Trabecular titanium implants are 3D printed with a high-friction ingrowth surface that is continuous with the rest of the acetabular shell. The ability to “face-change” following optimum seating of the component allows unprecedented levels of versatility in acetabular orientation. Bolt-on augments enable rapid trialling and definitive insertion of a monobloc construct. The use of these implants has rapidly increased in the National Joint Registry over the last three years with little published outcome data. We present one of the largest studies using this material. This study assesses the early stability, ingrowth and clinical outcome of revision acetabular reconstruction with trabecular titanium.Introduction
Objectives
Bone loss in the distal femur and proximal tibia is frequently encountered with both complex primary and revision knee replacement surgery. Metaphyseal sleeves provide a good option for enhanced fixation in managing such defects on both the tibia and femur. We present our results in 48 patients (50 knees) with a minimum 12 month follow up (range 12 to 45). 48 patients (50 knees) who had revision knee arthroplasty for either septic or aseptic loosening. All were graded Type II or III using the Anderson Orthopaedic Research Institute (AORI) grading system of both femoral and tibial defects. A large portion of aseptic loosening revisions were for extreme osteolysis of a bicondylar knee prosthesis.Introduction
Methods
Total hip arthroplasty (THA) in teenagers is uncommon and previously associated with poor survival rates. However it is sometimes the only option remaining to relieve pain and improve function in patients with advanced hip disease. We report on the clinical and radiological outcomes of THA in teenage patients. Medical records and radiographs of all consecutive teenage patients undergoing THA at a tertiary referral centre between 2006–2011 were reviewed. Mean follow-up was 3.4 years (range 0.6–6.8) with 9 patients having at least 5 years follow-up. Post-operative Harris hip, Oxford hip (OHS) and University of California Los Angeles (UCLA) activity scores were recorded. 51 THAs were performed in 43 patients (21 male, 22 female) with a mean age of 17 years (range 12–19). The 5 most common indications were slipped upper femoral epiphysis osteonecrosis 15 (29.4%), developmental hip dysplasia osteonecrosis 5 (9.8%), multiple/spondylo-epiphyseal dysplasia 5 (9.8%), chemotherapy-induced osteonecrosis 4 (7.8%) and idiopathic osteonecrosis 4 (8.2%). 46 (90%) were uncemented THAs and 5 (10%) were reverse hybrid THAs with 7 computer assisted design/manufacture (CADCAM) femoral implants. Articular bearings were ceramic/ceramic in 40 (78.4%), metal/metal 6 (11.8%), metal/polyethylene 3 (5.9%) and ceramic/polyethylene 2 (3.9%). The survival rate was 96% with 2 acute head revisions for 1 sciatic nerve palsy and 1 instability. Other complications (8.2%) included 1 dislocation, 1 sciatic nerve palsy that resolved, 1 surgical site infection and 1 unexplained pain. At latest follow-up, the mean Harris hip score was 90 (68–99), OHS was 42 (32–48) and UCLA activity score was 6 (4–9). Radiological analysis showed 2 patients with lucent lines around the acetabular component, but no signs of osteolysis or wear. As one of the largest studies on teenagers undergoing THA, we report good clinical and radiological outcomes at short to intermediate term follow-up.
Metal-on-Metal (MoM) hip bearings are being implanted in ever-increasing numbers and into ever-younger patients. The consequence of chronic exposure to metal ions is a cause for concern. Therefore, using cytogenetic biomarkers, we investigated a group of patients who have had MoM bearings in situ for in excess of 30 years. Whole blood specimens were obtained from an historical group of patients who have had MoM bearings in situ for in excess of 30 years. Blood was also obtained from an age and sex matched control group and from patients with Metal-on-Polyethylene (MoP) components of the same era. The whole blood was cultured with Pb-Max karyotyping medium and harvested for cytogenetics after 72 hrs. The 24 colour FISH (Fluorescent In Situ Hybridisation) chromosome painting technique was performed on the freshly prepared slides, allowing chromosomal mapping. Each slide was evaluated for chromosomal aberrations (deletions, fragments and translocations) against the normal 46 (22 pairs and two sex) chromosomes. At least 20 metaphases per sample were scored and the number of aberrations per cell calculated.Purpose
Method
Unicompartmental knee replacements (UKR) converted to total knee replacements (TKR) have often been viewed with scepticism because of the perceived difficulty of the revision and because revision procedures generally do less well than primaries. This is a prospective review of TKRs converted from a UKR between 1982 and 2000. We present the survivorship of a 77 patient cohort and the clinical results of 35 patients. All information was recorded at the time of surgery onto a database and patients have been regularly reviewed since.Background
Methods