Since 2011, the knee service at the Nuffield Orthopaedic Centre has been offering a neutralising medial opening wedge high tibial osteotomy (HTO) to a group of patients presenting with early medial osteoarthritis of the knee, varus alignment and symptoms for more than 2 years. During development of this practice an association was observed between this phenotype of osteoarthritis and the presence of CAM deformity at the hip. A retrospective cohort study. All patients who underwent HTO since 2011 were identified (n=30). Comparator groups were used in order to establish whether meaningful observations were being made: Control group: The spouses of a high-risk osteoarthritis cohort recruited for a different study at our unit (n=20) Pre-arthroplasty group: Patients who have undergone uni-compartmental arthroplasty (UKA) for antero-medial osteoarthritis (n=20)All patients had standing bilateral full-length radiographs available for analysis using in house developed Matlab-based software for hip measurements and MediCAD for lower limb alignment measurements.Background
Methods
Prosthetic joint infection (PJI) is an uncommon but serious complication of hip and knee replacement. We investigated the rates of revision surgery for the treatment of PJI following primary and revision hip and knee replacement, explored time trends, and estimated the overall surgical burden created by PJI. We analysed the National Joint Registry for England and Wales for revision hip and knee replacements performed for a diagnosis of PJI and their index procedures from 2003–2014. The index hip replacements consisted of 623,253 primary and 63,222 aseptic revision hip replacements with 7,642 revisions subsequently performed for PJI; for knee replacements the figures were 679,010 primary and 33,920 aseptic revision knee replacements with 8,031 revisions subsequently performed for PJI. Cumulative incidence functions, prevalence rates and the burden of PJI in terms of total procedures performed as a result of PJI were calculated. Revision rates for PJI equated to 43 out of every 10,000 primary hip replacements (2,705/623,253), i.e. 0.43%(95%CI 0.42–0.45), subsequently being revised due to PJI. Around 158 out of every 10,000 aseptic revision hip replacements performed were subsequently revised for PJI (997/63,222), i.e. 1.58%(1.48–1.67). For knees, the respective rates were 0.54%(0.52–0.56) for primary replacements, i.e. 54 out of every 10,000 primary replacements performed (3,659/679,010) and 2.11%(1.96–2.23) for aseptic revision replacements, i.e. 211 out of every 10,000 aseptic revision replacements performed (717/33,920). Between 2005 and 2013, the risk of revision for PJI in the 3 months following primary hip replacement rose by 2.29 fold (1.28–4.08) and after aseptic revision by 3.00 fold (1.06–8.51); for knees, it rose by 2.46 fold (1.15–5.25) after primary replacement and 7.47 fold (1.00–56.12) after aseptic revision. The rates of revision for PJI performed at any time beyond 3 months from the index surgery remained stable or decreased over time. From a patient perspective, after accounting for the competing risk of revision for an aseptic indication and death, the 10-year cumulative incidence of revision hip replacement for PJI was 0.62%(95%CI 0.59–0.65) following primary and 2.25%(2.08–2.43) following aseptic revision; for knees, the figures were 0.75%(0.72–0.78) following primary replacement and 3.13%(2.81–3.49) following aseptic revision. At a health service level, the absolute number of procedures performed as a consequence of hip PJI increased from 387 in 2005 to 1,013 in 2014, i.e. a relative increase of 2.6 fold. While 70% of those revisions were two-stage, the use of single stage revision increased from 17.6% in 2005 to 38.5% in 2014. For knees, the burden of PJI increased by 2.8 fold between 2005 and 2014. Overall, 74% of revisions were two-stage with an increase in use of single stage from 10.0% in 2005 to 29.0% in 2014. Although the risk of revision due to PJI following hip or knee replacement is low, it is rising. Given the burden and costs associated with performing revision joint replacement for prosthetic joint infection and the predicted increased incidence of both primary and revision hip replacement, this has substantial implications for service delivery.
This study provides preliminary evidence that people with knee osteoarthritis have greater asymmetry in joint loading than healthy controls. Altered loading of the contralateral limb may signify increased risk of injury to other lower limb joints in knee osteoarthritis. Compensatory overloading of other lower limb joints is a potential reason for the non-random evolution of osteoarthritis (OA). In individuals with knee OA altered joint loading exists of the contralateral cognate joints. However, previous studies have neglected the temporal features of asymmetry in joint loading. The study aimed to identify the amount and temporal features of asymmetry in lower limb joint loading in advanced knee OA.Summary Statement
Introduction
The dGEMRIC index correlates more strongly with the pattern of radiographic joint space narrowing in hip osteoarthritis at five year follow-up than morphological measurements of the proximal femur. It therefore offers potential to refine predictive models of hip osteoarthritis progression. Longitudinal general population studies have shown that femoroacetabular impingement increases the risk of developing hip osteoarthritis, however, morphological parameters have a low positive predictive value. Arthroscopic debridement of impingement lesions has been proposed as a potential strategy for the prevention of osteoarthritis, however, the development of such strategies requires the identification of individuals at high risk of disease progression. We investigated whether delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) predicts disease progression. This imaging modality is an indirect measure of cartilage glycosaminoglycan content.Summary
Introduction
162 patient cohort with serial Metal Artefact Reduction Sequence MRI scans. Patients with normal initial scans can be followed up at 1 year. Those with abnormal scans should be followed up at a shorter interval of 6 months. Cross-sectional imaging is a key investigation in the assessment and surveillance of patients with metal-on-metal (MoM) hip arthroplasty. We present our experience of Metal Artefact Reduction Sequence (MARS) MRI scanning in metal on metal hip arthroplasty. We aimed to investigate the natural history and radiological disease progression from Adverse Reactions to Metallic Debris.Summary
Introduction
Currently, the cement being used for hemiarthroplasties and total hip replacements by the authors and many other surgeons in the UK is Palacos® (containing 0.5g Gentamicin). Similar cement, Copal® (containing 1g Gentamicin and 1g Clindamycin) has been used in revision arthroplasties, and has shown to be better at inhibiting bacterial growth and biofilm formation. We aim to investigate the effect on SSI rates of doubling the gentamicin dose and adding a second antibiotic (clindamycin) to the bone cement in hip hemiarthroplasty. We randomised 848 consecutive patients undergoing cemented hip hemiarthroplasty for fractured NOF at one NHS trust (two sites) into two groups: Group I, 464 patients, received standard cement (Palacos®) and Group II, 384 patients, received high dose, double antibiotic-impregnated cement (Copal®). We calculated the SSI rate for each group at 30 days post-surgery. The patients, reviewers and statistician were blinded as to treatment group. The demographics and co-morbid conditions (known to increase risk of infection) were statistically similar between the groups. The combined superficial and deep SSI rates were 5 % (20/394) and 1.7% (6/344) for groups I and II respectively (p=0.01). Group I had a deep infection rate 3.3 %(13/394) compared to 1.16% (4/344) in group II (p=0.082). Group I had a superficial infection rate 1.7 % (7/394) compared to 0.58% (2/344) in group II (p=0.1861). 33(4%) patients were lost to follow up, and 77 (9%) patients were deceased at the 30 day end point. There was no statistical difference in the 30 day mortality, C. difficile infection, or the renal failure rates between the two groups. Using high dose double antibiotic-impregnated cement rather than standard low dose antibiotic-impregnated cement significantly reduced the SSI rate (1.7% vs 5%; p=0.01) after hip hemiarthroplasty for fractured neck of femur in this prospective randomised controlled trial.
Femoral stem varus has been associated with poorer results. We report the incidence of varus/valgus malalignment of the Exeter polished, double taper design in a multicentre prospective study. The surgical outcomes at a minimum of five year and complication rates are also reported. A multicentre prospective study of 987 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem malalignment. The primary outcome measure was the change in the Oxford hip score (OHS) at five years. Secondary outcomes included the rate of dislocation and revision. The incidence of varus and valgus malignment were 7.1% and 2.6% respectively. There was no significant difference in OHS between neutral and malaligned femoral stems at 5 years (neutral, mean = 40.2; varus, mean 39.3, p = 0.465; valgus, mean = 40.9, p = 0.605). There was no significant difference in dislocation rate between the groups (p = 0.66). There was also no significant difference in revision rate (p = 0.34). This study provides evidence that the Exeter stem is extremely tolerant of varus and valgus malalignment, both in terms of outcome and complication rate.