Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims

Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.

Methods

Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 11 - 11
1 Aug 2018
Muirhead-Allwood S Logishetty K van Arkel R Ng G Cobb J Jeffers J
Full Access

The hip joint capsular ligaments (CL) passively restrain extreme range of motion (ROM) by wrapping around the native femoral head, and protect against impingement, edge loading wear and dislocation. This study compared how ligament function was affected by device (hip resurfacing arthroplasty, HRA; dual mobility total hip arthroplasty, DM-THA; and conventional THA, C-THA), with and without CL repair. It was hypothesized that ligament function would only be preserved when native anatomy was preserved: with restoration of head-size (HRA or DM-THA) and repair.

Eight normal male cadaveric hips were skeletonised, retaining the hip capsule. CL function was quantified by measuring ROM by internally (IR) and externally rotating (ER) the hip in six functional positions, ranging from full extension with abduction to full flexion with adduction (squatting). Native ROM was compared to ROM after posterior capsulotomy and HRA, and C-THA and DM-THA, before and after surgical CL repair.

ROM increased most following C-THA (max 62°), then DM-THA (max 40°), then HRA (max 19°), indicating later engagement of the capsule and reduced biomechanical function with smaller head-size. Dislocations also occurred in squatting after C-THA and DM-THA. CL-repair following HRA restored ROM to the native hip (max 8°). CL-repair following DM-THA reduced ROM hypermobility in flexed positions only and prevented dislocation (max 36°). CL-repair following C-THA did not reduce ROM or prevent dislocation.

When HRA was combined with repair, native anatomy was preserved and ligament function was restored. For DM-THA with repair, ligament function depended on the movement of the mobile bearing resulting in near-native function in some positions, but increased ROM when ligaments were unable to wrap around the head/neck. Following C-THA, the reduced head-size resulted in inferior capsular mechanics in all positions as the ligaments remained slack, irrespective of repair.

Choosing devices with anatomic head-sizes (resurfacing or dual-mobility) and repairing the capsular ligaments may protect against instability in the early postoperative period.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 4 - 4
1 Aug 2018
Cobb J Clarke S Halewood C Wozencroft R Jeffers J Logishetty K Keane B Johal H
Full Access

We aimed to demonstrate the clinical safety of a novel anatomic cementless ceramic hip resurfacing device. Concerns around the safety of metal on metal arthroplasty have made resurfacing less attractive, while long term function continues to make the concept appealing. Biolox Delta ceramic is now used in more than 50% of all hip arthroplasties, suggesting that it's safety profile is acceptable. We wondered if a combination of these concepts might work?

The preclinical testing of anatomic hip resurfacing device developed by our group was presented last year. A twenty patient safety study was designed. Patients had to be between the ages of 18 and 70. The initial size range was restricted to femoral heads between 46 and 54, representing the common sizes of hip resurfacing. The primary outcomes were clinical safety, PROMs and radiological control. Secondary outcomes include CTRSA and metal ion levels.

20 patients were recruited, aged 30–69. 7 were women and 13 were men. There were no operative adverse events in their operations undertaken between September 2017 and February 2018. One patient had a short episode of atrial fibrillation on the second postoperative day, and no other complications. At three months the median oxford hip score had risen from 27 (range 14–38) to 46 (31–48). Cobalt and chromium levels were almost undetectable at 3 months. Fixation appeared satisfactory in all patients, with no migration detected in either component. CTRSA is in process.

The initial safety of a novel cementless ceramic resurfacing device is demonstrated by this data. The 10 year, 250 case efficacy study will continue in 5 other European centres.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 29 - 29
1 Jan 2018
Cobb J Clarke S Jeffers J Wozencroft R Halewood C Amis A
Full Access

Hip resurfacing remains a safe and effective option according to registry data. Results in women were less reliable, in part owing to soft tissue impingement. Biolox Delta ceramic bearing couples are now in widespread use with very low complication rates. We set about merging these three elements to develop a novel hip resurfacing arthroplasty.

Contours of both acetabular and femoral components were generated from biometric data, adapted to the constraints of ceramic machining, to ensure that radii blended from the bearing surface avoiding any sharp boundaries. Plasma spray coating with titanium and hydroxyapatite direct onto ceramic was developed and tested using shear, tensile and taber abrasion testing. Wear testing was carried out to 5 million cycles according to the ASTM. Destructive testing was carried out in a variety of test conditions and angles.

Cadaveric testing demonstrated stability using a single use disposable instruments for both conventional and patient specific procedures. Very low dose CT enabled the entire interface to be observed as the Ceramic is radiolucent, enhancing migration analysis, which will be undertaken at 4 intervals to confirm stability. Functional scores and gait analysis will be used in the safety study.

The CE study recruitment is underway, with first in human trials starting in summer 2017. PMA submission will follow the safety study. Commercial release of the device in Europe is unlikely before 2019, and in the USA may not be until 2027. The path to novel device development in 2017 is very costly in time and money.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 62 - 62
1 Jan 2018
Muirhead-Allwood S Jeffers J
Full Access

The hip joint capsule passively restrains extreme range of motion protecting against impingement, dislocation and possibly edge loading. These functions would be advantageous following total hip arthroplasty (THA) however the degree of capsular excision, preservation and/or repair greatly varies between surgeons/approaches. Therefore, we asked: how does THA affect capsular ligamentous biomechanics? Which factors have the biggest influence?

For this laboratory based, cadaveric model, THA was performed through the acetabular medial wall, thus preserving the entire hip capsule. A previously published testing rig was used to measure capsular function by internally and externally rotating the hip in each of five hip positions (standing, sitting, gait heel strike, and two impingement risk positions, full flexion with adduction & extension with abduction). N=8 hips were tested both before and after THA allowing for repeated measurements between the native and replaced hip.

The ROM before the capsule engaged increased following THA (p<0.05), indicating reduced biomechanical function. Internal rotation was affected more than external rotation. Increasing neck length restored the ROM more towards the native condition. Increasing head size also had a small positive effect, but less than neck length.

Following THA, the capsular ligaments were no longer able to wrap around the smaller femoral head thereby limiting their ability to restrain excessive hip movement. The anterior capsule is affected less than the posterior, and may benefit from being preserved length. A repair to the posterior capsule should compensate for the reduced THA head size in order to restore function.