We have reviewed 29 patients (30 hips) who had undergone revision total hip arthroplasty using a Freeman metal-backed acetabular component and acetabular impaction allografting. The mean follow-up was for 15.3 years (12 to 17). Five patients (5 hips) died with the prosthesis in situ and four (4 hips) were lost to follow-up. Twelve hips had failed and in the remaining nine there were minor symptoms. The mean time to failure requiring further surgery was nine years. Excluding patients who were lost to follow-up or had died, 72% of the hips were radiologically loose at the last review. The commonest pattern in those requiring revision was failure of the reinforcement ring in adduction with remodelling of the medial wall. Of the nine patients who had not undergone revision, one with bilateral replacements had no current radiographs and only three of the remaining seven replacements had no radiological signs of loosening. The short-term results for this technique have been reported to be satisfactory, but in the long term they are not. The factors associated with failure include the design of the prosthesis, which has been implicated in disappointing long-term results when used in primary arthroplasty, but not with the frequency of failure found in this series. It seems that the reliance on peripheral screw fixation over a bed of allograft without bridging the graft does not provide sufficient stability to allow incorporation of the graft.
Twenty-nine patients (30 hips) with uncemented acetabular impaction allografting contained behind a metal backed component screwed to the pelvis at revision hip arthroplasty were reviewed at 12 to17 years (average 15.3 years) follow up. Five patients had died with the prosthesis in situ, 4 patients were lost to follow up, 13 patients had failed requiring further revision (only one failed prior to 5 years) and 9 survivors were minimally asymptomatic. The mean time to failure warranting further surgery was 9 years. Analysis of available serial radiographs (24 cases) demonstrated signs of loosening (migration, progressive radiolucent lines, screw breakage) in 54% of the latest radiographs of all cases. Removing those lost to follow up or deceased, 72% were radiologically loose (in the intact asymptomatic group 57% could be defined as loose). Additionally, in 70% of the cases the acetabular component tended to fail in a varus manner as the medial wall remodelled. These results indicate as previously published, short term results for this technique are satisfactory but in the long term they are not. Factors associated with this include the pressfit nature of the polyethylene liner which has been implicated in disappointing long term results for this prosthesis in primary applications, but not of the level of failure encountered in the current series. This experience suggests that the reliance on screw fixation over a bed of allograft in the absence of cement supplementation does not provide sufficient stability for reliable bone graft incorporation. The method reported above should be abandoned.