The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.Aims
Methods
The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.Aims
Methods
Single-stage revision total knee arthroplasty (rTKA) is gaining popularity in treating chronic periprosthetic joint infections (PJIs). We have introduced this approach to our clinical practice and sought to evaluate rates of reinfection and re-revision, along with predictors of failure of both single- and two-stage rTKA for chronic PJI. A retrospective comparative cohort study of all rTKAs for chronic PJI between 1 April 2003 and 31 December 2018 was undertaken using prospective databases. Patients with acute infections were excluded; rTKAs were classified as single-stage, stage 1, or stage 2 of two-stage revision. The primary outcome measure was failure to eradicate or recurrent infection. Variables evaluated for failure by regression analysis included age, BMI, American Society of Anesthesiologists grade, infecting organisms, and the presence of a sinus. Patient survivorship was also compared between the groups.Aims
Methods
Unidirectional mobile bearing knees (RP) were developed to optimise the tibio-femoral articulation in an effort to enhance function and reduce polyethylene wear. The self aligning bearing should also benefit the patello-femoral joint further improving outcome. This study was designed to assess whether these potential benefits are realised in the clinical setting. A total of 352 patients undergoing a PS PFC Sigma TKR were randomly allocated to receive either a Mobile Bearing (176 knees) or a Fixed Bearing (176 knees) tibial tray. Within each group a further randomisation for patella resurfacing versus retention was included. All knees were scored using standard tools (Oxford, AKSS, Patella Score) by independent nurse specialists. At 5 year review there had been 38 deaths (19 in each group), 5 revisions (4 fixed, 1 RP), 7 late patella resurfacings (4 fixed, 3 RP) and a small number of other patients had withdrawn, leaving 142 fixed bearing knees and 144 mobile bearing knees for evaluation.Introduction
Methods