The burden of prosthetic joint infection (PJI) in total knee arthroplasty (TKA) has been rising in line with the number of primary operations performed. Current estimates suggest an infection rate of 1–2.4%. Two-stage revision has traditionally been considered the gold standard of treatment; however, some studies suggest comparable results can be achieved with single-stage procedures. The potential advantages include less time in hospital, a single anaesthetic, reduced costs, and greater patient satisfaction. We reviewed data for 72 patients (47 males, 25 females), with a mean age of 71 years (range, 49 to 94), who underwent single-stage revision TKA for confirmed PJI between 2006 and 2016. A standardized debridement protocol was performed with immediate single-stage exchange. All cases were discussed preoperatively at multidisciplinary team (MDT) meetings, which included input from a senior musculoskeletal microbiologist. Patients were not excluded for previous revisions, culture-negative PJI, or the presence of a sinus.Introduction
Methods
Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests.INTRODUCTION
METHODS
3D preoperative planning software for anatomic and reverse total shoulder arthroplasty (ATSA and RTSA) provides additional insight for surgeons regarding implant selection and placement. Interestingly, the advent of such software has brought previously unconsidered questions to light on the optimal way to plan a case. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current glenoid implant selection and placement. 172 ASES members completed an 18-question survey on their thought process for how they select and place a glenoid implant for both ATSA and RTSA procedures. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into three cohorts based on their responses to usage of 3D preoperative planning software: high users, seldom users, and non-users. Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.INTRODUCTION
METHODS
The advent of CT based 3D preoperative planning software for reverse total shoulder arthroplasty (RTSA) provides surgeons with more data than ever before to prepare for a case. Interestingly, as the usage of such software has increased, further questions have appeared over the optimal way to plan and place a glenoid implant for RTSA. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current RTSA implant selection and placement. 172 ASES members completed an 18-question survey on their thought process for how they select and place a RTSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.INTRODUCTION
METHODS
3D preoperative planning software for anatomic total shoulder arthroplasty (ATSA) provides surgeons with increased ability to visualize complex joint relationships and deformities. Interestingly, the advent of such software has seemed to create less of a consensus on the optimal way to plan an ATSA rather than more. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current ATSA implant selection and placement. 172 ASES members completed an 18-question survey on their thought process for how they select and place an ATSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.INTRODUCTION
METHODS
In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. Specifically, obese patients have shown increased rates of infection, dislocation, need for revision, wound dehiscence, increased operative time and prolonged hospital stay. Additionally, obese TKA patients have been shown to have increased rates of aseptic loosening, thromboembolic events, wound complications, and cardiopulmonary events. Worsening severity of obesity seems to correlate with worsening outcomes and super obesity (BMI>50) has been identified as an independent risk factor for complications. Patients with BMI>35 have shown to be 6.7 times more likely to develop infection after TKA. Patients with BMI>40 have a 3.35 times higher rate of revision for deep infection than those with BMI<35. The odds ratio for major complications increases dramatically beyond BMI>45. How can we improve outcomes in the obese patient? Preoperative care for the obese patient involves nutritional counseling, incorporating weight loss methods, physical therapy, metabolic workup and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD, malnutrition, renal failure). Identifying and managing comorbidities is especially important given that some comorbidities such as malnutrition have been shown to be as strong or even stronger an independent risk factor for postoperative TJA complications than obesity. In some cases higher complications were seen which some authors attribute to bariatric patients remaining in a catabolic state after weight loss. We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and preoperative screening and management is essential in reducing complications. Although weight loss is important, bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimization to ensure successful treatment in obese TJA patients.
The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress. It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used vs. use of pulsatile saline lavage alone. Meneghini used this pressurised carbon dioxide system to study the influence of NO tourniquet use in TKA. He found a significant lowering of opioid consumption postoperatively. Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.
Variability in placement of total shoulder arthroplasty (TSA) glenoid implants has led to the increased use of 3D CT preoperative planning software. Computer assisted surgery (CAS) offers the potential of improved accuracy in TSA while following a preoperative plan, as well as the flexibility for intraoperative adjustment during the procedure. This study compares the accuracy of implantation of reverse total shoulder arthroplasty (rTSA) glenoid implants using a CAS TSA system verses traditional non-navigated techniques in 30 cadaveric shoulders relative to a preoperative plan from 3D CT software. High resolution 1mm slice thickness CT scans were obtained on 30 cadaveric shoulders from 15 matched pair specimens. Each scan was segmented and the digital models were incorporated into a preoperative planning software. Five fellowship trained orthopedic shoulder specialists used this software to virtually place a rTSA glenoid implant as they deemed best fit in six cadavers each. The specimens were randomized with respect to side and split into a cohort utilizing the CAS system and a cohort utilizing conventional instrumentation, for a total of three shoulders per cohort per surgeon. A BaSO4 PEEK surrogate implant identical in geometry to the metal implant used in the preoperative plan was used in every specimen, to maintain high CT resolution while minimizing CT artifact. The surgeons were instructed to implant the rTSA implants as close to their preoperative plans as possible for both cohorts. In the CAS cohort, each surgeon used the system to register the native cadaveric bones to each respective CT, perform the TSA procedure, and implant the surrogate rTSA implant. The surgeons then performed the TSA procedure on the opposing side of the matched pair using conventional instrumentation. Postoperatively, CT scans were repeated on each specimen and segmented to extract the digital models. The pre- and postoperative scapulae models were aligned using a best fit match algorithm, and variance between the virtual planned position of the implant and the executed surgical position of the implant was calculated [Fig 1].INTRODUCTION
METHODS
Over the last decade, sensor technology has proven its benefits in total knee arthroplasty, allowing the quantitative assessment of tension in the medial and lateral compartment of the tibiofemoral joint through the range of motion (VERASENSE, OrthoSensor Inc, FL, USA). In reversal total shoulder arthroplasty, it is well understood that stability is primarily controlled by the active and passive structures surrounding the articulating surfaces. At current, assessing the tension in these stabilizing structures remains however highly subjective and relies on the surgeons’ feel and experience. In an attempt to quantify this feel and address instability as a dominant cause for revision surgery, this paper introduces an intra-articular load sensor for reverse total shoulder arthroplasty (RTSA). Using the capacitive load sensing technology embedded in instrumented tibial trays, a wireless, instrumented humeral trial has been developed. The wireless communication enables real-time display of the three-dimensional load vector and load magnitude in the glenohumeral joint during component trialing in RTSA. In an in-vitro setting, this sensor was used in two reverse total shoulder arthroplasties. The resulting load vectors were captured through the range of motion while the joint was artificially tightened by adding shims to the humeral tray.Introduction & Aims
Method
Preoperative planning software for anatomic total shoulder arthroplasty (ATSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in ATSA. CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided three implant types: a standard non-augmented glenoid component, and an 8° and 16° posterior augment wedge glenoid component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior- posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.INTRODUCTION
METHODS
Preoperative planning software for reverse total shoulder arthroplasty (RTSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. While anatomical studies have defined the range of normal values for glenoid version and inclination, there is no clear consensus on glenoid component selection and position for RTSA. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in RTSA. CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided four glenoid baseplate implant types: a standard non-augmented component, an 8° posterior augment wedged component, a 10° superior augment wedged component, and a combined 8° posterior and 10° superior wedged augment component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior-posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.INTRODUCTION
METHODS
The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress. It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used versus use of pulsatile saline lavage alone. Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.
Total knee arthroplasty (TKA) is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity. A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity. Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS. Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leucocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment, and MARS MRI. More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11- 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimization of patient co-morbidities to help avoid preventable complications, use of pre-operative and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.
The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in total joint arthroplasty (TJA) and determine how it should be managed in order to insure good clinical outcomes. In the United States, 34.9% of adults are currently obese (BMI > 30). In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and pre-operative screening and management is essential in reducing complications. Although weight loss is important, our bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimisation to ensure successful treatment in obese TJA patients.
TKA is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/ clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity. A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity. Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS. Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leukocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment,, and MARS MRI. More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11 – 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimisation of patient comorbidities to help avoid preventable complications, use of pre- and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.
Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation; avoid IR of the femoral and ER of the tibial components; maintain correct joint line position; achieve symmetrical soft tissue balance. Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues. When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure). Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.
As the American population ages and a trend toward performing total hip arthroplasty (THA) in younger patients continues, the number of Americans undergoing THA is projected to increase over time. The advent of the bundled payment system combined with the current medical utilization climate has placed considerable pressure on surgeons to produce excellent results with early functional recovery and short hospital stays. The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in THA and determine how it should be managed. We performed a recent literature review to determine how obesity impacts outcomes in total hip arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. Our goal is to answer 3 questions: does obesity increase the complication rate in THA, if obesity matters how obese is too obese, and what must be done to improve outcomes in the obese patient? Ultimately, obesity has been shown to correlate with increased post-operative complications in THA. The arthroplasty surgeon must optimise the obese patient prior to surgery by identifying associated comorbidities and consider malnutrition screening with counseling. Notice should be taken of the degree of obesity as patients with BMI > 40 have demonstrated much higher complication rates. Strong consideration should be given to avoiding direct anterior approach in the obese patient. Healthy weight loss must be encouraged with appropriate patient counseling and treatment in order to achieve success with THA in obese patients.
The femur begins to bow anteriorly at the 200 mm level, but may bow earlier in smaller people. If the stem to be used is less than 200 mm, a straight stem can be used. If the stem is longer than 200 mm, it will perforate the anterior femoral cortex. I know this because I did this on a few occasions more than 20 years ago. To use a long straight stem, there are two techniques. One can either do a diaphyseal osteotomy or one can do a Wagner split (extended trochanteric osteotomy). Both of these will put the knee in some degree of hyperextension, probably insignificant in the elderly, but it may be of significance in the young. In very young people, therefore, it may be preferable to use a bowed stem to avoid this degree of recurvatum. There are two different concepts of loading. Diaphyseal osteotomy implies a proximal loading has been sought. The Wagner split ignores the proximal femur and seeks conical fixation in the diaphysis. There will be very little bone-bone contact between what remains of the attached femur and the detached anterior cortex so that it is important to ensure that the blood supply to the anterior cortex remains intact, preferably by using Wagner's technique, using a quarter-inch osteotome inserted through the vastus to crack the medial cortex. Current modularity is of two types. Distal modularity was attempted many years ago and was never successful. Proximal modularity, as for example, the S-ROM stem, implies various sizes of sleeves fit onto the stem to get a proximal canal fill. In mid-stem modularity, the distal stem wedges into the cone. It has to be driven into where it jams and this can be somewhat unpredictable. For this reason, the solid Wagner stem has been replaced by the mid-stem modular. Once the distal femur is solidly embedded, the proximal body is then selected for height and version. The proximal body is unsupported in the mid-stem modular and initially, few fractures were noted at the taper junction. Cold rolling, shot peening and taper strengthening seem to have solved these problems. There are a variety of types of osteotomy, which can be used for different deformities. With a mid-stem modular system, generally, all that needs to be done is a Wagner-type split and fixation is sought in the mid-diaphysis by conical reaming. No matter what stem is used, distal stability is necessary. This is achieved by flutes, which engage the endosteal cortex. The flutes alone must have sufficient rotational stability to overcome the service loads on the hip of 22 Nm. I divide revision into three categories. In type one, the isthmus is intact, i.e. the bone below the lesser trochanter so that a primary stem can be used. In type two, the isthmus is damaged, i.e. the bone below the lesser trochanter, so a long revision stem is required. In a type three, there is more than 70 mm of missing proximal femur. The Wagner stem may be able to handle this on its own, but most other stems are better supported with a structural allograft cemented to the stem. The reported long term results of mid-stem modular revision implants are good as in most, over 90% survivorship. The introduction of modularity appears to have overcome initial disadvantage of the Wagner stem, i.e. its unpredictability in terms of leg length.
Humeral radiolucent lines after anatomic TSA (aTSA) have been well described; however, little clinical consequences have been attributed to them. The recent emergence of shorter humeral stems has demonstrated higher incidences of humeral radiolucencies than has been reported historically with standard length components. This large scale database analysis quantifies and compares the clinical outcomes of aTSAs with and without radiolucent humeral lines using one specific prosthesis to determine their impact on clinical outcomes. This is a multicenter, retrospective, case controlled radiographic and clinical review. Preoperative and postoperative data was analyzed from 671 aTSA patients with a minimum of 2 years followup. 538 of these 671 aTSA patients had full radiographic followup (80.2%) and were included in this study; these patients had an average followup of 45.3 months). 459 patients had noncemented humeral stems; whereas, 79 patients had cemented humeral stems. Radiographs were reviewed at latest follow up for humeral radiolucent lines based on the technique described by Gruen et al. Patients were evaluated and scored pre-operatively and at latest follow-up using the SST, UCLA, ASES, Constant, and SPADI scoring metrics; ROM was also recorded. A Student's two-tailed, unpaired t-test was used to identify differences in pre-operative, post-operative, and improvement in results, where p<0.05 denoted a significant difference.Introduction
Methodology
As computer navigated surgery continues to progress to the forefront of orthopedic care, the application of a navigated total shoulder arthroplasty has yet to appear. However, the accuracy of these systems is debated, as well as the dilemma of placing an accurate tool in an inaccurate hand. Often times a system's accuracy is claimed or validated based on postoperative imaging, but the true positioning is difficult to verify. In this study, a navigation system was used to preoperatively plan, guide, and implant surrogate shoulder glenoid implants and fiducials in nine cadaveric shoulders. A novel method to validate the position of these implants and accuracy of the system was performed using pre and post operative high resolution CT scans, in conjunction with barium sulfate impregnated PEEK surrogate implants. Nine cadaveric shoulders were CT scanned with .5mm slice thickness, and the digital models were incorporated into a preoperative planning software. Five orthopedic shoulder specialists used this software to virtually place aTSA and rTSA glenoid components in two cadavers each (one cadaver was omitted due to incomplete implantation), positioning the components as they best deemed fit. Using a navigation system, each surgeon registered the native cadaveric bone to each respective CT. Each surgeon then used the navigation system to guide him or her through the total shoulder replacement, and implant the barium sulfate impregnated PEEK surrogate implants. Four cylindrical PEEK fiducials were also implanted in each scapula to help triangulate the position of the surrogate implants. Previous efforts were attempted with stainless steel alloy fiducials, but position and image accuracy were limited by CT artifact. BaSO4 PEEK provided the highest resolution on a postoperative CT with as little artifact as possible. All PEEK fiducials and surrogate implants were registered by probing points and planes with the navigation system to capture the digital position. A high resolution post operative CT scan of each specimen was obtained, and variance between the executed surgical plan and PEEK fiducials was calculated.INTRODUCTION
METHODS