Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 49 - 49
1 Apr 2018
Yoo J Jung H Kim S
Full Access

Injection before total knee arthroplasty(TKA) is the one of the postoprative risk factors after TKA and Infection after TKA can result in disastrous consequences. When the duration between injection and TKA is longer than 6 months, the risk is no longer elevated. Evaluation of synovial WBC number in frozen section slide is needed to check the presence of infection in revision total knee arthroplasty. Currently many patients have a history of multiple intraarticular injection before the primary TKA. Purpose of this study is to evaluate the synovial WBC findings in primary TKA and compare between injection group and no injection group. Materials and Methods. The synovial specimen(suprapatella pouch and posterior capsule) of 68 primary total knee arthroplasty were evaluated by the pathologist and reported the number of the WBC in frozen section /5 separate high power fields(HPF) (500x).. Injection group were 37 cases and non -injection group were 31 cases. Preoperative CRP and ESR were recorded and followe-up duration was more than 2 years. Joint fluid was sent to be cultured and analysed. Results. WBC count in frozen section shoed was average 4 WBCs/HPF (range < 0∼ 25) in both specimen and the suprapatella specimen was 3 WBCs/HPW (range 0∼25) and posterior capsule specimen was 1 WBCs/HPF(range 0∼14). The WBC count of injection group was 8 (range, 0∼25) and that of no injection group was 1.2 cells (range 0∼12) (p<0.05). The WBC counts in joint fluid was average 240 cells/ml (range. 1∼300) in non injection group and 643 cells/ml(range, 50∼1000) (p<0.05). The duration from the intraarticular injection to index surgery was 9 months(range, 6 weeks∼ 7 momths). The number of injection and duration bwtween injection and operationto has no significant correlation with the WBC counts. Eight percentage of specimen showed more than 10 WBCs in injection group and these patients have been not infected after more than 24 moths after TKA. Conclusion. The WBC count of the synovium in priamry TKA with injection history for degenerative osteoarthritis is variable and we could not recommend the routine frozen section analysis in primary TKA who have a history of intraarticualr injection..


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2018
Jung H Lee D Sun M Kang H
Full Access

Background

Total ankle arthroplasty (TAA) with the use of third generation implants has demonstrated favorable clinical results and improved survival. However, few studies have compared the different types of implants. The purpose of this study was to perform a retrospective evaluation of patient outcomes and complications by comparing TAA procedures performed with HINTEGRA versus MOBILITY systems.

Methods

Fifty-two consecutively enrolled patients (28 men and 24 women; mean age 64.8 years) underwent TAA using HINTEGRA (21 ankles) or MOBILITY (33 ankles) between September 2004 and July 2012. Visual analog scale (VAS) pain scores and the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot scores were determined at each follow-up visit. The radiographs were reviewed to assess component positioning, radiolucency, heterotopic ossification and other factors.