Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 20 - 20
1 Oct 2015
Mohanlal P Bawale R Samsani S Jain S Joshi A Singh B Prasad R Pillai D
Full Access

Introduction

The MHRA guidelines for metal on metal (MOM) suggest cobalt and chromium levels of more than 7ppb as potential for soft tissue reaction. However, in some patients soft tissue reaction is seen even in the presence of normal serum metal ions levels.

Methods

A prospective review of all patients who had metal-on-metal hip arthroplasty was done. Patients who had both serum metal ion levels and MARS MRI scan were included in this study.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 18 - 18
1 Oct 2015
Bawale R Samsani SR Jain S Joshi A Ahmed S Singh B Mohanlal P Pillai D Prasad R
Full Access

Background

Revision surgery for a failed metal on metal (MoM) hip arthroplasty is often unpredictable and challenging due to associated massive soft tissue and bony lesions. We present the analysis and early outcomes of revision surgery in failed MoM hip arthroplasties at our institution.

Methods

We have retrospectively analysed the findings and outcomes of revision surgery in 61 failed MoM hip arthroplasties performed between 2009 and 2014. These patients were identified in the special MoM hip surveillance pathway. All these patients underwent clinical assessment and relevant investigations. Intra-operative and histopathological findings were analysed.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 23 - 23
1 Dec 2014
Mohanlal P Jain S
Full Access

A prospective study was done to assess the outcome of MPFL reconstruction for patellar instability using quadriceps graft. MPFL reconstruction was done using superficial strip of quadriceps by an anteromedial incision and attached close to medial epicondyle of femur. There were 15 knees in thirteen patients with a mean age of 23.4 years. All patients had MPFL reconstruction and 5 had tibial tuberosity transfers. With a mean follow-up of 39.4 (12–57) months, the mean pre-op Kujala scores improved from 47.8 to 87.2. The mean Lysholm scores improved from 54.2 to 86.8. None of the patients had patella re-dislocations. MPFL reconstruction with quadriceps graft appears to be effective producing good results in patients with patellar instability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 120 - 120
1 Mar 2012
Jain S Mohanlal P Dhinsa B
Full Access

To analyse the intra-operative variation in mechanical axes of the lower limb at various stages during navigated total knee replacement.

A prospective study was performed to analyse the intra-operative variation in the mechanical axes of the lower limb during navigated total knee replacement. All consecutive patients who underwent navigated total knee replacement were included and patients with inadequate data were excluded from the study. The intra-operative initial, trial and the final mechanical hip-knee-ankle axes were recorded from the navigation system. The differences between these axes were calculated and analysed. There were forty patients, of which 24 were females and 16 males with the age ranging from 37-89 (average 68.4) years. The right knee was replaced in 27 and the left knee in 13 patients. The average initial mechanical axes alignment was 0.03° valgus (3° varus to 3° valgus), trial alignment 0.64° varus (3° varus to 1.5° valgus) and final alignment 0.25° varus (4° varus to 4° valgus). Average deviation from initial to trial axes was 0.97°, trial to final axes was 0.74° and initial to final axes was 1.08°. The correlation co-efficient between the initial and the trial axes was 0.25, trial and final axes was 0.43 & initial and final axes was 0.09.

This study highlights a significant variation in mechanical axes between the different stages of navigated total knee replacement. The potential sources of intra-operative errors causing these changes could be soft tissue imbalance, variations in implant placement and possible tracker micro motion. Execution of bony cuts in near normal neutral alignment does not guarantee achievement of near normal final alignment. We advocate surgeons to be vigilant to avoid potential malalignment during navigated total knee replacement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 117 - 117
1 Feb 2012
Melton J Jain S Kendrick B Deo S
Full Access

Background

A retrospective review of all patients transferred by helicopter ambulance to the Great Western Hospital over a 20-month period between January 2003 and September 2004 was undertaken to establish the case-mix of patients (trauma and non-trauma) transferred and the outcome of their admission and length of hospital stay.

Methods

Details of all Helicopter Emergency Ambulance Service (HEAS) transfers to this unit in the study time period were obtained from the three HEAS providers in the area and case notes for all patients (where available) were reviewed.