone technique for the management of non-unions of long bones. The study seeks to evaluate its effectiveness in achieving complete bony union, preserving limb length and alignment, correcting existing deformities, and preventing the onset of new ones. A retrospective analysis of 42 patients was done with infected and non-infected non-unions of long bones who received treatment at a tertiary care hospital between April 2016 to April 2022. We utilized the Association for the Study and Application of Methods of the Ilizarov (ASAMI) scoring system to assess both bone and functional outcomes and measured mechanical lateral distal femoral angle (mLDFA) for the femur and the medial proximal tibial angle (MPTA) for the tibia.Introduction
Method
The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics. Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock.
This study was proposed to evaluate the efficacy of fibrin clot augmentation in meniscal tear using inside-out meniscal repair. A total of 35 patients with meniscus tears were operated on with inside-out meniscus repair and fibrin clot augmentation. Patients were evaluated preoperatively and postoperatively with clinical criteria, Lysholm knee scoring system, and MRI. Out of the total 35 cases, 5 cases were lost to follow up. Clinical improvement was observed in 29 out of 30 patients (96.6%). The mean Lysholm score improved significantly from 67.63 ± 6.55 points preoperatively to 92.0 ± 2.9 points postoperatively (P < 0.05) in 2 years follow-up. Follow-up MRI in all patients revealed complete healing except in 1 case where the patient presented with recurrence of symptoms such as pain and locking which resolved with partial meniscectomy. Paraesthesia in the anterior part of the knee was observed in 2 cases. (6.6%). We conclude that fibrin clot augmentation is a good cost-effective modality of treatment for repairable meniscus tears to preserve the meniscus and decrease the point contact pressure on the condyles which may prevent the early occurrence of osteoarthritis.
To evaluate the functional outcome of open humerus diaphyseal fractures treated with the Three-stitch technique of antegrade humerus nailing. This is a retrospective study conducted at the Department of Orthopaedics in D. Y. Patil University, School of Medicine, Navi Mumbai, India. The study included 25 patients who were operated on from January 2019 to April 2021 and follow-ups done till May 2022. Inclusion criteria were adult patients with open humerus diaphyseal fractures (Gustilo-Anderson Classification). All patients with closed fractures, skeletally immature patients, and patients with associated head injury were excluded from the study. All patients were operated on with a minimally invasive Three-stitch technique for antegrade humerus nailing. All patients were evaluated based on DASH score. Out of the 25 patients included in the study, all patients showed complete union. The mean age of the patients was 40.4 years (range 23–66 years). The average period for consolidation of fracture was 10.56 weeks (range 8–14 weeks). The DASH score ranged from 0 to 15.8 with an average score of 2.96. Five patients reported complications with three patients of post-operative infection and delayed wound healing and two patients with screw loosening. All complications were resolved with proper wound care and the complete union was noted. None of the patients had an iatrogenic neurovascular injury. Three-stitch antegrade nailing technique is a novel method to treat diaphyseal humerus fractures and provides excellent results. It has various advantages such as minimal invasiveness, minimal injury to the rotator cuff, fewer infection rates, minimal iatrogenic injuries, and good functional outcomes. Therefore, this treatment modality can be effectively used for open humerus diaphyseal fractures.
Osteomyelitis is an inflammatory condition accompanied by the destruction of bone and caused by an infecting microorganism. Open contaminated fractures can lead to the development of osteomyelitis of the fractured bone in 3-25% of cases, depending on fracture type, degree of soft-tissue injury, degree of microbial contamination, and whether systemic and/or local antimicrobial therapies have been administered. Untreated, infection will ultimately lead to non-union, chronic osteomyelitis, or amputation. We report a case series of 10 patients that presented with post-operative infected non-union of the distal femur with or without prior surgery. The cases were performed at Padmashree Dr. D. Y. Patil Hospital, Nerul, Navi Mumbai, India. All the patients’ consents were taken for the study which was carried out in accordance with the Helsinki Declaration. The methodology involved patients undergoing a two-stage procedure in case of no prior implant or a three-stage procedure in case of a previous implant. Firstly, debridement and implant removal were done. The second was a definitive procedure in form of knee arthrodesis with ring fixator and finally followed by limb lengthening surgery. Arthrodesis was planned in view of infection, non-union, severe arthritic, subluxated knee, stiff knee, non-salvage knee joint, and financial constraints. After all the patients demonstrated wound healing in 3 months along with good radiographic osteogenesis at the knee arthrodesis site, limb lengthening surgeries by tibial osteotomy were done to overcome the limb length discrepancy. Distraction was started and followed up for 5 months. All 10 patients showed results with sound knee arthrodesis and good osteogenesis at the osteotomy site followed by achieving the limb length just 1-inch short from the normal side to achieve ground clearance while walking. Our case series is unique and distinctive as it shows that when patients with infected nonunion of distal femur come with the stiff and non-salvage knee with severe arthritic changes and financial constraints, we should consider knee arthrodesis with Ilizarov ring fixator followed by limb lengthening surgery.
Higher uric acid levels or hyperuricemia is a product of more uric acid production, dysfunctional renal excretion, or a combination of both leading to deposition of urate crystals in the joints and kidneys and has been strongly linked with the development of gout, that is, acute inflammatory arthritis. Uric acid levels have been suggested to depend on multiple factors including lifestyle, diet, alcohol consumption, etc. As these are risk parameters for hyperuricemia and since lifestyle choices vary amongst different Indian communities, we sought to study the prevalence of hyperuricemia in these communities. Also, large-scale data (in terms of gender, age, lifestyle, community) on the prevalence of hyperuricemia in subjects amongst different community populations, Hindu, Muslim, Sikh, and Christian was generated. In a retrospective study conducted at Dr. D. Y. Patil School of Medicine & Research Centre, Navi Mumbai from April 2018 to May 2021, information was gathered from four major communities on a range of indicators including serum uric acid levels followed by a thorough multilevel logistic analysis. We evaluated uric acid levels in 10,378 patients of four different communities. Outcomes were assessed biochemically as well as clinically based on the levels of serum uric acid. The mean serum uric acid levels were highest in Sikhs (7.6 mg%, n=732) followed by Christians (7.3 mg%, n=892) and then by Hindus (5.9 mg%, n=6846) and Muslims (5.6 mg%, n=1908). About 83.7% of Christians consumed meat in a non-vegetarian diet followed by 45.7% Muslims. Percentage of Christians who binge drink were highest whereas percentage of Sikh people in the heavy drinkers’ category were 5.2%. Further, 9.5% Hindus were current smokers followed by 7.8% Sikhs who smoked at present. Overall, our study of 10,378 patients demonstrated that the serum uric acid levels varied from one Indian community to another due to varying external factors like diet, age, lifestyle, and addictions. Thus, lifestyle modification in communities with higher serum uric acid levels is highly advocated and this may reduce the healthcare burden of gouty arthritis in these communities.
Osteochondromas are benign chondrogenic lesions arising on the external surface of the bone with aberrant cartilage (exostosis) from the perichondral ring that may contain a marrow cavity also. In a few cases, depending on the anatomical site affected, different degrees of edema, redness, paresthesia, or paresis can take place due to simple contact or friction. Also, depending on their closeness to neurovascular structures, the procedure of excision becomes crucial to avoid recurrence. We report a unique case of recurrent osteochondroma of the proximal humerus enclosing the brachial artery which makes for an important case and procedure to ensure that no relapse occurs. We report a unique case of a 13-year-old female who had presented with a history of pain and recurrent swelling for 5 years. The swelling size was 4.4 cm x 3.7 cm x 4 cm with a previous history of swelling at the same site operated in 2018. CT reports were suggestive of a large well defined broad-based exophytic diaphyseal lesion in the medial side of the proximal humerus extending posteriorly. Another similar morphological lesion measuring approximately 9 mm x 7 mm was noted involving the posterior humeral shaft. The minimal distance between the lesion and the brachial artery was 2 mm just anterior to the posterio-medial growth. Two intervals were made, first between the tumor and the neurovascular bundle and the other between the anterior tumor and brachial artery followed by exostosis and cauterization of the base. Proper curettage and excision of the tumor was done after dissecting and removing the soft tissue, blood vessels, and nerves so that there were very less chances of relapse. Post-operative X-ray was done and post 6 months of follow-up, there were no changes, and no relapse was observed. Thus, when presented with a case of recurrent osteochondroma of the proximal humerus, osteochondroma could also be in proximity to important vasculature as in this case enclosing the brachial artery. Thus, proper curettage and excision should be done in such cases to avoid recurrence.
Total Knee Arthroplasty (TKA) improves the quality of life of osteoarthritic and rheumatoid arthritis patients, however, is associated with moderate to severe postoperative pain. There are multiple methods of managing postoperative pain that include epidural anesthesia but it prevents early mobilization and results in postoperative hypotension and spinal infection. Controlling local pain pathways through intra-articular administration of analgesics is a novel method and is inexpensive and simple. Hence, we assess the effects of postoperative epidural bupivacaine injection along with intra-articular injection in total knee replacement patients. The methodology included 100 patients undergoing TKA randomly divided into two groups, one administered with only epidural bupivacaine injection and the other with intra-articular cocktail injection. The results were measured based on a 10-point pain assessment scale, knee's range of motion (ROM), and Lysholm knee score. The VAS score was lower in the intra-articular cocktail group compared to the bupivacaine injection group until the end of 1-week post-administration (p<0.01). Among inter-group comparisons, we observed that the range of motion was significantly more in cocktail injection as compared to the bupivacaine group till the end of one week (p<0.05). Lysholm's score was significantly more in cocktail injection as compared to the bupivacaine group till the end of one week (p<0.05). Our study showed that both epidural bupivacaine injection and intra-articular injection were effective in reducing pain after TKA and have a comparable functional outcome at the end of 4 weeks follow up. However, the pain relief was faster in cases with intra-articular injection, providing the opportunity for early rehabilitation. Thus, we recommend the use of intra-articular cocktail injection for postoperative management of pain after total knee arthroplasty, which enables early rehabilitation and faster functional recovery of these patients.
Management of gap non-union of the tibia, the major weight bearing bone of the leg remains controversial. The different internal fixation techniques are often weighed down by relatively high complication rates that include fractures which fail to heal (non-union). Minimally invasive techniques with ring fixators and bone transport (distraction osteogenesis) have come into picture as an alternative allowing alignment and stabilization, avoiding a graduated approach. This study was focused on fractures that result in a gap non-union of > 6 cm. Ilizarov technique was employed for management of such non-unions in this case series. The Ilizarov apparatus consists of rings, rods and kirschner wires that encloses the limb as a cylinder and uses kirschner wires to create tension allowing early weight bearing and stimulating bone growth. Ilizarov technique works on the principle of distraction osteogenesis, that is, pulling apart of bone to stimulate new bone growth. Usually, 4–5 rings are used in the setup depending on fracture site and pattern for stable fixation. In this study, we demonstrate effective bone transport and formation of gap non-union more than 6 cm in 10 patients using only 3 rings construct Ilizarov apparatus. This case study was conducted at Dr. D. Y. Patil Medical Hospital, Navi Mumbai, Maharashtra, India. The study involved 10 patients with a non-union or gap > 6 cm after tibial fracture. 3 rings were used in the setup for the treatment of all the patients. Wires were passed percutaneously through the bone using a drill and the projecting ends of the wires were attached to the metal rings and tensioned to increase stability. The outcome of the study was measured using the Oxford Knee scoring system, Functional Mobility Scale, the American Foot and Ankle Score and Visual Analog Scale. Further, follow up of patients was done upto 2 years.Introduction and Objective
Materials and Methods